Cargando…
High‐Sensitivity Cardiac Troponin I and T Response Following Strenuous Activity is Attenuated by Smokeless Tobacco: NEEDED (North Sea Race Endurance Exercise Study) 2014
BACKGROUND: Use of snus, a smokeless tobacco product, is increasing in Scandinavia. Strenuous physical activity is associated with an acute increase in high‐sensitivity cardiac troponin (swhs‐cTn) concentrations. Current smoking is associated with lower hs‐cTn, but whether this also holds true for s...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7792397/ https://www.ncbi.nlm.nih.gov/pubmed/32930023 http://dx.doi.org/10.1161/JAHA.120.017363 |
_version_ | 1783633796575264768 |
---|---|
author | Skranes, Julia Brox Kleiven, Øyunn Aakre, Kristin Moberg Skadberg, Øyvind Melberg, Tor H. Omland, Torbjørn Ørn, Stein |
author_facet | Skranes, Julia Brox Kleiven, Øyunn Aakre, Kristin Moberg Skadberg, Øyvind Melberg, Tor H. Omland, Torbjørn Ørn, Stein |
author_sort | Skranes, Julia Brox |
collection | PubMed |
description | BACKGROUND: Use of snus, a smokeless tobacco product, is increasing in Scandinavia. Strenuous physical activity is associated with an acute increase in high‐sensitivity cardiac troponin (swhs‐cTn) concentrations. Current smoking is associated with lower hs‐cTn, but whether this also holds true for smokeless tobacco and whether tobacco affects the hs‐cTn response to exercise remain unknown. METHODS AND RESULTS: We measured hs‐cTnI and hs‐cTnT concentrations in 914 recreational athletes before and 3 and 24 hours after a 91‐km bicycle race. Self‐reported snus tobacco habits were reported as noncurrent (n=796) and current (n=118). The association between snus use and change in log‐transformed hs‐cTnI and hs‐cTnT concentrations (ie, the differences between concentrations at baseline and 3 hours and 24 hours ) were assessed by multivariable linear regression analysis. Concentrations of hs‐cTn at baseline were lower in current than in noncurrent snus users (hs‐cTnI median, 1.7 ng/L; Q1 to Q3: 1.6–2.3 versus 2.0 ng/L; Q1 to Q3: 1.6–3.2 [P=0.020]; and hs‐cTnT: median, 2.9 ng/L, Q1 to Q3: 2.9–3.5 versus 2.9 ng/L, Q1 to Q3: 2.9–4.3 [P=0.021]). In fully adjusted multivariable models, use of snus was associated with lower change in hs‐cTn concentrations from baseline to 3 hours (hs‐cTnI: −29% [P=0.002], hs‐cTnT: −18% [P=0.010]) and 24 hours (hscTnI: −30% [P=0.010], hs‐cTnT −19%, [P=0.013]). CONCLUSIONS: Resting hs‐cTn concentrations are lower and the exercise‐induced cardiac troponin response is attenuated in current users of smokeless tobacco compared with nonusers. Further insight into the pathophysiological processes underlying the attenuated cardiac troponin response to exercise in tobacco users is needed. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02166216. |
format | Online Article Text |
id | pubmed-7792397 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-77923972021-01-15 High‐Sensitivity Cardiac Troponin I and T Response Following Strenuous Activity is Attenuated by Smokeless Tobacco: NEEDED (North Sea Race Endurance Exercise Study) 2014 Skranes, Julia Brox Kleiven, Øyunn Aakre, Kristin Moberg Skadberg, Øyvind Melberg, Tor H. Omland, Torbjørn Ørn, Stein J Am Heart Assoc Original Research BACKGROUND: Use of snus, a smokeless tobacco product, is increasing in Scandinavia. Strenuous physical activity is associated with an acute increase in high‐sensitivity cardiac troponin (swhs‐cTn) concentrations. Current smoking is associated with lower hs‐cTn, but whether this also holds true for smokeless tobacco and whether tobacco affects the hs‐cTn response to exercise remain unknown. METHODS AND RESULTS: We measured hs‐cTnI and hs‐cTnT concentrations in 914 recreational athletes before and 3 and 24 hours after a 91‐km bicycle race. Self‐reported snus tobacco habits were reported as noncurrent (n=796) and current (n=118). The association between snus use and change in log‐transformed hs‐cTnI and hs‐cTnT concentrations (ie, the differences between concentrations at baseline and 3 hours and 24 hours ) were assessed by multivariable linear regression analysis. Concentrations of hs‐cTn at baseline were lower in current than in noncurrent snus users (hs‐cTnI median, 1.7 ng/L; Q1 to Q3: 1.6–2.3 versus 2.0 ng/L; Q1 to Q3: 1.6–3.2 [P=0.020]; and hs‐cTnT: median, 2.9 ng/L, Q1 to Q3: 2.9–3.5 versus 2.9 ng/L, Q1 to Q3: 2.9–4.3 [P=0.021]). In fully adjusted multivariable models, use of snus was associated with lower change in hs‐cTn concentrations from baseline to 3 hours (hs‐cTnI: −29% [P=0.002], hs‐cTnT: −18% [P=0.010]) and 24 hours (hscTnI: −30% [P=0.010], hs‐cTnT −19%, [P=0.013]). CONCLUSIONS: Resting hs‐cTn concentrations are lower and the exercise‐induced cardiac troponin response is attenuated in current users of smokeless tobacco compared with nonusers. Further insight into the pathophysiological processes underlying the attenuated cardiac troponin response to exercise in tobacco users is needed. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02166216. John Wiley and Sons Inc. 2020-09-15 /pmc/articles/PMC7792397/ /pubmed/32930023 http://dx.doi.org/10.1161/JAHA.120.017363 Text en © 2020 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley. This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Original Research Skranes, Julia Brox Kleiven, Øyunn Aakre, Kristin Moberg Skadberg, Øyvind Melberg, Tor H. Omland, Torbjørn Ørn, Stein High‐Sensitivity Cardiac Troponin I and T Response Following Strenuous Activity is Attenuated by Smokeless Tobacco: NEEDED (North Sea Race Endurance Exercise Study) 2014 |
title | High‐Sensitivity Cardiac Troponin I and T Response Following Strenuous Activity is Attenuated by Smokeless Tobacco: NEEDED (North Sea Race Endurance Exercise Study) 2014 |
title_full | High‐Sensitivity Cardiac Troponin I and T Response Following Strenuous Activity is Attenuated by Smokeless Tobacco: NEEDED (North Sea Race Endurance Exercise Study) 2014 |
title_fullStr | High‐Sensitivity Cardiac Troponin I and T Response Following Strenuous Activity is Attenuated by Smokeless Tobacco: NEEDED (North Sea Race Endurance Exercise Study) 2014 |
title_full_unstemmed | High‐Sensitivity Cardiac Troponin I and T Response Following Strenuous Activity is Attenuated by Smokeless Tobacco: NEEDED (North Sea Race Endurance Exercise Study) 2014 |
title_short | High‐Sensitivity Cardiac Troponin I and T Response Following Strenuous Activity is Attenuated by Smokeless Tobacco: NEEDED (North Sea Race Endurance Exercise Study) 2014 |
title_sort | high‐sensitivity cardiac troponin i and t response following strenuous activity is attenuated by smokeless tobacco: needed (north sea race endurance exercise study) 2014 |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7792397/ https://www.ncbi.nlm.nih.gov/pubmed/32930023 http://dx.doi.org/10.1161/JAHA.120.017363 |
work_keys_str_mv | AT skranesjuliabrox highsensitivitycardiactroponiniandtresponsefollowingstrenuousactivityisattenuatedbysmokelesstobacconeedednorthsearaceenduranceexercisestudy2014 AT kleivenøyunn highsensitivitycardiactroponiniandtresponsefollowingstrenuousactivityisattenuatedbysmokelesstobacconeedednorthsearaceenduranceexercisestudy2014 AT aakrekristinmoberg highsensitivitycardiactroponiniandtresponsefollowingstrenuousactivityisattenuatedbysmokelesstobacconeedednorthsearaceenduranceexercisestudy2014 AT skadbergøyvind highsensitivitycardiactroponiniandtresponsefollowingstrenuousactivityisattenuatedbysmokelesstobacconeedednorthsearaceenduranceexercisestudy2014 AT melbergtorh highsensitivitycardiactroponiniandtresponsefollowingstrenuousactivityisattenuatedbysmokelesstobacconeedednorthsearaceenduranceexercisestudy2014 AT omlandtorbjørn highsensitivitycardiactroponiniandtresponsefollowingstrenuousactivityisattenuatedbysmokelesstobacconeedednorthsearaceenduranceexercisestudy2014 AT ørnstein highsensitivitycardiactroponiniandtresponsefollowingstrenuousactivityisattenuatedbysmokelesstobacconeedednorthsearaceenduranceexercisestudy2014 |