Cargando…

Continuous Maternal Hemodynamics Monitoring at Delivery Using a Novel, Noninvasive, Wireless, PPG-Based Sensor

Objective: To evaluate continuous monitoring of maternal hemodynamics during labor and delivery utilizing an innovative, noninvasive, reflective photoplethysmography-based device. Study design: The Biobeat Monitoring Platform includes a wearable wristwatch monitor that automatically samples cardiac...

Descripción completa

Detalles Bibliográficos
Autores principales: Atzmon, Yuval, Ben Ishay, Efrat, Hallak, Mordechai, Littman, Romi, Eisenkraft, Arik, Gabbay-Benziv, Rinat
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7793094/
https://www.ncbi.nlm.nih.gov/pubmed/33375211
http://dx.doi.org/10.3390/jcm10010008
_version_ 1783633914407944192
author Atzmon, Yuval
Ben Ishay, Efrat
Hallak, Mordechai
Littman, Romi
Eisenkraft, Arik
Gabbay-Benziv, Rinat
author_facet Atzmon, Yuval
Ben Ishay, Efrat
Hallak, Mordechai
Littman, Romi
Eisenkraft, Arik
Gabbay-Benziv, Rinat
author_sort Atzmon, Yuval
collection PubMed
description Objective: To evaluate continuous monitoring of maternal hemodynamics during labor and delivery utilizing an innovative, noninvasive, reflective photoplethysmography-based device. Study design: The Biobeat Monitoring Platform includes a wearable wristwatch monitor that automatically samples cardiac output (CO), blood pressure (BP), stroke volume (SV), systemic vascular resistance (SVR), heart rate (HR) every 5 s and uploads all data to a smartphone-based app and to a data cloud, enabling remote patient monitoring and analysis of data. Low-risk parturients at term, carrying singletons pregnancies, were recruited at early delivery prior to the active phase. Big data analysis of the collected data was performed using the Power BI analysis tool (Microsoft). Next, data were normalized to visual presentation using Excel Data Analysis and the regression tool. Average measurements were compared before and after rupture of membranes, epidural anesthesia, fetal delivery, and placental expulsion. Results: Eighty-one parturients entered analysis. Epidural anesthesia was associated with a slight elevation in CO (5.5 vs. 5.6, L/min, 10 min before and after EA, p < 0.05) attributed to a non-significant increase in both HR and SV. BP remained stable as of counter decrease in SVR (1361 vs. 1319 mmHg⋅min⋅mL(−1), 10 min before and after EA, p < 0.05). Fetal delivery was associated with a peak in CO after which it rapidly declined (6.0 vs. 7.2 vs. 6.1 L/min, 30 min before vs. point of delivery vs. after delivery, p < 0.05). The mean BP remained stable throughout delivery with a slight increase at fetal delivery (92 vs. 95 vs. 92.1 mmHg, p < 0.05), reflecting the increase in CO and decrease in SVR (1284 vs. 1112 vs. 1280 mmHg⋅min⋅mL(−1), p < 0.05)with delivery. Placental expulsion was associated with a second peak in CO and decrease in SVR. Conclusions: We presented a novel application of noninvasive hemodynamic maternal monitoring throughout labor and delivery for both research and clinical use.
format Online
Article
Text
id pubmed-7793094
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-77930942021-01-09 Continuous Maternal Hemodynamics Monitoring at Delivery Using a Novel, Noninvasive, Wireless, PPG-Based Sensor Atzmon, Yuval Ben Ishay, Efrat Hallak, Mordechai Littman, Romi Eisenkraft, Arik Gabbay-Benziv, Rinat J Clin Med Article Objective: To evaluate continuous monitoring of maternal hemodynamics during labor and delivery utilizing an innovative, noninvasive, reflective photoplethysmography-based device. Study design: The Biobeat Monitoring Platform includes a wearable wristwatch monitor that automatically samples cardiac output (CO), blood pressure (BP), stroke volume (SV), systemic vascular resistance (SVR), heart rate (HR) every 5 s and uploads all data to a smartphone-based app and to a data cloud, enabling remote patient monitoring and analysis of data. Low-risk parturients at term, carrying singletons pregnancies, were recruited at early delivery prior to the active phase. Big data analysis of the collected data was performed using the Power BI analysis tool (Microsoft). Next, data were normalized to visual presentation using Excel Data Analysis and the regression tool. Average measurements were compared before and after rupture of membranes, epidural anesthesia, fetal delivery, and placental expulsion. Results: Eighty-one parturients entered analysis. Epidural anesthesia was associated with a slight elevation in CO (5.5 vs. 5.6, L/min, 10 min before and after EA, p < 0.05) attributed to a non-significant increase in both HR and SV. BP remained stable as of counter decrease in SVR (1361 vs. 1319 mmHg⋅min⋅mL(−1), 10 min before and after EA, p < 0.05). Fetal delivery was associated with a peak in CO after which it rapidly declined (6.0 vs. 7.2 vs. 6.1 L/min, 30 min before vs. point of delivery vs. after delivery, p < 0.05). The mean BP remained stable throughout delivery with a slight increase at fetal delivery (92 vs. 95 vs. 92.1 mmHg, p < 0.05), reflecting the increase in CO and decrease in SVR (1284 vs. 1112 vs. 1280 mmHg⋅min⋅mL(−1), p < 0.05)with delivery. Placental expulsion was associated with a second peak in CO and decrease in SVR. Conclusions: We presented a novel application of noninvasive hemodynamic maternal monitoring throughout labor and delivery for both research and clinical use. MDPI 2020-12-22 /pmc/articles/PMC7793094/ /pubmed/33375211 http://dx.doi.org/10.3390/jcm10010008 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Atzmon, Yuval
Ben Ishay, Efrat
Hallak, Mordechai
Littman, Romi
Eisenkraft, Arik
Gabbay-Benziv, Rinat
Continuous Maternal Hemodynamics Monitoring at Delivery Using a Novel, Noninvasive, Wireless, PPG-Based Sensor
title Continuous Maternal Hemodynamics Monitoring at Delivery Using a Novel, Noninvasive, Wireless, PPG-Based Sensor
title_full Continuous Maternal Hemodynamics Monitoring at Delivery Using a Novel, Noninvasive, Wireless, PPG-Based Sensor
title_fullStr Continuous Maternal Hemodynamics Monitoring at Delivery Using a Novel, Noninvasive, Wireless, PPG-Based Sensor
title_full_unstemmed Continuous Maternal Hemodynamics Monitoring at Delivery Using a Novel, Noninvasive, Wireless, PPG-Based Sensor
title_short Continuous Maternal Hemodynamics Monitoring at Delivery Using a Novel, Noninvasive, Wireless, PPG-Based Sensor
title_sort continuous maternal hemodynamics monitoring at delivery using a novel, noninvasive, wireless, ppg-based sensor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7793094/
https://www.ncbi.nlm.nih.gov/pubmed/33375211
http://dx.doi.org/10.3390/jcm10010008
work_keys_str_mv AT atzmonyuval continuousmaternalhemodynamicsmonitoringatdeliveryusinganovelnoninvasivewirelessppgbasedsensor
AT benishayefrat continuousmaternalhemodynamicsmonitoringatdeliveryusinganovelnoninvasivewirelessppgbasedsensor
AT hallakmordechai continuousmaternalhemodynamicsmonitoringatdeliveryusinganovelnoninvasivewirelessppgbasedsensor
AT littmanromi continuousmaternalhemodynamicsmonitoringatdeliveryusinganovelnoninvasivewirelessppgbasedsensor
AT eisenkraftarik continuousmaternalhemodynamicsmonitoringatdeliveryusinganovelnoninvasivewirelessppgbasedsensor
AT gabbaybenzivrinat continuousmaternalhemodynamicsmonitoringatdeliveryusinganovelnoninvasivewirelessppgbasedsensor