Cargando…

Crack Identification in Necked Double Shear Lugs by Means of the Electro-Mechanical Impedance Method

This contribution investigates fatigue crack detection, localization and quantification in idealized necked double shear lugs using piezoelectric transducers attached to the lug shaft and analyzed by the electro-mechanical impedance (EMI) method. The considered idealized necked lug sample has a simp...

Descripción completa

Detalles Bibliográficos
Autores principales: Winklberger, Markus, Kralovec, Christoph, Humer, Christoph, Heftberger, Peter, Schagerl, Martin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7795087/
https://www.ncbi.nlm.nih.gov/pubmed/33374853
http://dx.doi.org/10.3390/s21010044
_version_ 1783634361838469120
author Winklberger, Markus
Kralovec, Christoph
Humer, Christoph
Heftberger, Peter
Schagerl, Martin
author_facet Winklberger, Markus
Kralovec, Christoph
Humer, Christoph
Heftberger, Peter
Schagerl, Martin
author_sort Winklberger, Markus
collection PubMed
description This contribution investigates fatigue crack detection, localization and quantification in idealized necked double shear lugs using piezoelectric transducers attached to the lug shaft and analyzed by the electro-mechanical impedance (EMI) method. The considered idealized necked lug sample has a simplified geometry and does not includes the typical bearing. Numerical simulations with coupled-field finite element (FE) models are used to study the frequency response behavior of necked lugs. These numerical analyses include both pristine and cracked lug models. Through-cracks are located at 90 [Formula: see text] and 145 [Formula: see text] to the lug axis, which are critical spots for damage initiation. The results of FE simulations with a crack location at 90 [Formula: see text] are validated with experiments using an impedance analyzer and a scanning laser Doppler vibrometer. For both experiments, the lug specimen is excited and measured using a piezoelectric active wafer sensor in a frequency range of 1 kHz to 100 kHz. The dynamic response of both numerical calculations and experimental measurements show good agreement. To identify (i.e., detect, locate, and quantify) cracks in necked lugs a two-step analysis is performed. In the first step, a crack is detected data-based by calculating damage metrics between pristine and damaged state frequency spectra and comparing the resulting values to a pre-defined threshold. In the second step the location and size of the detected crack is identified by evaluation of specific resonance frequency shifts of the necked lug. Both the search for frequencies sensitive to through-cracks that allow a distinction between the two critical locations and the evaluation of the crack size are model-based. This two-step analysis based on the EMI method is demonstrated experimentally at the considered idealized necked lug, and thus, represents a promising way to reliably detect, locate and quantify fatigue cracks at critical locations of real necked double shear lugs.
format Online
Article
Text
id pubmed-7795087
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-77950872021-01-10 Crack Identification in Necked Double Shear Lugs by Means of the Electro-Mechanical Impedance Method Winklberger, Markus Kralovec, Christoph Humer, Christoph Heftberger, Peter Schagerl, Martin Sensors (Basel) Article This contribution investigates fatigue crack detection, localization and quantification in idealized necked double shear lugs using piezoelectric transducers attached to the lug shaft and analyzed by the electro-mechanical impedance (EMI) method. The considered idealized necked lug sample has a simplified geometry and does not includes the typical bearing. Numerical simulations with coupled-field finite element (FE) models are used to study the frequency response behavior of necked lugs. These numerical analyses include both pristine and cracked lug models. Through-cracks are located at 90 [Formula: see text] and 145 [Formula: see text] to the lug axis, which are critical spots for damage initiation. The results of FE simulations with a crack location at 90 [Formula: see text] are validated with experiments using an impedance analyzer and a scanning laser Doppler vibrometer. For both experiments, the lug specimen is excited and measured using a piezoelectric active wafer sensor in a frequency range of 1 kHz to 100 kHz. The dynamic response of both numerical calculations and experimental measurements show good agreement. To identify (i.e., detect, locate, and quantify) cracks in necked lugs a two-step analysis is performed. In the first step, a crack is detected data-based by calculating damage metrics between pristine and damaged state frequency spectra and comparing the resulting values to a pre-defined threshold. In the second step the location and size of the detected crack is identified by evaluation of specific resonance frequency shifts of the necked lug. Both the search for frequencies sensitive to through-cracks that allow a distinction between the two critical locations and the evaluation of the crack size are model-based. This two-step analysis based on the EMI method is demonstrated experimentally at the considered idealized necked lug, and thus, represents a promising way to reliably detect, locate and quantify fatigue cracks at critical locations of real necked double shear lugs. MDPI 2020-12-23 /pmc/articles/PMC7795087/ /pubmed/33374853 http://dx.doi.org/10.3390/s21010044 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Winklberger, Markus
Kralovec, Christoph
Humer, Christoph
Heftberger, Peter
Schagerl, Martin
Crack Identification in Necked Double Shear Lugs by Means of the Electro-Mechanical Impedance Method
title Crack Identification in Necked Double Shear Lugs by Means of the Electro-Mechanical Impedance Method
title_full Crack Identification in Necked Double Shear Lugs by Means of the Electro-Mechanical Impedance Method
title_fullStr Crack Identification in Necked Double Shear Lugs by Means of the Electro-Mechanical Impedance Method
title_full_unstemmed Crack Identification in Necked Double Shear Lugs by Means of the Electro-Mechanical Impedance Method
title_short Crack Identification in Necked Double Shear Lugs by Means of the Electro-Mechanical Impedance Method
title_sort crack identification in necked double shear lugs by means of the electro-mechanical impedance method
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7795087/
https://www.ncbi.nlm.nih.gov/pubmed/33374853
http://dx.doi.org/10.3390/s21010044
work_keys_str_mv AT winklbergermarkus crackidentificationinneckeddoubleshearlugsbymeansoftheelectromechanicalimpedancemethod
AT kralovecchristoph crackidentificationinneckeddoubleshearlugsbymeansoftheelectromechanicalimpedancemethod
AT humerchristoph crackidentificationinneckeddoubleshearlugsbymeansoftheelectromechanicalimpedancemethod
AT heftbergerpeter crackidentificationinneckeddoubleshearlugsbymeansoftheelectromechanicalimpedancemethod
AT schagerlmartin crackidentificationinneckeddoubleshearlugsbymeansoftheelectromechanicalimpedancemethod