Cargando…

Design and Evaluation of a New Resin-Filled GFRP Pipe Connection System for Butt Splicing of FRP Bars

Fiber-reinforced polymer (FRP) bars are one of the promising alternatives for steel bars used in concrete structures under corrosion or non-magnetic environments due to the unique physical properties of FRP materials. When compared with steel bars, FRP bars are difficult to be spliced in field appli...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Hui, Lian, Jie, Li, Jiaxing, Jia, Bin, Meng, Dong, Wu, Zhizhong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7796113/
https://www.ncbi.nlm.nih.gov/pubmed/33396430
http://dx.doi.org/10.3390/ma14010161
_version_ 1783634604583813120
author Huang, Hui
Lian, Jie
Li, Jiaxing
Jia, Bin
Meng, Dong
Wu, Zhizhong
author_facet Huang, Hui
Lian, Jie
Li, Jiaxing
Jia, Bin
Meng, Dong
Wu, Zhizhong
author_sort Huang, Hui
collection PubMed
description Fiber-reinforced polymer (FRP) bars are one of the promising alternatives for steel bars used in concrete structures under corrosion or non-magnetic environments due to the unique physical properties of FRP materials. When compared with steel bars, FRP bars are difficult to be spliced in field application due to their anisotropy and low shear and compressive strengths. In view of this, the paper presents a new non-metallic connection system (i.e., resin-filled glass fiber-reinforced polymer (GFRP) pipe connection system) for the butt splicing of FRP bars. With the proposed connection system and a simplified trilinear interfacial bond-slip model, a set of design formulas were derived based on the requirement that the proposed connection system should provide a load transfer capacity beyond the tensile capacity of the spliced FRP bars (i.e., to fulfill the high tensile strength of FRP materials). Besides, considering the fabrication error-induced load transfer capacity reduction of the connection system in field application, a correction factor was introduced in the paper to compensate for the reduced load transfer capacity by increasing the FRP bar anchorage length. At last, to estimate the effectiveness of the proposed connection system and the derived design formulas, nine specimens were fabricated with a kind of commercially available basalt fiber-reinforced polymer (BFRP) bars and the designed connection system and tested under unidirectional tension to study their tensile performance. With the comparison between the tested and theoretical results, the effectiveness of the proposed connection system and the derived design formulas are verified.
format Online
Article
Text
id pubmed-7796113
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-77961132021-01-10 Design and Evaluation of a New Resin-Filled GFRP Pipe Connection System for Butt Splicing of FRP Bars Huang, Hui Lian, Jie Li, Jiaxing Jia, Bin Meng, Dong Wu, Zhizhong Materials (Basel) Article Fiber-reinforced polymer (FRP) bars are one of the promising alternatives for steel bars used in concrete structures under corrosion or non-magnetic environments due to the unique physical properties of FRP materials. When compared with steel bars, FRP bars are difficult to be spliced in field application due to their anisotropy and low shear and compressive strengths. In view of this, the paper presents a new non-metallic connection system (i.e., resin-filled glass fiber-reinforced polymer (GFRP) pipe connection system) for the butt splicing of FRP bars. With the proposed connection system and a simplified trilinear interfacial bond-slip model, a set of design formulas were derived based on the requirement that the proposed connection system should provide a load transfer capacity beyond the tensile capacity of the spliced FRP bars (i.e., to fulfill the high tensile strength of FRP materials). Besides, considering the fabrication error-induced load transfer capacity reduction of the connection system in field application, a correction factor was introduced in the paper to compensate for the reduced load transfer capacity by increasing the FRP bar anchorage length. At last, to estimate the effectiveness of the proposed connection system and the derived design formulas, nine specimens were fabricated with a kind of commercially available basalt fiber-reinforced polymer (BFRP) bars and the designed connection system and tested under unidirectional tension to study their tensile performance. With the comparison between the tested and theoretical results, the effectiveness of the proposed connection system and the derived design formulas are verified. MDPI 2020-12-31 /pmc/articles/PMC7796113/ /pubmed/33396430 http://dx.doi.org/10.3390/ma14010161 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Huang, Hui
Lian, Jie
Li, Jiaxing
Jia, Bin
Meng, Dong
Wu, Zhizhong
Design and Evaluation of a New Resin-Filled GFRP Pipe Connection System for Butt Splicing of FRP Bars
title Design and Evaluation of a New Resin-Filled GFRP Pipe Connection System for Butt Splicing of FRP Bars
title_full Design and Evaluation of a New Resin-Filled GFRP Pipe Connection System for Butt Splicing of FRP Bars
title_fullStr Design and Evaluation of a New Resin-Filled GFRP Pipe Connection System for Butt Splicing of FRP Bars
title_full_unstemmed Design and Evaluation of a New Resin-Filled GFRP Pipe Connection System for Butt Splicing of FRP Bars
title_short Design and Evaluation of a New Resin-Filled GFRP Pipe Connection System for Butt Splicing of FRP Bars
title_sort design and evaluation of a new resin-filled gfrp pipe connection system for butt splicing of frp bars
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7796113/
https://www.ncbi.nlm.nih.gov/pubmed/33396430
http://dx.doi.org/10.3390/ma14010161
work_keys_str_mv AT huanghui designandevaluationofanewresinfilledgfrppipeconnectionsystemforbuttsplicingoffrpbars
AT lianjie designandevaluationofanewresinfilledgfrppipeconnectionsystemforbuttsplicingoffrpbars
AT lijiaxing designandevaluationofanewresinfilledgfrppipeconnectionsystemforbuttsplicingoffrpbars
AT jiabin designandevaluationofanewresinfilledgfrppipeconnectionsystemforbuttsplicingoffrpbars
AT mengdong designandevaluationofanewresinfilledgfrppipeconnectionsystemforbuttsplicingoffrpbars
AT wuzhizhong designandevaluationofanewresinfilledgfrppipeconnectionsystemforbuttsplicingoffrpbars