Cargando…

Fingerprint analysis of phenolic acid extract of Salvia miltiorrhiza by digital reference standard analyzer with one or two reference standards

BACKGROUND: Fingerprint analysis and simultaneous multi-components determination are crucial for the holistic quality control of traditional Chinese medicines (TCMs). Yet, reference standards (RS) are often commercially unavailable and with other shortages, which severely impede the application of t...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Qingjun, Yu, Xinlan, Sun, Lei, Tian, Runtao, He, Huaizhen, Wang, Sicen, Ma, Shuangcheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7798244/
https://www.ncbi.nlm.nih.gov/pubmed/33430914
http://dx.doi.org/10.1186/s13020-020-00408-9
_version_ 1783635023884189696
author Wang, Qingjun
Yu, Xinlan
Sun, Lei
Tian, Runtao
He, Huaizhen
Wang, Sicen
Ma, Shuangcheng
author_facet Wang, Qingjun
Yu, Xinlan
Sun, Lei
Tian, Runtao
He, Huaizhen
Wang, Sicen
Ma, Shuangcheng
author_sort Wang, Qingjun
collection PubMed
description BACKGROUND: Fingerprint analysis and simultaneous multi-components determination are crucial for the holistic quality control of traditional Chinese medicines (TCMs). Yet, reference standards (RS) are often commercially unavailable and with other shortages, which severely impede the application of these technologies. METHODS: A digital reference standard (DRS) strategy and the corresponding software called DRS analyzer, which supports chromatographic algorithms, spectrum algorithms, and the combination of these algorithms, was developed. The extensive function also enabled the DRS analyzer to recommend the chromatographic column based on big data. RESULTS: Various quality control methods of fingerprints of 11 compounds in polyphenolic acid extract of Salvia miltiorrhiza (S. miltiorrhiza) were developed based on DRS analyzer, involving relative retention time (RRT) method, linear calibration using two reference substances (LCTRS) technique, RRT combined with Photon Diode Array (PDA) method, LCTRS combined with PDA method. Additionally, the column database of samples was established. Finally, our data demonstrated that the DRS analyzer could accurately identify 11 compounds of the samples, using only one or two physical RSs. CONCLUSIONS: The DRS strategy is an automated, intelligent, objective, accurate, eco-friendly, universal, sharing, and promising method for overall quality control of TCMs that requires the usage of fewer RSs.
format Online
Article
Text
id pubmed-7798244
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-77982442021-01-11 Fingerprint analysis of phenolic acid extract of Salvia miltiorrhiza by digital reference standard analyzer with one or two reference standards Wang, Qingjun Yu, Xinlan Sun, Lei Tian, Runtao He, Huaizhen Wang, Sicen Ma, Shuangcheng Chin Med Research BACKGROUND: Fingerprint analysis and simultaneous multi-components determination are crucial for the holistic quality control of traditional Chinese medicines (TCMs). Yet, reference standards (RS) are often commercially unavailable and with other shortages, which severely impede the application of these technologies. METHODS: A digital reference standard (DRS) strategy and the corresponding software called DRS analyzer, which supports chromatographic algorithms, spectrum algorithms, and the combination of these algorithms, was developed. The extensive function also enabled the DRS analyzer to recommend the chromatographic column based on big data. RESULTS: Various quality control methods of fingerprints of 11 compounds in polyphenolic acid extract of Salvia miltiorrhiza (S. miltiorrhiza) were developed based on DRS analyzer, involving relative retention time (RRT) method, linear calibration using two reference substances (LCTRS) technique, RRT combined with Photon Diode Array (PDA) method, LCTRS combined with PDA method. Additionally, the column database of samples was established. Finally, our data demonstrated that the DRS analyzer could accurately identify 11 compounds of the samples, using only one or two physical RSs. CONCLUSIONS: The DRS strategy is an automated, intelligent, objective, accurate, eco-friendly, universal, sharing, and promising method for overall quality control of TCMs that requires the usage of fewer RSs. BioMed Central 2021-01-11 /pmc/articles/PMC7798244/ /pubmed/33430914 http://dx.doi.org/10.1186/s13020-020-00408-9 Text en © The Author(s) 2021 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Wang, Qingjun
Yu, Xinlan
Sun, Lei
Tian, Runtao
He, Huaizhen
Wang, Sicen
Ma, Shuangcheng
Fingerprint analysis of phenolic acid extract of Salvia miltiorrhiza by digital reference standard analyzer with one or two reference standards
title Fingerprint analysis of phenolic acid extract of Salvia miltiorrhiza by digital reference standard analyzer with one or two reference standards
title_full Fingerprint analysis of phenolic acid extract of Salvia miltiorrhiza by digital reference standard analyzer with one or two reference standards
title_fullStr Fingerprint analysis of phenolic acid extract of Salvia miltiorrhiza by digital reference standard analyzer with one or two reference standards
title_full_unstemmed Fingerprint analysis of phenolic acid extract of Salvia miltiorrhiza by digital reference standard analyzer with one or two reference standards
title_short Fingerprint analysis of phenolic acid extract of Salvia miltiorrhiza by digital reference standard analyzer with one or two reference standards
title_sort fingerprint analysis of phenolic acid extract of salvia miltiorrhiza by digital reference standard analyzer with one or two reference standards
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7798244/
https://www.ncbi.nlm.nih.gov/pubmed/33430914
http://dx.doi.org/10.1186/s13020-020-00408-9
work_keys_str_mv AT wangqingjun fingerprintanalysisofphenolicacidextractofsalviamiltiorrhizabydigitalreferencestandardanalyzerwithoneortworeferencestandards
AT yuxinlan fingerprintanalysisofphenolicacidextractofsalviamiltiorrhizabydigitalreferencestandardanalyzerwithoneortworeferencestandards
AT sunlei fingerprintanalysisofphenolicacidextractofsalviamiltiorrhizabydigitalreferencestandardanalyzerwithoneortworeferencestandards
AT tianruntao fingerprintanalysisofphenolicacidextractofsalviamiltiorrhizabydigitalreferencestandardanalyzerwithoneortworeferencestandards
AT hehuaizhen fingerprintanalysisofphenolicacidextractofsalviamiltiorrhizabydigitalreferencestandardanalyzerwithoneortworeferencestandards
AT wangsicen fingerprintanalysisofphenolicacidextractofsalviamiltiorrhizabydigitalreferencestandardanalyzerwithoneortworeferencestandards
AT mashuangcheng fingerprintanalysisofphenolicacidextractofsalviamiltiorrhizabydigitalreferencestandardanalyzerwithoneortworeferencestandards