Cargando…
The reliability and validity of the weight-bearing lunge test in a Congenital Talipes Equinovarus population (CTEV)
QUESTION: What is the intra and inter-rater reliability and concurrent validity of the weight-bearing lunge test within a Congenital Talipes Equinovarus population? DESIGN: Test retest design for reliability and validity. The measure was taken, following preconditioning of the participants, using di...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
PeerJ Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7792513/ https://www.ncbi.nlm.nih.gov/pubmed/33505779 http://dx.doi.org/10.7717/peerj.10253 |
_version_ | 1783633822112284672 |
---|---|
author | Gosse, Georgia Ward, Emily McIntyre, Auburn Banwell, Helen A. |
author_facet | Gosse, Georgia Ward, Emily McIntyre, Auburn Banwell, Helen A. |
author_sort | Gosse, Georgia |
collection | PubMed |
description | QUESTION: What is the intra and inter-rater reliability and concurrent validity of the weight-bearing lunge test within a Congenital Talipes Equinovarus population? DESIGN: Test retest design for reliability and validity. The measure was taken, following preconditioning of the participants, using distance from wall, angle at distal posterior tibia using a digital inclinometer and the iPhone level function, twice by each rater. The raters included a clinician, clinician in training and a parent/carer. OUTCOME MEASURES: Weight bearing lunge test as a measure of ankle dorsiflexion. RESULTS: Twelve children aged 5–10 years were eligible to participate and consented, along with their parents. Intra-reliability of distance measures for all raters were good to excellent (ICC clinician 0.95, ICC training clinician 0.98 and ICC parent 0.89). Intra-rater reliability of the iPhone for all raters was good (ICCs > 0.751) and good to excellent for the inclinometer (ICC clinician 0.87, ICC training clinician 0.90). Concurrent validity between the clinician’s and parents distance measure was also high with ICC of 0.899. Inter-rater reliability was excellent for distance measure (ICC = 0.948), good for the inclinometer (ICC = 0.801) and moderate for the iPhone (ICC = 0.68). Standard error of measurement ranged from 0.70–2.05, whilst the minimal detectable change ranged from 1.90–5.70. CONCLUSION: The use of the WBLT within this CTEV population has demonstrated good to excellent reliability and validity amongst clinicians, clinicians in training and parents/carers, supporting its use as an assessment measure of dorsiflexion range of motion. There is support for parents/carers to use the WBLT at home as a monitoring assessment measure which may assist with early detection of a relapse. TRIAL REGISTRATION: University of South Australia’s ethics committee (ID: 201397); Women’s and Children’s Hospital ethics committee (AU/1/4BD7310). |
format | Online Article Text |
id | pubmed-7792513 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | PeerJ Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-77925132021-01-26 The reliability and validity of the weight-bearing lunge test in a Congenital Talipes Equinovarus population (CTEV) Gosse, Georgia Ward, Emily McIntyre, Auburn Banwell, Helen A. PeerJ Kinesiology QUESTION: What is the intra and inter-rater reliability and concurrent validity of the weight-bearing lunge test within a Congenital Talipes Equinovarus population? DESIGN: Test retest design for reliability and validity. The measure was taken, following preconditioning of the participants, using distance from wall, angle at distal posterior tibia using a digital inclinometer and the iPhone level function, twice by each rater. The raters included a clinician, clinician in training and a parent/carer. OUTCOME MEASURES: Weight bearing lunge test as a measure of ankle dorsiflexion. RESULTS: Twelve children aged 5–10 years were eligible to participate and consented, along with their parents. Intra-reliability of distance measures for all raters were good to excellent (ICC clinician 0.95, ICC training clinician 0.98 and ICC parent 0.89). Intra-rater reliability of the iPhone for all raters was good (ICCs > 0.751) and good to excellent for the inclinometer (ICC clinician 0.87, ICC training clinician 0.90). Concurrent validity between the clinician’s and parents distance measure was also high with ICC of 0.899. Inter-rater reliability was excellent for distance measure (ICC = 0.948), good for the inclinometer (ICC = 0.801) and moderate for the iPhone (ICC = 0.68). Standard error of measurement ranged from 0.70–2.05, whilst the minimal detectable change ranged from 1.90–5.70. CONCLUSION: The use of the WBLT within this CTEV population has demonstrated good to excellent reliability and validity amongst clinicians, clinicians in training and parents/carers, supporting its use as an assessment measure of dorsiflexion range of motion. There is support for parents/carers to use the WBLT at home as a monitoring assessment measure which may assist with early detection of a relapse. TRIAL REGISTRATION: University of South Australia’s ethics committee (ID: 201397); Women’s and Children’s Hospital ethics committee (AU/1/4BD7310). PeerJ Inc. 2021-01-05 /pmc/articles/PMC7792513/ /pubmed/33505779 http://dx.doi.org/10.7717/peerj.10253 Text en ©2021 Gosse et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, reproduction and adaptation in any medium and for any purpose provided that it is properly attributed. For attribution, the original author(s), title, publication source (PeerJ) and either DOI or URL of the article must be cited. |
spellingShingle | Kinesiology Gosse, Georgia Ward, Emily McIntyre, Auburn Banwell, Helen A. The reliability and validity of the weight-bearing lunge test in a Congenital Talipes Equinovarus population (CTEV) |
title | The reliability and validity of the weight-bearing lunge test in a Congenital Talipes Equinovarus population (CTEV) |
title_full | The reliability and validity of the weight-bearing lunge test in a Congenital Talipes Equinovarus population (CTEV) |
title_fullStr | The reliability and validity of the weight-bearing lunge test in a Congenital Talipes Equinovarus population (CTEV) |
title_full_unstemmed | The reliability and validity of the weight-bearing lunge test in a Congenital Talipes Equinovarus population (CTEV) |
title_short | The reliability and validity of the weight-bearing lunge test in a Congenital Talipes Equinovarus population (CTEV) |
title_sort | reliability and validity of the weight-bearing lunge test in a congenital talipes equinovarus population (ctev) |
topic | Kinesiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7792513/ https://www.ncbi.nlm.nih.gov/pubmed/33505779 http://dx.doi.org/10.7717/peerj.10253 |
work_keys_str_mv | AT gossegeorgia thereliabilityandvalidityoftheweightbearinglungetestinacongenitaltalipesequinovaruspopulationctev AT wardemily thereliabilityandvalidityoftheweightbearinglungetestinacongenitaltalipesequinovaruspopulationctev AT mcintyreauburn thereliabilityandvalidityoftheweightbearinglungetestinacongenitaltalipesequinovaruspopulationctev AT banwellhelena thereliabilityandvalidityoftheweightbearinglungetestinacongenitaltalipesequinovaruspopulationctev AT gossegeorgia reliabilityandvalidityoftheweightbearinglungetestinacongenitaltalipesequinovaruspopulationctev AT wardemily reliabilityandvalidityoftheweightbearinglungetestinacongenitaltalipesequinovaruspopulationctev AT mcintyreauburn reliabilityandvalidityoftheweightbearinglungetestinacongenitaltalipesequinovaruspopulationctev AT banwellhelena reliabilityandvalidityoftheweightbearinglungetestinacongenitaltalipesequinovaruspopulationctev |