Cargando…
Fingerprint analysis of phenolic acid extract of Salvia miltiorrhiza by digital reference standard analyzer with one or two reference standards
BACKGROUND: Fingerprint analysis and simultaneous multi-components determination are crucial for the holistic quality control of traditional Chinese medicines (TCMs). Yet, reference standards (RS) are often commercially unavailable and with other shortages, which severely impede the application of t...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7798244/ https://www.ncbi.nlm.nih.gov/pubmed/33430914 http://dx.doi.org/10.1186/s13020-020-00408-9 |
_version_ | 1783635023884189696 |
---|---|
author | Wang, Qingjun Yu, Xinlan Sun, Lei Tian, Runtao He, Huaizhen Wang, Sicen Ma, Shuangcheng |
author_facet | Wang, Qingjun Yu, Xinlan Sun, Lei Tian, Runtao He, Huaizhen Wang, Sicen Ma, Shuangcheng |
author_sort | Wang, Qingjun |
collection | PubMed |
description | BACKGROUND: Fingerprint analysis and simultaneous multi-components determination are crucial for the holistic quality control of traditional Chinese medicines (TCMs). Yet, reference standards (RS) are often commercially unavailable and with other shortages, which severely impede the application of these technologies. METHODS: A digital reference standard (DRS) strategy and the corresponding software called DRS analyzer, which supports chromatographic algorithms, spectrum algorithms, and the combination of these algorithms, was developed. The extensive function also enabled the DRS analyzer to recommend the chromatographic column based on big data. RESULTS: Various quality control methods of fingerprints of 11 compounds in polyphenolic acid extract of Salvia miltiorrhiza (S. miltiorrhiza) were developed based on DRS analyzer, involving relative retention time (RRT) method, linear calibration using two reference substances (LCTRS) technique, RRT combined with Photon Diode Array (PDA) method, LCTRS combined with PDA method. Additionally, the column database of samples was established. Finally, our data demonstrated that the DRS analyzer could accurately identify 11 compounds of the samples, using only one or two physical RSs. CONCLUSIONS: The DRS strategy is an automated, intelligent, objective, accurate, eco-friendly, universal, sharing, and promising method for overall quality control of TCMs that requires the usage of fewer RSs. |
format | Online Article Text |
id | pubmed-7798244 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-77982442021-01-11 Fingerprint analysis of phenolic acid extract of Salvia miltiorrhiza by digital reference standard analyzer with one or two reference standards Wang, Qingjun Yu, Xinlan Sun, Lei Tian, Runtao He, Huaizhen Wang, Sicen Ma, Shuangcheng Chin Med Research BACKGROUND: Fingerprint analysis and simultaneous multi-components determination are crucial for the holistic quality control of traditional Chinese medicines (TCMs). Yet, reference standards (RS) are often commercially unavailable and with other shortages, which severely impede the application of these technologies. METHODS: A digital reference standard (DRS) strategy and the corresponding software called DRS analyzer, which supports chromatographic algorithms, spectrum algorithms, and the combination of these algorithms, was developed. The extensive function also enabled the DRS analyzer to recommend the chromatographic column based on big data. RESULTS: Various quality control methods of fingerprints of 11 compounds in polyphenolic acid extract of Salvia miltiorrhiza (S. miltiorrhiza) were developed based on DRS analyzer, involving relative retention time (RRT) method, linear calibration using two reference substances (LCTRS) technique, RRT combined with Photon Diode Array (PDA) method, LCTRS combined with PDA method. Additionally, the column database of samples was established. Finally, our data demonstrated that the DRS analyzer could accurately identify 11 compounds of the samples, using only one or two physical RSs. CONCLUSIONS: The DRS strategy is an automated, intelligent, objective, accurate, eco-friendly, universal, sharing, and promising method for overall quality control of TCMs that requires the usage of fewer RSs. BioMed Central 2021-01-11 /pmc/articles/PMC7798244/ /pubmed/33430914 http://dx.doi.org/10.1186/s13020-020-00408-9 Text en © The Author(s) 2021 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Wang, Qingjun Yu, Xinlan Sun, Lei Tian, Runtao He, Huaizhen Wang, Sicen Ma, Shuangcheng Fingerprint analysis of phenolic acid extract of Salvia miltiorrhiza by digital reference standard analyzer with one or two reference standards |
title | Fingerprint analysis of phenolic acid extract of Salvia miltiorrhiza by digital reference standard analyzer with one or two reference standards |
title_full | Fingerprint analysis of phenolic acid extract of Salvia miltiorrhiza by digital reference standard analyzer with one or two reference standards |
title_fullStr | Fingerprint analysis of phenolic acid extract of Salvia miltiorrhiza by digital reference standard analyzer with one or two reference standards |
title_full_unstemmed | Fingerprint analysis of phenolic acid extract of Salvia miltiorrhiza by digital reference standard analyzer with one or two reference standards |
title_short | Fingerprint analysis of phenolic acid extract of Salvia miltiorrhiza by digital reference standard analyzer with one or two reference standards |
title_sort | fingerprint analysis of phenolic acid extract of salvia miltiorrhiza by digital reference standard analyzer with one or two reference standards |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7798244/ https://www.ncbi.nlm.nih.gov/pubmed/33430914 http://dx.doi.org/10.1186/s13020-020-00408-9 |
work_keys_str_mv | AT wangqingjun fingerprintanalysisofphenolicacidextractofsalviamiltiorrhizabydigitalreferencestandardanalyzerwithoneortworeferencestandards AT yuxinlan fingerprintanalysisofphenolicacidextractofsalviamiltiorrhizabydigitalreferencestandardanalyzerwithoneortworeferencestandards AT sunlei fingerprintanalysisofphenolicacidextractofsalviamiltiorrhizabydigitalreferencestandardanalyzerwithoneortworeferencestandards AT tianruntao fingerprintanalysisofphenolicacidextractofsalviamiltiorrhizabydigitalreferencestandardanalyzerwithoneortworeferencestandards AT hehuaizhen fingerprintanalysisofphenolicacidextractofsalviamiltiorrhizabydigitalreferencestandardanalyzerwithoneortworeferencestandards AT wangsicen fingerprintanalysisofphenolicacidextractofsalviamiltiorrhizabydigitalreferencestandardanalyzerwithoneortworeferencestandards AT mashuangcheng fingerprintanalysisofphenolicacidextractofsalviamiltiorrhizabydigitalreferencestandardanalyzerwithoneortworeferencestandards |