Cargando…

Applicability of ultrasonography for detection of marginal sinus placenta previa

This study aimed to examine whether marginal sinus placenta previa, defined as when the marginal sinus just reaches the internal cervical os and placental parenchyma might be >2 cm from the internal cervical os, can be diagnosed using ultrasonography (US). We identified the placenta previa cases...

Descripción completa

Detalles Bibliográficos
Autores principales: Ishibashi, Hiroki, Miyamoto, Morikazu, Shinmoto, Hiroshi, Soga, Shigeyoshi, Iwahashi, Hideki, Kakimoto, Soichiro, Matsuura, Hiroko, Sakamoto, Takahiro, Hada, Taira, Suzuki, Rie, Takano, Masashi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7793344/
https://www.ncbi.nlm.nih.gov/pubmed/33429830
http://dx.doi.org/10.1097/MD.0000000000024253
_version_ 1783633969072308224
author Ishibashi, Hiroki
Miyamoto, Morikazu
Shinmoto, Hiroshi
Soga, Shigeyoshi
Iwahashi, Hideki
Kakimoto, Soichiro
Matsuura, Hiroko
Sakamoto, Takahiro
Hada, Taira
Suzuki, Rie
Takano, Masashi
author_facet Ishibashi, Hiroki
Miyamoto, Morikazu
Shinmoto, Hiroshi
Soga, Shigeyoshi
Iwahashi, Hideki
Kakimoto, Soichiro
Matsuura, Hiroko
Sakamoto, Takahiro
Hada, Taira
Suzuki, Rie
Takano, Masashi
author_sort Ishibashi, Hiroki
collection PubMed
description This study aimed to examine whether marginal sinus placenta previa, defined as when the marginal sinus just reaches the internal cervical os and placental parenchyma might be >2 cm from the internal cervical os, can be diagnosed using ultrasonography (US). We identified the placenta previa cases that underwent both US and magnetic resonance imaging (MRI) between April 2010 and December 2018 at our institution. The diagnostic discrepancies for marginal sinus placenta previa between US and MRI were examined retrospectively. Of the 183 cases of placenta previa, 28 (15.3%) cases were diagnosed as marginal sinus placenta previa using MRI. Among them, 18 cases (64.3%) could also be diagnosed using US. The sensitivity and specificity of the diagnosis of marginal sinus placenta previa using US were 64.3% and 92.9%, respectively. A change in US diagnosis occurred in 10 (35.7%) cases, all of which were diagnosed with low-lying placenta previa or marginal placenta previa and did not develop any serious miserable obstetrical outcomes. In conclusion, the diagnostic accuracy of US for detecting marginal sinus placenta previa was not significant. MRI examination may be required to accurately categorize the types of placenta previa.
format Online
Article
Text
id pubmed-7793344
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-77933442021-01-11 Applicability of ultrasonography for detection of marginal sinus placenta previa Ishibashi, Hiroki Miyamoto, Morikazu Shinmoto, Hiroshi Soga, Shigeyoshi Iwahashi, Hideki Kakimoto, Soichiro Matsuura, Hiroko Sakamoto, Takahiro Hada, Taira Suzuki, Rie Takano, Masashi Medicine (Baltimore) 5600 This study aimed to examine whether marginal sinus placenta previa, defined as when the marginal sinus just reaches the internal cervical os and placental parenchyma might be >2 cm from the internal cervical os, can be diagnosed using ultrasonography (US). We identified the placenta previa cases that underwent both US and magnetic resonance imaging (MRI) between April 2010 and December 2018 at our institution. The diagnostic discrepancies for marginal sinus placenta previa between US and MRI were examined retrospectively. Of the 183 cases of placenta previa, 28 (15.3%) cases were diagnosed as marginal sinus placenta previa using MRI. Among them, 18 cases (64.3%) could also be diagnosed using US. The sensitivity and specificity of the diagnosis of marginal sinus placenta previa using US were 64.3% and 92.9%, respectively. A change in US diagnosis occurred in 10 (35.7%) cases, all of which were diagnosed with low-lying placenta previa or marginal placenta previa and did not develop any serious miserable obstetrical outcomes. In conclusion, the diagnostic accuracy of US for detecting marginal sinus placenta previa was not significant. MRI examination may be required to accurately categorize the types of placenta previa. Lippincott Williams & Wilkins 2021-01-08 /pmc/articles/PMC7793344/ /pubmed/33429830 http://dx.doi.org/10.1097/MD.0000000000024253 Text en Copyright © 2021 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by/4.0 This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0
spellingShingle 5600
Ishibashi, Hiroki
Miyamoto, Morikazu
Shinmoto, Hiroshi
Soga, Shigeyoshi
Iwahashi, Hideki
Kakimoto, Soichiro
Matsuura, Hiroko
Sakamoto, Takahiro
Hada, Taira
Suzuki, Rie
Takano, Masashi
Applicability of ultrasonography for detection of marginal sinus placenta previa
title Applicability of ultrasonography for detection of marginal sinus placenta previa
title_full Applicability of ultrasonography for detection of marginal sinus placenta previa
title_fullStr Applicability of ultrasonography for detection of marginal sinus placenta previa
title_full_unstemmed Applicability of ultrasonography for detection of marginal sinus placenta previa
title_short Applicability of ultrasonography for detection of marginal sinus placenta previa
title_sort applicability of ultrasonography for detection of marginal sinus placenta previa
topic 5600
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7793344/
https://www.ncbi.nlm.nih.gov/pubmed/33429830
http://dx.doi.org/10.1097/MD.0000000000024253
work_keys_str_mv AT ishibashihiroki applicabilityofultrasonographyfordetectionofmarginalsinusplacentaprevia
AT miyamotomorikazu applicabilityofultrasonographyfordetectionofmarginalsinusplacentaprevia
AT shinmotohiroshi applicabilityofultrasonographyfordetectionofmarginalsinusplacentaprevia
AT sogashigeyoshi applicabilityofultrasonographyfordetectionofmarginalsinusplacentaprevia
AT iwahashihideki applicabilityofultrasonographyfordetectionofmarginalsinusplacentaprevia
AT kakimotosoichiro applicabilityofultrasonographyfordetectionofmarginalsinusplacentaprevia
AT matsuurahiroko applicabilityofultrasonographyfordetectionofmarginalsinusplacentaprevia
AT sakamototakahiro applicabilityofultrasonographyfordetectionofmarginalsinusplacentaprevia
AT hadataira applicabilityofultrasonographyfordetectionofmarginalsinusplacentaprevia
AT suzukirie applicabilityofultrasonographyfordetectionofmarginalsinusplacentaprevia
AT takanomasashi applicabilityofultrasonographyfordetectionofmarginalsinusplacentaprevia