Cargando…

Valve-in-valve transcatheter aortic valve implantation with fracturing of a failed small surgical aortic bioprosthesis: a case report

BACKGROUND: Failure of a small surgical aortic bioprosthesis represents a challenging clinical scenario with valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) often resulting in patient-prosthesis mismatch. Bioprosthetic valve fracture (BVF) performed as a part of the ViV TAVI has...

Descripción completa

Detalles Bibliográficos
Autores principales: Bunc, Matjaz, Cercek, Miha, Podlesnikar, Tomaz, Terseglav, Simon, Steblovnik, Klemen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7793178/
https://www.ncbi.nlm.nih.gov/pubmed/33442638
http://dx.doi.org/10.1093/ehjcr/ytaa356
_version_ 1783633932203327488
author Bunc, Matjaz
Cercek, Miha
Podlesnikar, Tomaz
Terseglav, Simon
Steblovnik, Klemen
author_facet Bunc, Matjaz
Cercek, Miha
Podlesnikar, Tomaz
Terseglav, Simon
Steblovnik, Klemen
author_sort Bunc, Matjaz
collection PubMed
description BACKGROUND: Failure of a small surgical aortic bioprosthesis represents a challenging clinical scenario with valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) often resulting in patient-prosthesis mismatch. Bioprosthetic valve fracture (BVF) performed as a part of the ViV TAVI has recently emerged as an alternative approach with certain types of surgical bioprostheses. CASE SUMMARY: An 81-year-old woman with a history of three surgical aortic valve procedures presented with heart failure. Aortic bioprosthesis degeneration with severe stenosis and moderate regurgitation was found. The patient was deemed a high-risk surgical candidate and the heart team decided that ViV TAVI was the preferred treatment option. Due to the very small 19 mm stented surgical aortic bioprosthesis Mitroflow 19 mm (Sorin Group, Italy) we decided to perform BVF as a part of ViV TAVI to prevent patient-prosthesis mismatch. Since this was the first BVF procedure in our centre, an ex vivo BVF of the same kind of bioprosthetic valve was performed first. Subsequently, successful BVF with implantation of Evolut R 23 mm (Medtronic, USA) self-expandable transcatheter valve was performed. Excellent haemodynamic result was achieved and no periprocedural complications were present. The patient had an immediate major improvement in clinical status and remains asymptomatic after 6 months. DISCUSSION: Bioprosthetic valve fracture together with ViV TAVI is a safe and effective emerging technique for treatment of small surgical aortic bioprosthesis failure. Bioprosthetic valve fracture allows marked oversizing of implanted self-expandable transcatheter aortic valves, leading to excellent haemodynamic and clinical results. An ex vivo BVF can serve as an important preparatory step when introducing the new method.
format Online
Article
Text
id pubmed-7793178
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-77931782021-01-12 Valve-in-valve transcatheter aortic valve implantation with fracturing of a failed small surgical aortic bioprosthesis: a case report Bunc, Matjaz Cercek, Miha Podlesnikar, Tomaz Terseglav, Simon Steblovnik, Klemen Eur Heart J Case Rep Case Reports BACKGROUND: Failure of a small surgical aortic bioprosthesis represents a challenging clinical scenario with valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) often resulting in patient-prosthesis mismatch. Bioprosthetic valve fracture (BVF) performed as a part of the ViV TAVI has recently emerged as an alternative approach with certain types of surgical bioprostheses. CASE SUMMARY: An 81-year-old woman with a history of three surgical aortic valve procedures presented with heart failure. Aortic bioprosthesis degeneration with severe stenosis and moderate regurgitation was found. The patient was deemed a high-risk surgical candidate and the heart team decided that ViV TAVI was the preferred treatment option. Due to the very small 19 mm stented surgical aortic bioprosthesis Mitroflow 19 mm (Sorin Group, Italy) we decided to perform BVF as a part of ViV TAVI to prevent patient-prosthesis mismatch. Since this was the first BVF procedure in our centre, an ex vivo BVF of the same kind of bioprosthetic valve was performed first. Subsequently, successful BVF with implantation of Evolut R 23 mm (Medtronic, USA) self-expandable transcatheter valve was performed. Excellent haemodynamic result was achieved and no periprocedural complications were present. The patient had an immediate major improvement in clinical status and remains asymptomatic after 6 months. DISCUSSION: Bioprosthetic valve fracture together with ViV TAVI is a safe and effective emerging technique for treatment of small surgical aortic bioprosthesis failure. Bioprosthetic valve fracture allows marked oversizing of implanted self-expandable transcatheter aortic valves, leading to excellent haemodynamic and clinical results. An ex vivo BVF can serve as an important preparatory step when introducing the new method. Oxford University Press 2020-11-19 /pmc/articles/PMC7793178/ /pubmed/33442638 http://dx.doi.org/10.1093/ehjcr/ytaa356 Text en © The Author(s) 2020. Published by Oxford University Press on behalf of the European Society of Cardiology. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Case Reports
Bunc, Matjaz
Cercek, Miha
Podlesnikar, Tomaz
Terseglav, Simon
Steblovnik, Klemen
Valve-in-valve transcatheter aortic valve implantation with fracturing of a failed small surgical aortic bioprosthesis: a case report
title Valve-in-valve transcatheter aortic valve implantation with fracturing of a failed small surgical aortic bioprosthesis: a case report
title_full Valve-in-valve transcatheter aortic valve implantation with fracturing of a failed small surgical aortic bioprosthesis: a case report
title_fullStr Valve-in-valve transcatheter aortic valve implantation with fracturing of a failed small surgical aortic bioprosthesis: a case report
title_full_unstemmed Valve-in-valve transcatheter aortic valve implantation with fracturing of a failed small surgical aortic bioprosthesis: a case report
title_short Valve-in-valve transcatheter aortic valve implantation with fracturing of a failed small surgical aortic bioprosthesis: a case report
title_sort valve-in-valve transcatheter aortic valve implantation with fracturing of a failed small surgical aortic bioprosthesis: a case report
topic Case Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7793178/
https://www.ncbi.nlm.nih.gov/pubmed/33442638
http://dx.doi.org/10.1093/ehjcr/ytaa356
work_keys_str_mv AT buncmatjaz valveinvalvetranscatheteraorticvalveimplantationwithfracturingofafailedsmallsurgicalaorticbioprosthesisacasereport
AT cercekmiha valveinvalvetranscatheteraorticvalveimplantationwithfracturingofafailedsmallsurgicalaorticbioprosthesisacasereport
AT podlesnikartomaz valveinvalvetranscatheteraorticvalveimplantationwithfracturingofafailedsmallsurgicalaorticbioprosthesisacasereport
AT terseglavsimon valveinvalvetranscatheteraorticvalveimplantationwithfracturingofafailedsmallsurgicalaorticbioprosthesisacasereport
AT steblovnikklemen valveinvalvetranscatheteraorticvalveimplantationwithfracturingofafailedsmallsurgicalaorticbioprosthesisacasereport