Cargando…
Reliability of circulating fibrinogen in the diagnosis of prosthesis-related infections: a systematic review and meta-analysis
BACKGROUND: Fibrinogen (FIB) has recently been used as a biomarker to diagnose periprosthetic joint infection (PJI), but its reliability is still questionable. The aim of this study was to investigate the accuracy of FIB in the diagnosis of PJI after joint replacement. METHODS: We searched for liter...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7797116/ https://www.ncbi.nlm.nih.gov/pubmed/33422111 http://dx.doi.org/10.1186/s13018-020-02171-x |
_version_ | 1783634805186887680 |
---|---|
author | Zhu, Xingyang Zhang, Haitao Sun, Xiaobo Li, Yijin Li, Jiahao Zeng, Yuqing Deng, Peng Qi, Xinyu Chen, Jinlun Ye, Pengcheng Feng, Wenjun Li, Jie Zeng, Jianchun Zeng, Yirong |
author_facet | Zhu, Xingyang Zhang, Haitao Sun, Xiaobo Li, Yijin Li, Jiahao Zeng, Yuqing Deng, Peng Qi, Xinyu Chen, Jinlun Ye, Pengcheng Feng, Wenjun Li, Jie Zeng, Jianchun Zeng, Yirong |
author_sort | Zhu, Xingyang |
collection | PubMed |
description | BACKGROUND: Fibrinogen (FIB) has recently been used as a biomarker to diagnose periprosthetic joint infection (PJI), but its reliability is still questionable. The aim of this study was to investigate the accuracy of FIB in the diagnosis of PJI after joint replacement. METHODS: We searched for literatures published in PubMed, EMBASE, and the Cochrane Library from the time of database inception to September 2020 and screened the studies according to the inclusion criteria. Then, we calculated the diagnostic parameters of FIB, including the pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), area under the curve (AUC), and diagnostic odds ratio (DOR). In addition, we implemented subgroup analyses to identify the sources of heterogeneity. RESULTS: Seven studies including 1341 patients were selected in our meta-analysis. The pooled sensitivity, specificity, PLR, NLR, and DOR of FIB for PJI diagnosis were 0.78 (95% confidence interval [CI], 0.73–0.82), 0.83 (95% CI, 0.81–0.86), 4.60 (95% CI, 3.30–6.42), 0.24 (95% CI, 0.18–0.34), and 20.13 (95% CI, 14.80–27.36), respectively, while the AUC was 0.896. CONCLUSION: The present study indicated that FIB was a reliable detection method and might be introduced into the diagnostic criteria for PJI. However, more robust studies are still needed to confirm the current findings, because most of the included studies were retrospective and had small sample sizes. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13018-020-02171-x. |
format | Online Article Text |
id | pubmed-7797116 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-77971162021-01-11 Reliability of circulating fibrinogen in the diagnosis of prosthesis-related infections: a systematic review and meta-analysis Zhu, Xingyang Zhang, Haitao Sun, Xiaobo Li, Yijin Li, Jiahao Zeng, Yuqing Deng, Peng Qi, Xinyu Chen, Jinlun Ye, Pengcheng Feng, Wenjun Li, Jie Zeng, Jianchun Zeng, Yirong J Orthop Surg Res Research Article BACKGROUND: Fibrinogen (FIB) has recently been used as a biomarker to diagnose periprosthetic joint infection (PJI), but its reliability is still questionable. The aim of this study was to investigate the accuracy of FIB in the diagnosis of PJI after joint replacement. METHODS: We searched for literatures published in PubMed, EMBASE, and the Cochrane Library from the time of database inception to September 2020 and screened the studies according to the inclusion criteria. Then, we calculated the diagnostic parameters of FIB, including the pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), area under the curve (AUC), and diagnostic odds ratio (DOR). In addition, we implemented subgroup analyses to identify the sources of heterogeneity. RESULTS: Seven studies including 1341 patients were selected in our meta-analysis. The pooled sensitivity, specificity, PLR, NLR, and DOR of FIB for PJI diagnosis were 0.78 (95% confidence interval [CI], 0.73–0.82), 0.83 (95% CI, 0.81–0.86), 4.60 (95% CI, 3.30–6.42), 0.24 (95% CI, 0.18–0.34), and 20.13 (95% CI, 14.80–27.36), respectively, while the AUC was 0.896. CONCLUSION: The present study indicated that FIB was a reliable detection method and might be introduced into the diagnostic criteria for PJI. However, more robust studies are still needed to confirm the current findings, because most of the included studies were retrospective and had small sample sizes. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13018-020-02171-x. BioMed Central 2021-01-09 /pmc/articles/PMC7797116/ /pubmed/33422111 http://dx.doi.org/10.1186/s13018-020-02171-x Text en © The Author(s) 2021 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Zhu, Xingyang Zhang, Haitao Sun, Xiaobo Li, Yijin Li, Jiahao Zeng, Yuqing Deng, Peng Qi, Xinyu Chen, Jinlun Ye, Pengcheng Feng, Wenjun Li, Jie Zeng, Jianchun Zeng, Yirong Reliability of circulating fibrinogen in the diagnosis of prosthesis-related infections: a systematic review and meta-analysis |
title | Reliability of circulating fibrinogen in the diagnosis of prosthesis-related infections: a systematic review and meta-analysis |
title_full | Reliability of circulating fibrinogen in the diagnosis of prosthesis-related infections: a systematic review and meta-analysis |
title_fullStr | Reliability of circulating fibrinogen in the diagnosis of prosthesis-related infections: a systematic review and meta-analysis |
title_full_unstemmed | Reliability of circulating fibrinogen in the diagnosis of prosthesis-related infections: a systematic review and meta-analysis |
title_short | Reliability of circulating fibrinogen in the diagnosis of prosthesis-related infections: a systematic review and meta-analysis |
title_sort | reliability of circulating fibrinogen in the diagnosis of prosthesis-related infections: a systematic review and meta-analysis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7797116/ https://www.ncbi.nlm.nih.gov/pubmed/33422111 http://dx.doi.org/10.1186/s13018-020-02171-x |
work_keys_str_mv | AT zhuxingyang reliabilityofcirculatingfibrinogeninthediagnosisofprosthesisrelatedinfectionsasystematicreviewandmetaanalysis AT zhanghaitao reliabilityofcirculatingfibrinogeninthediagnosisofprosthesisrelatedinfectionsasystematicreviewandmetaanalysis AT sunxiaobo reliabilityofcirculatingfibrinogeninthediagnosisofprosthesisrelatedinfectionsasystematicreviewandmetaanalysis AT liyijin reliabilityofcirculatingfibrinogeninthediagnosisofprosthesisrelatedinfectionsasystematicreviewandmetaanalysis AT lijiahao reliabilityofcirculatingfibrinogeninthediagnosisofprosthesisrelatedinfectionsasystematicreviewandmetaanalysis AT zengyuqing reliabilityofcirculatingfibrinogeninthediagnosisofprosthesisrelatedinfectionsasystematicreviewandmetaanalysis AT dengpeng reliabilityofcirculatingfibrinogeninthediagnosisofprosthesisrelatedinfectionsasystematicreviewandmetaanalysis AT qixinyu reliabilityofcirculatingfibrinogeninthediagnosisofprosthesisrelatedinfectionsasystematicreviewandmetaanalysis AT chenjinlun reliabilityofcirculatingfibrinogeninthediagnosisofprosthesisrelatedinfectionsasystematicreviewandmetaanalysis AT yepengcheng reliabilityofcirculatingfibrinogeninthediagnosisofprosthesisrelatedinfectionsasystematicreviewandmetaanalysis AT fengwenjun reliabilityofcirculatingfibrinogeninthediagnosisofprosthesisrelatedinfectionsasystematicreviewandmetaanalysis AT lijie reliabilityofcirculatingfibrinogeninthediagnosisofprosthesisrelatedinfectionsasystematicreviewandmetaanalysis AT zengjianchun reliabilityofcirculatingfibrinogeninthediagnosisofprosthesisrelatedinfectionsasystematicreviewandmetaanalysis AT zengyirong reliabilityofcirculatingfibrinogeninthediagnosisofprosthesisrelatedinfectionsasystematicreviewandmetaanalysis |