Cargando…

False alarms and the positive predictive value of smartphone-based hyperacuity home monitoring for the progression of macular disease: a prospective cohort study

BACKGROUND: Home monitoring of hyperacuity allows early detection of progression in exudative neovascular age-related macular degeneration (nvAMD) and diabetic macular oedema (DMO). However, false alarms may pose a significant burden to both patients and healthcare professionals alike. PURPOSE: To a...

Descripción completa

Detalles Bibliográficos
Autores principales: Faes, Livia, Islam, Meriam, Bachmann, Lucas M., Lienhard, Kenny R., Schmid, Martin K., Sim, Dawn A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7790308/
https://www.ncbi.nlm.nih.gov/pubmed/33414531
http://dx.doi.org/10.1038/s41433-020-01356-2
_version_ 1783633395542130688
author Faes, Livia
Islam, Meriam
Bachmann, Lucas M.
Lienhard, Kenny R.
Schmid, Martin K.
Sim, Dawn A.
author_facet Faes, Livia
Islam, Meriam
Bachmann, Lucas M.
Lienhard, Kenny R.
Schmid, Martin K.
Sim, Dawn A.
author_sort Faes, Livia
collection PubMed
description BACKGROUND: Home monitoring of hyperacuity allows early detection of progression in exudative neovascular age-related macular degeneration (nvAMD) and diabetic macular oedema (DMO). However, false alarms may pose a significant burden to both patients and healthcare professionals alike. PURPOSE: To assess the false alarm rate and positive predictive value of smartphone-based home monitoring of nvAMD and DMO. METHODS: Patients treated with anti-angiogenic therapy in a pro re nata scheme for nvAMD or DMO at the Medical Retina service (Lucerne, Switzerland) between March and June 2016 were included in this prospective cohort study. The home monitoring test Alleye (Oculocare Ltd, Switzerland) provided a session score from 0–100 in addition to a traffic-light system feedback via the smartphone application. Three consecutive “red” scores were considered as a positive test or alarm signal. Specificity, 1-specificity (false alarm rate) and the predictive value for optical coherence tomography-based disease progression were analysed. RESULTS: 73 eyes of 56 patients performed 2258 tests in 222 “follow-up periods”. Progression was observed in 141 periods (63.5%). The specificity of the test was 93.8% (95% CI: 86.2–98.0%), the false alarm rate 6.1% (95% CI: 2.0–13.8%), and the positive predictive value 80.0% (95% CI: 59.3–93.2%) for the detection of progression. CONCLUSION: False alarm rates for the detection of progression in macular disease via home monitoring is low. These findings suggest that home monitoring may be a useful adjunct for remote management of nvAMD and DMO.
format Online
Article
Text
id pubmed-7790308
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-77903082021-01-08 False alarms and the positive predictive value of smartphone-based hyperacuity home monitoring for the progression of macular disease: a prospective cohort study Faes, Livia Islam, Meriam Bachmann, Lucas M. Lienhard, Kenny R. Schmid, Martin K. Sim, Dawn A. Eye (Lond) Article BACKGROUND: Home monitoring of hyperacuity allows early detection of progression in exudative neovascular age-related macular degeneration (nvAMD) and diabetic macular oedema (DMO). However, false alarms may pose a significant burden to both patients and healthcare professionals alike. PURPOSE: To assess the false alarm rate and positive predictive value of smartphone-based home monitoring of nvAMD and DMO. METHODS: Patients treated with anti-angiogenic therapy in a pro re nata scheme for nvAMD or DMO at the Medical Retina service (Lucerne, Switzerland) between March and June 2016 were included in this prospective cohort study. The home monitoring test Alleye (Oculocare Ltd, Switzerland) provided a session score from 0–100 in addition to a traffic-light system feedback via the smartphone application. Three consecutive “red” scores were considered as a positive test or alarm signal. Specificity, 1-specificity (false alarm rate) and the predictive value for optical coherence tomography-based disease progression were analysed. RESULTS: 73 eyes of 56 patients performed 2258 tests in 222 “follow-up periods”. Progression was observed in 141 periods (63.5%). The specificity of the test was 93.8% (95% CI: 86.2–98.0%), the false alarm rate 6.1% (95% CI: 2.0–13.8%), and the positive predictive value 80.0% (95% CI: 59.3–93.2%) for the detection of progression. CONCLUSION: False alarm rates for the detection of progression in macular disease via home monitoring is low. These findings suggest that home monitoring may be a useful adjunct for remote management of nvAMD and DMO. Nature Publishing Group UK 2021-01-07 2021-11 /pmc/articles/PMC7790308/ /pubmed/33414531 http://dx.doi.org/10.1038/s41433-020-01356-2 Text en © The Royal College of Ophthalmologists 2021, corrected publication 2021
spellingShingle Article
Faes, Livia
Islam, Meriam
Bachmann, Lucas M.
Lienhard, Kenny R.
Schmid, Martin K.
Sim, Dawn A.
False alarms and the positive predictive value of smartphone-based hyperacuity home monitoring for the progression of macular disease: a prospective cohort study
title False alarms and the positive predictive value of smartphone-based hyperacuity home monitoring for the progression of macular disease: a prospective cohort study
title_full False alarms and the positive predictive value of smartphone-based hyperacuity home monitoring for the progression of macular disease: a prospective cohort study
title_fullStr False alarms and the positive predictive value of smartphone-based hyperacuity home monitoring for the progression of macular disease: a prospective cohort study
title_full_unstemmed False alarms and the positive predictive value of smartphone-based hyperacuity home monitoring for the progression of macular disease: a prospective cohort study
title_short False alarms and the positive predictive value of smartphone-based hyperacuity home monitoring for the progression of macular disease: a prospective cohort study
title_sort false alarms and the positive predictive value of smartphone-based hyperacuity home monitoring for the progression of macular disease: a prospective cohort study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7790308/
https://www.ncbi.nlm.nih.gov/pubmed/33414531
http://dx.doi.org/10.1038/s41433-020-01356-2
work_keys_str_mv AT faeslivia falsealarmsandthepositivepredictivevalueofsmartphonebasedhyperacuityhomemonitoringfortheprogressionofmaculardiseaseaprospectivecohortstudy
AT islammeriam falsealarmsandthepositivepredictivevalueofsmartphonebasedhyperacuityhomemonitoringfortheprogressionofmaculardiseaseaprospectivecohortstudy
AT bachmannlucasm falsealarmsandthepositivepredictivevalueofsmartphonebasedhyperacuityhomemonitoringfortheprogressionofmaculardiseaseaprospectivecohortstudy
AT lienhardkennyr falsealarmsandthepositivepredictivevalueofsmartphonebasedhyperacuityhomemonitoringfortheprogressionofmaculardiseaseaprospectivecohortstudy
AT schmidmartink falsealarmsandthepositivepredictivevalueofsmartphonebasedhyperacuityhomemonitoringfortheprogressionofmaculardiseaseaprospectivecohortstudy
AT simdawna falsealarmsandthepositivepredictivevalueofsmartphonebasedhyperacuityhomemonitoringfortheprogressionofmaculardiseaseaprospectivecohortstudy