Cargando…
Three-Dimensional Quantification of Bone Mineral Density in the Distal Femur and Proximal Tibia Based on Computed Tomography: In Vitro Evaluation of an Extended Standardization Method
While alterations in bone mineral density (BMD) are of interest in a number of musculoskeletal conditions affecting the knee, their analysis is limited by a lack of tools able to take full advantage of modern imaging modalities. This study introduced a new method, combining computed tomography (CT)...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7796434/ https://www.ncbi.nlm.nih.gov/pubmed/33466413 http://dx.doi.org/10.3390/jcm10010160 |
_version_ | 1783634681238913024 |
---|---|
author | Babel, Hugo Omoumi, Patrick Cosendey, Killian Cadas, Hugues Jolles, Brigitte M. Favre, Julien |
author_facet | Babel, Hugo Omoumi, Patrick Cosendey, Killian Cadas, Hugues Jolles, Brigitte M. Favre, Julien |
author_sort | Babel, Hugo |
collection | PubMed |
description | While alterations in bone mineral density (BMD) are of interest in a number of musculoskeletal conditions affecting the knee, their analysis is limited by a lack of tools able to take full advantage of modern imaging modalities. This study introduced a new method, combining computed tomography (CT) and computational anatomy algorithms, to produce standardized three-dimensional BMD quantification in the distal femur and proximal tibia. The method was evaluated on ten cadaveric knees CT-scanned twice and processed following three different experimental settings to assess the influence of different scans and operators. The median reliability (intraclass correlation coefficient (ICC)) ranged from 0.96 to 0.99 and the median reproducibility (precision error (RMSSD)) ranged from 3.97 to 10.75 mg/cc for the different experimental settings. In conclusion, this paper presented a method to standardize three-dimensional knee BMD with excellent reliability and adequate reproducibility to be used in research and clinical applications. The perspectives offered by this novel method are further reinforced by the fact it relies on conventional CT scan of the knee. The standardization method introduced in this work is not limited to BMD and could be adapted to quantify other bone parameters in three dimension based on CT images or images acquired using different modalities. |
format | Online Article Text |
id | pubmed-7796434 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-77964342021-01-10 Three-Dimensional Quantification of Bone Mineral Density in the Distal Femur and Proximal Tibia Based on Computed Tomography: In Vitro Evaluation of an Extended Standardization Method Babel, Hugo Omoumi, Patrick Cosendey, Killian Cadas, Hugues Jolles, Brigitte M. Favre, Julien J Clin Med Article While alterations in bone mineral density (BMD) are of interest in a number of musculoskeletal conditions affecting the knee, their analysis is limited by a lack of tools able to take full advantage of modern imaging modalities. This study introduced a new method, combining computed tomography (CT) and computational anatomy algorithms, to produce standardized three-dimensional BMD quantification in the distal femur and proximal tibia. The method was evaluated on ten cadaveric knees CT-scanned twice and processed following three different experimental settings to assess the influence of different scans and operators. The median reliability (intraclass correlation coefficient (ICC)) ranged from 0.96 to 0.99 and the median reproducibility (precision error (RMSSD)) ranged from 3.97 to 10.75 mg/cc for the different experimental settings. In conclusion, this paper presented a method to standardize three-dimensional knee BMD with excellent reliability and adequate reproducibility to be used in research and clinical applications. The perspectives offered by this novel method are further reinforced by the fact it relies on conventional CT scan of the knee. The standardization method introduced in this work is not limited to BMD and could be adapted to quantify other bone parameters in three dimension based on CT images or images acquired using different modalities. MDPI 2021-01-05 /pmc/articles/PMC7796434/ /pubmed/33466413 http://dx.doi.org/10.3390/jcm10010160 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Babel, Hugo Omoumi, Patrick Cosendey, Killian Cadas, Hugues Jolles, Brigitte M. Favre, Julien Three-Dimensional Quantification of Bone Mineral Density in the Distal Femur and Proximal Tibia Based on Computed Tomography: In Vitro Evaluation of an Extended Standardization Method |
title | Three-Dimensional Quantification of Bone Mineral Density in the Distal Femur and Proximal Tibia Based on Computed Tomography: In Vitro Evaluation of an Extended Standardization Method |
title_full | Three-Dimensional Quantification of Bone Mineral Density in the Distal Femur and Proximal Tibia Based on Computed Tomography: In Vitro Evaluation of an Extended Standardization Method |
title_fullStr | Three-Dimensional Quantification of Bone Mineral Density in the Distal Femur and Proximal Tibia Based on Computed Tomography: In Vitro Evaluation of an Extended Standardization Method |
title_full_unstemmed | Three-Dimensional Quantification of Bone Mineral Density in the Distal Femur and Proximal Tibia Based on Computed Tomography: In Vitro Evaluation of an Extended Standardization Method |
title_short | Three-Dimensional Quantification of Bone Mineral Density in the Distal Femur and Proximal Tibia Based on Computed Tomography: In Vitro Evaluation of an Extended Standardization Method |
title_sort | three-dimensional quantification of bone mineral density in the distal femur and proximal tibia based on computed tomography: in vitro evaluation of an extended standardization method |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7796434/ https://www.ncbi.nlm.nih.gov/pubmed/33466413 http://dx.doi.org/10.3390/jcm10010160 |
work_keys_str_mv | AT babelhugo threedimensionalquantificationofbonemineraldensityinthedistalfemurandproximaltibiabasedoncomputedtomographyinvitroevaluationofanextendedstandardizationmethod AT omoumipatrick threedimensionalquantificationofbonemineraldensityinthedistalfemurandproximaltibiabasedoncomputedtomographyinvitroevaluationofanextendedstandardizationmethod AT cosendeykillian threedimensionalquantificationofbonemineraldensityinthedistalfemurandproximaltibiabasedoncomputedtomographyinvitroevaluationofanextendedstandardizationmethod AT cadashugues threedimensionalquantificationofbonemineraldensityinthedistalfemurandproximaltibiabasedoncomputedtomographyinvitroevaluationofanextendedstandardizationmethod AT jollesbrigittem threedimensionalquantificationofbonemineraldensityinthedistalfemurandproximaltibiabasedoncomputedtomographyinvitroevaluationofanextendedstandardizationmethod AT favrejulien threedimensionalquantificationofbonemineraldensityinthedistalfemurandproximaltibiabasedoncomputedtomographyinvitroevaluationofanextendedstandardizationmethod |