Cargando…
Crack Identification in Necked Double Shear Lugs by Means of the Electro-Mechanical Impedance Method
This contribution investigates fatigue crack detection, localization and quantification in idealized necked double shear lugs using piezoelectric transducers attached to the lug shaft and analyzed by the electro-mechanical impedance (EMI) method. The considered idealized necked lug sample has a simp...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7795087/ https://www.ncbi.nlm.nih.gov/pubmed/33374853 http://dx.doi.org/10.3390/s21010044 |
_version_ | 1783634361838469120 |
---|---|
author | Winklberger, Markus Kralovec, Christoph Humer, Christoph Heftberger, Peter Schagerl, Martin |
author_facet | Winklberger, Markus Kralovec, Christoph Humer, Christoph Heftberger, Peter Schagerl, Martin |
author_sort | Winklberger, Markus |
collection | PubMed |
description | This contribution investigates fatigue crack detection, localization and quantification in idealized necked double shear lugs using piezoelectric transducers attached to the lug shaft and analyzed by the electro-mechanical impedance (EMI) method. The considered idealized necked lug sample has a simplified geometry and does not includes the typical bearing. Numerical simulations with coupled-field finite element (FE) models are used to study the frequency response behavior of necked lugs. These numerical analyses include both pristine and cracked lug models. Through-cracks are located at 90 [Formula: see text] and 145 [Formula: see text] to the lug axis, which are critical spots for damage initiation. The results of FE simulations with a crack location at 90 [Formula: see text] are validated with experiments using an impedance analyzer and a scanning laser Doppler vibrometer. For both experiments, the lug specimen is excited and measured using a piezoelectric active wafer sensor in a frequency range of 1 kHz to 100 kHz. The dynamic response of both numerical calculations and experimental measurements show good agreement. To identify (i.e., detect, locate, and quantify) cracks in necked lugs a two-step analysis is performed. In the first step, a crack is detected data-based by calculating damage metrics between pristine and damaged state frequency spectra and comparing the resulting values to a pre-defined threshold. In the second step the location and size of the detected crack is identified by evaluation of specific resonance frequency shifts of the necked lug. Both the search for frequencies sensitive to through-cracks that allow a distinction between the two critical locations and the evaluation of the crack size are model-based. This two-step analysis based on the EMI method is demonstrated experimentally at the considered idealized necked lug, and thus, represents a promising way to reliably detect, locate and quantify fatigue cracks at critical locations of real necked double shear lugs. |
format | Online Article Text |
id | pubmed-7795087 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-77950872021-01-10 Crack Identification in Necked Double Shear Lugs by Means of the Electro-Mechanical Impedance Method Winklberger, Markus Kralovec, Christoph Humer, Christoph Heftberger, Peter Schagerl, Martin Sensors (Basel) Article This contribution investigates fatigue crack detection, localization and quantification in idealized necked double shear lugs using piezoelectric transducers attached to the lug shaft and analyzed by the electro-mechanical impedance (EMI) method. The considered idealized necked lug sample has a simplified geometry and does not includes the typical bearing. Numerical simulations with coupled-field finite element (FE) models are used to study the frequency response behavior of necked lugs. These numerical analyses include both pristine and cracked lug models. Through-cracks are located at 90 [Formula: see text] and 145 [Formula: see text] to the lug axis, which are critical spots for damage initiation. The results of FE simulations with a crack location at 90 [Formula: see text] are validated with experiments using an impedance analyzer and a scanning laser Doppler vibrometer. For both experiments, the lug specimen is excited and measured using a piezoelectric active wafer sensor in a frequency range of 1 kHz to 100 kHz. The dynamic response of both numerical calculations and experimental measurements show good agreement. To identify (i.e., detect, locate, and quantify) cracks in necked lugs a two-step analysis is performed. In the first step, a crack is detected data-based by calculating damage metrics between pristine and damaged state frequency spectra and comparing the resulting values to a pre-defined threshold. In the second step the location and size of the detected crack is identified by evaluation of specific resonance frequency shifts of the necked lug. Both the search for frequencies sensitive to through-cracks that allow a distinction between the two critical locations and the evaluation of the crack size are model-based. This two-step analysis based on the EMI method is demonstrated experimentally at the considered idealized necked lug, and thus, represents a promising way to reliably detect, locate and quantify fatigue cracks at critical locations of real necked double shear lugs. MDPI 2020-12-23 /pmc/articles/PMC7795087/ /pubmed/33374853 http://dx.doi.org/10.3390/s21010044 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Winklberger, Markus Kralovec, Christoph Humer, Christoph Heftberger, Peter Schagerl, Martin Crack Identification in Necked Double Shear Lugs by Means of the Electro-Mechanical Impedance Method |
title | Crack Identification in Necked Double Shear Lugs by Means of the Electro-Mechanical Impedance Method |
title_full | Crack Identification in Necked Double Shear Lugs by Means of the Electro-Mechanical Impedance Method |
title_fullStr | Crack Identification in Necked Double Shear Lugs by Means of the Electro-Mechanical Impedance Method |
title_full_unstemmed | Crack Identification in Necked Double Shear Lugs by Means of the Electro-Mechanical Impedance Method |
title_short | Crack Identification in Necked Double Shear Lugs by Means of the Electro-Mechanical Impedance Method |
title_sort | crack identification in necked double shear lugs by means of the electro-mechanical impedance method |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7795087/ https://www.ncbi.nlm.nih.gov/pubmed/33374853 http://dx.doi.org/10.3390/s21010044 |
work_keys_str_mv | AT winklbergermarkus crackidentificationinneckeddoubleshearlugsbymeansoftheelectromechanicalimpedancemethod AT kralovecchristoph crackidentificationinneckeddoubleshearlugsbymeansoftheelectromechanicalimpedancemethod AT humerchristoph crackidentificationinneckeddoubleshearlugsbymeansoftheelectromechanicalimpedancemethod AT heftbergerpeter crackidentificationinneckeddoubleshearlugsbymeansoftheelectromechanicalimpedancemethod AT schagerlmartin crackidentificationinneckeddoubleshearlugsbymeansoftheelectromechanicalimpedancemethod |