Cargando…
Investigation of Parameters Influencing Tubular-Shaped Chitosan-Hydroxyapatite Layer Electrodeposition
Tubular-shaped layer electrodeposition from chitosan-hydroxyapatite colloidal solutions has found application in the field of regeneration or replacement of cylindrical tissues and organs, especially peripheral nerve tissue regeneration. Nevertheless, the quantitative and qualitative characterisatio...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7796046/ https://www.ncbi.nlm.nih.gov/pubmed/33379393 http://dx.doi.org/10.3390/molecules26010104 |
_version_ | 1783634588823715840 |
---|---|
author | Mąkiewicz, Mariusz Wach, Radosław A. Nawrotek, Katarzyna |
author_facet | Mąkiewicz, Mariusz Wach, Radosław A. Nawrotek, Katarzyna |
author_sort | Mąkiewicz, Mariusz |
collection | PubMed |
description | Tubular-shaped layer electrodeposition from chitosan-hydroxyapatite colloidal solutions has found application in the field of regeneration or replacement of cylindrical tissues and organs, especially peripheral nerve tissue regeneration. Nevertheless, the quantitative and qualitative characterisation of this phenomenon has not been described. In this work, the colloidal systems are subjected to the action of an electric current initiated at different voltages. Parameters of the electrodeposition process (i.e., total charge exchanged, gas volume, and deposit thickness) are monitored over time. Deposit structures are investigated by scanning electron microscopy (SEM) and Fourier-transform infrared spectroscopy (FTIR). The value of voltage influences structural characteristics but not thickness of deposit for the process lasting at least 20 min. The calculated number of exchanged electrons for studied conditions suggests that the mechanism of deposit formation is governed not only by water electrolysis but also interactions between formed hydroxide ions and calcium ions coordinated by chitosan chains. |
format | Online Article Text |
id | pubmed-7796046 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-77960462021-01-10 Investigation of Parameters Influencing Tubular-Shaped Chitosan-Hydroxyapatite Layer Electrodeposition Mąkiewicz, Mariusz Wach, Radosław A. Nawrotek, Katarzyna Molecules Article Tubular-shaped layer electrodeposition from chitosan-hydroxyapatite colloidal solutions has found application in the field of regeneration or replacement of cylindrical tissues and organs, especially peripheral nerve tissue regeneration. Nevertheless, the quantitative and qualitative characterisation of this phenomenon has not been described. In this work, the colloidal systems are subjected to the action of an electric current initiated at different voltages. Parameters of the electrodeposition process (i.e., total charge exchanged, gas volume, and deposit thickness) are monitored over time. Deposit structures are investigated by scanning electron microscopy (SEM) and Fourier-transform infrared spectroscopy (FTIR). The value of voltage influences structural characteristics but not thickness of deposit for the process lasting at least 20 min. The calculated number of exchanged electrons for studied conditions suggests that the mechanism of deposit formation is governed not only by water electrolysis but also interactions between formed hydroxide ions and calcium ions coordinated by chitosan chains. MDPI 2020-12-28 /pmc/articles/PMC7796046/ /pubmed/33379393 http://dx.doi.org/10.3390/molecules26010104 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Mąkiewicz, Mariusz Wach, Radosław A. Nawrotek, Katarzyna Investigation of Parameters Influencing Tubular-Shaped Chitosan-Hydroxyapatite Layer Electrodeposition |
title | Investigation of Parameters Influencing Tubular-Shaped Chitosan-Hydroxyapatite Layer Electrodeposition |
title_full | Investigation of Parameters Influencing Tubular-Shaped Chitosan-Hydroxyapatite Layer Electrodeposition |
title_fullStr | Investigation of Parameters Influencing Tubular-Shaped Chitosan-Hydroxyapatite Layer Electrodeposition |
title_full_unstemmed | Investigation of Parameters Influencing Tubular-Shaped Chitosan-Hydroxyapatite Layer Electrodeposition |
title_short | Investigation of Parameters Influencing Tubular-Shaped Chitosan-Hydroxyapatite Layer Electrodeposition |
title_sort | investigation of parameters influencing tubular-shaped chitosan-hydroxyapatite layer electrodeposition |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7796046/ https://www.ncbi.nlm.nih.gov/pubmed/33379393 http://dx.doi.org/10.3390/molecules26010104 |
work_keys_str_mv | AT makiewiczmariusz investigationofparametersinfluencingtubularshapedchitosanhydroxyapatitelayerelectrodeposition AT wachradosława investigationofparametersinfluencingtubularshapedchitosanhydroxyapatitelayerelectrodeposition AT nawrotekkatarzyna investigationofparametersinfluencingtubularshapedchitosanhydroxyapatitelayerelectrodeposition |