Application of a roller conveyor type plasma disinfection device with fungus-contaminated citrus fruits
Efficient methods to achieve the safe decontamination of agricultural products are needed. Here, we investigated the decontamination of citrus fruits to test the antifungal potential of a novel non-thermal gas plasma apparatus, termed a roller conveyer plasma instrument. This instrument generates an...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7797019/ https://www.ncbi.nlm.nih.gov/pubmed/33423150 http://dx.doi.org/10.1186/s13568-020-01177-2 |
_version_ | 1783634784014041088 |
---|---|
author | Sakudo, Akikazu Yagyu, Yoshihito |
author_facet | Sakudo, Akikazu Yagyu, Yoshihito |
author_sort | Sakudo, Akikazu |
collection | PubMed |
description | Efficient methods to achieve the safe decontamination of agricultural products are needed. Here, we investigated the decontamination of citrus fruits to test the antifungal potential of a novel non-thermal gas plasma apparatus, termed a roller conveyer plasma instrument. This instrument generates an atmospheric pressure dielectric barrier discharge (APDBP) plasma on a set of rollers. Penicillium venetum was spotted onto the surface of the fruit or pericarps, as well as an aluminium plate to act as a control, before performing the plasma treatment. The results showed that viable cell number of P. venetum decreased with a decimal reduction time (D value or estimated treatment time required to reduce viable cell number by 90%) of 0.967 min on the aluminium plate, 2.90 min and 1.88 min on the pericarps of ‘Kiyomi’ (Citrus unshiu × C. sinensis) and ‘Kawano-natsudaidai’ (C. natsudaidai) respectively, and 2.42 min on the surface of ‘Unshu-mikan’ (C. unshiu). These findings confirmed a fungicidal effect of the plasma not only on an abiotic surface (aluminium plate) but also on a biotic surface (citrus fruit). Further development of the instrument by combining sorting systems with the plasma device promises an efficient means of disinfecting citrus fruits during food processing. |
format | Online Article Text |
id | pubmed-7797019 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-77970192021-01-19 Application of a roller conveyor type plasma disinfection device with fungus-contaminated citrus fruits Sakudo, Akikazu Yagyu, Yoshihito AMB Express Original Article Efficient methods to achieve the safe decontamination of agricultural products are needed. Here, we investigated the decontamination of citrus fruits to test the antifungal potential of a novel non-thermal gas plasma apparatus, termed a roller conveyer plasma instrument. This instrument generates an atmospheric pressure dielectric barrier discharge (APDBP) plasma on a set of rollers. Penicillium venetum was spotted onto the surface of the fruit or pericarps, as well as an aluminium plate to act as a control, before performing the plasma treatment. The results showed that viable cell number of P. venetum decreased with a decimal reduction time (D value or estimated treatment time required to reduce viable cell number by 90%) of 0.967 min on the aluminium plate, 2.90 min and 1.88 min on the pericarps of ‘Kiyomi’ (Citrus unshiu × C. sinensis) and ‘Kawano-natsudaidai’ (C. natsudaidai) respectively, and 2.42 min on the surface of ‘Unshu-mikan’ (C. unshiu). These findings confirmed a fungicidal effect of the plasma not only on an abiotic surface (aluminium plate) but also on a biotic surface (citrus fruit). Further development of the instrument by combining sorting systems with the plasma device promises an efficient means of disinfecting citrus fruits during food processing. Springer Berlin Heidelberg 2021-01-09 /pmc/articles/PMC7797019/ /pubmed/33423150 http://dx.doi.org/10.1186/s13568-020-01177-2 Text en © The Author(s) 2021 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Original Article Sakudo, Akikazu Yagyu, Yoshihito Application of a roller conveyor type plasma disinfection device with fungus-contaminated citrus fruits |
title | Application of a roller conveyor type plasma disinfection device with fungus-contaminated citrus fruits |
title_full | Application of a roller conveyor type plasma disinfection device with fungus-contaminated citrus fruits |
title_fullStr | Application of a roller conveyor type plasma disinfection device with fungus-contaminated citrus fruits |
title_full_unstemmed | Application of a roller conveyor type plasma disinfection device with fungus-contaminated citrus fruits |
title_short | Application of a roller conveyor type plasma disinfection device with fungus-contaminated citrus fruits |
title_sort | application of a roller conveyor type plasma disinfection device with fungus-contaminated citrus fruits |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7797019/ https://www.ncbi.nlm.nih.gov/pubmed/33423150 http://dx.doi.org/10.1186/s13568-020-01177-2 |
work_keys_str_mv | AT sakudoakikazu applicationofarollerconveyortypeplasmadisinfectiondevicewithfunguscontaminatedcitrusfruits AT yagyuyoshihito applicationofarollerconveyortypeplasmadisinfectiondevicewithfunguscontaminatedcitrusfruits |