Cargando…

A Numerical Model of a Perforated Microcantilever Covered with Cardiomyocytes to Improve the Performance of the Microcantilever Sensor

A few simple polymeric microsystems, such as microcantilever sensors, have recently been developed for the preliminary screening of cardiac toxicity. The microcantilever deflection produced by a change in the cardiomyocyte (CM) contraction force is important for understanding the mechanism of heart...

Descripción completa

Detalles Bibliográficos
Autores principales: Qiu, Bin, Li, Guangyong, Du, Jianke, Zhang, Aibing, Jin, Yuan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7795391/
https://www.ncbi.nlm.nih.gov/pubmed/33379322
http://dx.doi.org/10.3390/ma14010095
_version_ 1783634434044461056
author Qiu, Bin
Li, Guangyong
Du, Jianke
Zhang, Aibing
Jin, Yuan
author_facet Qiu, Bin
Li, Guangyong
Du, Jianke
Zhang, Aibing
Jin, Yuan
author_sort Qiu, Bin
collection PubMed
description A few simple polymeric microsystems, such as microcantilever sensors, have recently been developed for the preliminary screening of cardiac toxicity. The microcantilever deflection produced by a change in the cardiomyocyte (CM) contraction force is important for understanding the mechanism of heart failure. In this study, a new numerical model is proposed to analyze the contractile behavior of CMs cultured on a perforated microcantilever surface for improving the performance of the microcantilever sensor. First, the surface traction model is used to investigate the bending displacement of the plain microcantilever. In order to improve the bending effect, a new numerical model is developed to analyze the bending behavior of the perforated microcantilever covered with CMs. Compared with the designed molds, the latter yields better results. Finally, a simulation analysis is proposed based on a finite element method to verify the presence of a preformed mold. Moreover, the effects of various factors on the bending displacement, including microcantilever size, Young’s modulus, and porosity factor, are investigated. Both the simulation and numerical results have good consistency, and the maximum error between the numerical and simulation results is not more than 3.4%, even though the porosity factor reaches 0.147. The results show that the developed mold opens new avenues for CM microcantilever sensors to detect cardiac toxicity.
format Online
Article
Text
id pubmed-7795391
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-77953912021-01-10 A Numerical Model of a Perforated Microcantilever Covered with Cardiomyocytes to Improve the Performance of the Microcantilever Sensor Qiu, Bin Li, Guangyong Du, Jianke Zhang, Aibing Jin, Yuan Materials (Basel) Article A few simple polymeric microsystems, such as microcantilever sensors, have recently been developed for the preliminary screening of cardiac toxicity. The microcantilever deflection produced by a change in the cardiomyocyte (CM) contraction force is important for understanding the mechanism of heart failure. In this study, a new numerical model is proposed to analyze the contractile behavior of CMs cultured on a perforated microcantilever surface for improving the performance of the microcantilever sensor. First, the surface traction model is used to investigate the bending displacement of the plain microcantilever. In order to improve the bending effect, a new numerical model is developed to analyze the bending behavior of the perforated microcantilever covered with CMs. Compared with the designed molds, the latter yields better results. Finally, a simulation analysis is proposed based on a finite element method to verify the presence of a preformed mold. Moreover, the effects of various factors on the bending displacement, including microcantilever size, Young’s modulus, and porosity factor, are investigated. Both the simulation and numerical results have good consistency, and the maximum error between the numerical and simulation results is not more than 3.4%, even though the porosity factor reaches 0.147. The results show that the developed mold opens new avenues for CM microcantilever sensors to detect cardiac toxicity. MDPI 2020-12-28 /pmc/articles/PMC7795391/ /pubmed/33379322 http://dx.doi.org/10.3390/ma14010095 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Qiu, Bin
Li, Guangyong
Du, Jianke
Zhang, Aibing
Jin, Yuan
A Numerical Model of a Perforated Microcantilever Covered with Cardiomyocytes to Improve the Performance of the Microcantilever Sensor
title A Numerical Model of a Perforated Microcantilever Covered with Cardiomyocytes to Improve the Performance of the Microcantilever Sensor
title_full A Numerical Model of a Perforated Microcantilever Covered with Cardiomyocytes to Improve the Performance of the Microcantilever Sensor
title_fullStr A Numerical Model of a Perforated Microcantilever Covered with Cardiomyocytes to Improve the Performance of the Microcantilever Sensor
title_full_unstemmed A Numerical Model of a Perforated Microcantilever Covered with Cardiomyocytes to Improve the Performance of the Microcantilever Sensor
title_short A Numerical Model of a Perforated Microcantilever Covered with Cardiomyocytes to Improve the Performance of the Microcantilever Sensor
title_sort numerical model of a perforated microcantilever covered with cardiomyocytes to improve the performance of the microcantilever sensor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7795391/
https://www.ncbi.nlm.nih.gov/pubmed/33379322
http://dx.doi.org/10.3390/ma14010095
work_keys_str_mv AT qiubin anumericalmodelofaperforatedmicrocantilevercoveredwithcardiomyocytestoimprovetheperformanceofthemicrocantileversensor
AT liguangyong anumericalmodelofaperforatedmicrocantilevercoveredwithcardiomyocytestoimprovetheperformanceofthemicrocantileversensor
AT dujianke anumericalmodelofaperforatedmicrocantilevercoveredwithcardiomyocytestoimprovetheperformanceofthemicrocantileversensor
AT zhangaibing anumericalmodelofaperforatedmicrocantilevercoveredwithcardiomyocytestoimprovetheperformanceofthemicrocantileversensor
AT jinyuan anumericalmodelofaperforatedmicrocantilevercoveredwithcardiomyocytestoimprovetheperformanceofthemicrocantileversensor
AT qiubin numericalmodelofaperforatedmicrocantilevercoveredwithcardiomyocytestoimprovetheperformanceofthemicrocantileversensor
AT liguangyong numericalmodelofaperforatedmicrocantilevercoveredwithcardiomyocytestoimprovetheperformanceofthemicrocantileversensor
AT dujianke numericalmodelofaperforatedmicrocantilevercoveredwithcardiomyocytestoimprovetheperformanceofthemicrocantileversensor
AT zhangaibing numericalmodelofaperforatedmicrocantilevercoveredwithcardiomyocytestoimprovetheperformanceofthemicrocantileversensor
AT jinyuan numericalmodelofaperforatedmicrocantilevercoveredwithcardiomyocytestoimprovetheperformanceofthemicrocantileversensor