Cargando…

Patient and clinician satisfaction and clinical outcomes of Magseed compared with wire-guided localisation for impalpable breast lesions

BACKGROUND: Guide-wire localisation remains the most commonly used technique for localisation of impalpable breast lesions in the UK. One alternative is magnetic seed localisation. We aimed to investigate patient and clinician satisfaction in two consecutive cohorts, describe re-excision and positiv...

Descripción completa

Detalles Bibliográficos
Autores principales: Micha, Aikaterini E., Sinnett, Victoria, Downey, Kate, Allen, Steve, Bishop, Briony, Hector, Lauren R., Patrick, Elaine P., Edmonds, Ruth, Barry, Peter A., Krupa, Katherine D. C., Rusby, Jennifer E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Japan 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7796883/
https://www.ncbi.nlm.nih.gov/pubmed/32974810
http://dx.doi.org/10.1007/s12282-020-01149-1
_version_ 1783634773471657984
author Micha, Aikaterini E.
Sinnett, Victoria
Downey, Kate
Allen, Steve
Bishop, Briony
Hector, Lauren R.
Patrick, Elaine P.
Edmonds, Ruth
Barry, Peter A.
Krupa, Katherine D. C.
Rusby, Jennifer E.
author_facet Micha, Aikaterini E.
Sinnett, Victoria
Downey, Kate
Allen, Steve
Bishop, Briony
Hector, Lauren R.
Patrick, Elaine P.
Edmonds, Ruth
Barry, Peter A.
Krupa, Katherine D. C.
Rusby, Jennifer E.
author_sort Micha, Aikaterini E.
collection PubMed
description BACKGROUND: Guide-wire localisation remains the most commonly used technique for localisation of impalpable breast lesions in the UK. One alternative is magnetic seed localisation. We aimed to investigate patient and clinician satisfaction in two consecutive cohorts, describe re-excision and positive margin rates, and explore reasons for positive margins and the implications for localisation techniques. METHODS: A single-institution prospective service evaluation of two cohorts of consecutive cases of wire and then Magseed localisation was carried out. Data were collected on patient and clinician satisfaction, clinico-pathological findings, and causes of involved margins. T tests were used to compare continuous variables and Chi-squared test for satisfaction outcomes. RESULTS: 168 consecutive cases used wire-guided localisation (WGL) and 128 subsequent cases used Magseeds. Patients reported less anxiety between localisation and surgery in the Magseed group, and clinicians reported greater ease of use of Magseeds. There were no differences in lesion size, surgical complexity, or re-excision rate between the groups. In a subset of patients receiving standard wide local excision (i.e., excluding mammoplasties), the impact on margin involvement was investigated. There was no significant difference in radiological under-sizing or accuracy of localisation. However, specimen weight and eccentricity of the lesion were statistically significantly lower in the Magseed group. Despite this, re-excision rates were not significantly different (p = 0.4). CONCLUSIONS: This is the first large study of satisfaction with localisation and showed clinician preference for Magseed and a reduction in patient anxiety. It also demonstrated similar positive margin rates despite smaller specimen weights in the Magseed group. Magnetic seed localisation offers an acceptable clinical alternative to guide wire localisation. The impact on local service provision should also be considered.
format Online
Article
Text
id pubmed-7796883
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Japan
record_format MEDLINE/PubMed
spelling pubmed-77968832021-01-19 Patient and clinician satisfaction and clinical outcomes of Magseed compared with wire-guided localisation for impalpable breast lesions Micha, Aikaterini E. Sinnett, Victoria Downey, Kate Allen, Steve Bishop, Briony Hector, Lauren R. Patrick, Elaine P. Edmonds, Ruth Barry, Peter A. Krupa, Katherine D. C. Rusby, Jennifer E. Breast Cancer Original Article BACKGROUND: Guide-wire localisation remains the most commonly used technique for localisation of impalpable breast lesions in the UK. One alternative is magnetic seed localisation. We aimed to investigate patient and clinician satisfaction in two consecutive cohorts, describe re-excision and positive margin rates, and explore reasons for positive margins and the implications for localisation techniques. METHODS: A single-institution prospective service evaluation of two cohorts of consecutive cases of wire and then Magseed localisation was carried out. Data were collected on patient and clinician satisfaction, clinico-pathological findings, and causes of involved margins. T tests were used to compare continuous variables and Chi-squared test for satisfaction outcomes. RESULTS: 168 consecutive cases used wire-guided localisation (WGL) and 128 subsequent cases used Magseeds. Patients reported less anxiety between localisation and surgery in the Magseed group, and clinicians reported greater ease of use of Magseeds. There were no differences in lesion size, surgical complexity, or re-excision rate between the groups. In a subset of patients receiving standard wide local excision (i.e., excluding mammoplasties), the impact on margin involvement was investigated. There was no significant difference in radiological under-sizing or accuracy of localisation. However, specimen weight and eccentricity of the lesion were statistically significantly lower in the Magseed group. Despite this, re-excision rates were not significantly different (p = 0.4). CONCLUSIONS: This is the first large study of satisfaction with localisation and showed clinician preference for Magseed and a reduction in patient anxiety. It also demonstrated similar positive margin rates despite smaller specimen weights in the Magseed group. Magnetic seed localisation offers an acceptable clinical alternative to guide wire localisation. The impact on local service provision should also be considered. Springer Japan 2020-09-24 2021 /pmc/articles/PMC7796883/ /pubmed/32974810 http://dx.doi.org/10.1007/s12282-020-01149-1 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Original Article
Micha, Aikaterini E.
Sinnett, Victoria
Downey, Kate
Allen, Steve
Bishop, Briony
Hector, Lauren R.
Patrick, Elaine P.
Edmonds, Ruth
Barry, Peter A.
Krupa, Katherine D. C.
Rusby, Jennifer E.
Patient and clinician satisfaction and clinical outcomes of Magseed compared with wire-guided localisation for impalpable breast lesions
title Patient and clinician satisfaction and clinical outcomes of Magseed compared with wire-guided localisation for impalpable breast lesions
title_full Patient and clinician satisfaction and clinical outcomes of Magseed compared with wire-guided localisation for impalpable breast lesions
title_fullStr Patient and clinician satisfaction and clinical outcomes of Magseed compared with wire-guided localisation for impalpable breast lesions
title_full_unstemmed Patient and clinician satisfaction and clinical outcomes of Magseed compared with wire-guided localisation for impalpable breast lesions
title_short Patient and clinician satisfaction and clinical outcomes of Magseed compared with wire-guided localisation for impalpable breast lesions
title_sort patient and clinician satisfaction and clinical outcomes of magseed compared with wire-guided localisation for impalpable breast lesions
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7796883/
https://www.ncbi.nlm.nih.gov/pubmed/32974810
http://dx.doi.org/10.1007/s12282-020-01149-1
work_keys_str_mv AT michaaikaterinie patientandcliniciansatisfactionandclinicaloutcomesofmagseedcomparedwithwireguidedlocalisationforimpalpablebreastlesions
AT sinnettvictoria patientandcliniciansatisfactionandclinicaloutcomesofmagseedcomparedwithwireguidedlocalisationforimpalpablebreastlesions
AT downeykate patientandcliniciansatisfactionandclinicaloutcomesofmagseedcomparedwithwireguidedlocalisationforimpalpablebreastlesions
AT allensteve patientandcliniciansatisfactionandclinicaloutcomesofmagseedcomparedwithwireguidedlocalisationforimpalpablebreastlesions
AT bishopbriony patientandcliniciansatisfactionandclinicaloutcomesofmagseedcomparedwithwireguidedlocalisationforimpalpablebreastlesions
AT hectorlaurenr patientandcliniciansatisfactionandclinicaloutcomesofmagseedcomparedwithwireguidedlocalisationforimpalpablebreastlesions
AT patrickelainep patientandcliniciansatisfactionandclinicaloutcomesofmagseedcomparedwithwireguidedlocalisationforimpalpablebreastlesions
AT edmondsruth patientandcliniciansatisfactionandclinicaloutcomesofmagseedcomparedwithwireguidedlocalisationforimpalpablebreastlesions
AT barrypetera patientandcliniciansatisfactionandclinicaloutcomesofmagseedcomparedwithwireguidedlocalisationforimpalpablebreastlesions
AT krupakatherinedc patientandcliniciansatisfactionandclinicaloutcomesofmagseedcomparedwithwireguidedlocalisationforimpalpablebreastlesions
AT rusbyjennifere patientandcliniciansatisfactionandclinicaloutcomesofmagseedcomparedwithwireguidedlocalisationforimpalpablebreastlesions