Cargando…

Effect of the volumetric dimensions of a complete arch on the accuracy of scanners

PURPOSE: The present study aimed to evaluate the accuracy of a desktop scanner and intraoral scanners based on the volumetric dimensions of a complete arch. MATERIALS AND METHODS: Seven reference models were fabricated based on the volumetric dimensions of complete arch (70%, 80%, 90%, 100%, 110%, 1...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Min-Kyu, Son, KeunBaDa, Yu, Beom-Young, Lee, Kyu-Bok
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7790599/
https://www.ncbi.nlm.nih.gov/pubmed/33489020
http://dx.doi.org/10.4047/jap.2020.12.6.361
_version_ 1783633460090372096
author Kim, Min-Kyu
Son, KeunBaDa
Yu, Beom-Young
Lee, Kyu-Bok
author_facet Kim, Min-Kyu
Son, KeunBaDa
Yu, Beom-Young
Lee, Kyu-Bok
author_sort Kim, Min-Kyu
collection PubMed
description PURPOSE: The present study aimed to evaluate the accuracy of a desktop scanner and intraoral scanners based on the volumetric dimensions of a complete arch. MATERIALS AND METHODS: Seven reference models were fabricated based on the volumetric dimensions of complete arch (70%, 80%, 90%, 100%, 110%, 120%, and 130%). The reference models were digitized using an industrial scanner (Solutionix C500; MEDIT) for the fabrication of a computer-aided design (CAD) reference model (CRM). The reference models were digitized using three intraoral scanners (CS3600, Trios3, and i500) and one desktop scanner (E1) to fabricate a CAD test model (CTM). CRM and CTM were then superimposed using inspection software, and 3D analysis was conducted. For statistical analysis, one-way analysis of variance was used to verify the difference in accuracy based on the volumetric dimensions of the complete arch and the accuracy based on the scanners, and the differences among the groups were analyzed using the Tukey HSD test as a post-hoc test (α=.05). RESULTS: The three different scanners showed a significant difference in accuracy based on the volumetric dimensions of the complete arch (P<.05), but the desktop scanner did not show a significant difference in accuracy based on the volumetric dimensions of the complete arch (P=.808). CONCLUSION: The accuracy of the intraoral scanners was dependent on the volumetric dimensions of the complete arch, but the volumetric dimensions of the complete arch had no effect on the accuracy of the desktop scanner. Additionally, depending on the type of intraoral scanners, the accuracy differed according to the volumetric dimensions of the complete arch.
format Online
Article
Text
id pubmed-7790599
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-77905992021-01-21 Effect of the volumetric dimensions of a complete arch on the accuracy of scanners Kim, Min-Kyu Son, KeunBaDa Yu, Beom-Young Lee, Kyu-Bok J Adv Prosthodont Original Article PURPOSE: The present study aimed to evaluate the accuracy of a desktop scanner and intraoral scanners based on the volumetric dimensions of a complete arch. MATERIALS AND METHODS: Seven reference models were fabricated based on the volumetric dimensions of complete arch (70%, 80%, 90%, 100%, 110%, 120%, and 130%). The reference models were digitized using an industrial scanner (Solutionix C500; MEDIT) for the fabrication of a computer-aided design (CAD) reference model (CRM). The reference models were digitized using three intraoral scanners (CS3600, Trios3, and i500) and one desktop scanner (E1) to fabricate a CAD test model (CTM). CRM and CTM were then superimposed using inspection software, and 3D analysis was conducted. For statistical analysis, one-way analysis of variance was used to verify the difference in accuracy based on the volumetric dimensions of the complete arch and the accuracy based on the scanners, and the differences among the groups were analyzed using the Tukey HSD test as a post-hoc test (α=.05). RESULTS: The three different scanners showed a significant difference in accuracy based on the volumetric dimensions of the complete arch (P<.05), but the desktop scanner did not show a significant difference in accuracy based on the volumetric dimensions of the complete arch (P=.808). CONCLUSION: The accuracy of the intraoral scanners was dependent on the volumetric dimensions of the complete arch, but the volumetric dimensions of the complete arch had no effect on the accuracy of the desktop scanner. Additionally, depending on the type of intraoral scanners, the accuracy differed according to the volumetric dimensions of the complete arch. The Korean Academy of Prosthodontics 2020-12 2020-12-28 /pmc/articles/PMC7790599/ /pubmed/33489020 http://dx.doi.org/10.4047/jap.2020.12.6.361 Text en © 2020 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kim, Min-Kyu
Son, KeunBaDa
Yu, Beom-Young
Lee, Kyu-Bok
Effect of the volumetric dimensions of a complete arch on the accuracy of scanners
title Effect of the volumetric dimensions of a complete arch on the accuracy of scanners
title_full Effect of the volumetric dimensions of a complete arch on the accuracy of scanners
title_fullStr Effect of the volumetric dimensions of a complete arch on the accuracy of scanners
title_full_unstemmed Effect of the volumetric dimensions of a complete arch on the accuracy of scanners
title_short Effect of the volumetric dimensions of a complete arch on the accuracy of scanners
title_sort effect of the volumetric dimensions of a complete arch on the accuracy of scanners
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7790599/
https://www.ncbi.nlm.nih.gov/pubmed/33489020
http://dx.doi.org/10.4047/jap.2020.12.6.361
work_keys_str_mv AT kimminkyu effectofthevolumetricdimensionsofacompletearchontheaccuracyofscanners
AT sonkeunbada effectofthevolumetricdimensionsofacompletearchontheaccuracyofscanners
AT yubeomyoung effectofthevolumetricdimensionsofacompletearchontheaccuracyofscanners
AT leekyubok effectofthevolumetricdimensionsofacompletearchontheaccuracyofscanners