Cargando…
Self-Collected Oral Fluid Saliva Is Insensitive Compared With Nasal-Oropharyngeal Swabs in the Detection of Severe Acute Respiratory Syndrome Coronavirus 2 in Outpatients
BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic control will require widespread access to accurate diagnostics. Salivary sampling circumvents swab supply chain bottlenecks, is amenable to self-collection, and is less likely to create an aerosol during collection com...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7798743/ https://www.ncbi.nlm.nih.gov/pubmed/33604399 http://dx.doi.org/10.1093/ofid/ofaa648 |
_version_ | 1783635082215424000 |
---|---|
author | Manabe, Yukari C Reuland, Carolyn Yu, Tong Azamfirei, Razvan Hardick, Justin P Church, Taylor Brown, Diane M Sewell, Thelio T Antar, Annuka Blair, Paul W Heaney, Chris D Pekosz, Andrew Thomas, David L |
author_facet | Manabe, Yukari C Reuland, Carolyn Yu, Tong Azamfirei, Razvan Hardick, Justin P Church, Taylor Brown, Diane M Sewell, Thelio T Antar, Annuka Blair, Paul W Heaney, Chris D Pekosz, Andrew Thomas, David L |
author_sort | Manabe, Yukari C |
collection | PubMed |
description | BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic control will require widespread access to accurate diagnostics. Salivary sampling circumvents swab supply chain bottlenecks, is amenable to self-collection, and is less likely to create an aerosol during collection compared with the nasopharyngeal swab. METHODS: We compared real-time reverse-transcription polymerase chain reaction Abbott m2000 results from matched salivary oral fluid (gingival crevicular fluid collected in an Oracol device) and nasal-oropharyngeal (OP) self-collected specimens in viral transport media from a nonhospitalized, ambulatory cohort of coronavirus disease 2019 (COVID-19) patients at multiple time points. These 2 sentences should be at the beginning of the results. RESULTS: There were 171 matched specimen pairs. Compared with nasal-OP swabs, 41.6% of the oral fluid samples were positive. Adding spit to the oral fluid percent collection device increased the percent positive agreement from 37.2% (16 of 43) to 44.6% (29 of 65). The positive percent agreement was highest in the first 5 days after symptoms and decreased thereafter. All of the infectious nasal-OP samples (culture positive on VeroE6 TMPRSS2 cells) had a matched SARS-CoV-2 positive oral fluid sample. CONCLUSIONS: In this study of nonhospitalized SARS-CoV-2-infected persons, we demonstrate lower diagnostic sensitivity of self-collected oral fluid compared with nasal-OP specimens, a difference that was especially prominent more than 5 days from symptom onset. These data do not justify the routine use of oral fluid collection for diagnosis of SARS-CoV-2 despite the greater ease of collection. It also underscores the importance of considering the method of saliva specimen collection and the time from symptom onset especially in outpatient populations. |
format | Online Article Text |
id | pubmed-7798743 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-77987432021-01-25 Self-Collected Oral Fluid Saliva Is Insensitive Compared With Nasal-Oropharyngeal Swabs in the Detection of Severe Acute Respiratory Syndrome Coronavirus 2 in Outpatients Manabe, Yukari C Reuland, Carolyn Yu, Tong Azamfirei, Razvan Hardick, Justin P Church, Taylor Brown, Diane M Sewell, Thelio T Antar, Annuka Blair, Paul W Heaney, Chris D Pekosz, Andrew Thomas, David L Open Forum Infect Dis Major Articles BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic control will require widespread access to accurate diagnostics. Salivary sampling circumvents swab supply chain bottlenecks, is amenable to self-collection, and is less likely to create an aerosol during collection compared with the nasopharyngeal swab. METHODS: We compared real-time reverse-transcription polymerase chain reaction Abbott m2000 results from matched salivary oral fluid (gingival crevicular fluid collected in an Oracol device) and nasal-oropharyngeal (OP) self-collected specimens in viral transport media from a nonhospitalized, ambulatory cohort of coronavirus disease 2019 (COVID-19) patients at multiple time points. These 2 sentences should be at the beginning of the results. RESULTS: There were 171 matched specimen pairs. Compared with nasal-OP swabs, 41.6% of the oral fluid samples were positive. Adding spit to the oral fluid percent collection device increased the percent positive agreement from 37.2% (16 of 43) to 44.6% (29 of 65). The positive percent agreement was highest in the first 5 days after symptoms and decreased thereafter. All of the infectious nasal-OP samples (culture positive on VeroE6 TMPRSS2 cells) had a matched SARS-CoV-2 positive oral fluid sample. CONCLUSIONS: In this study of nonhospitalized SARS-CoV-2-infected persons, we demonstrate lower diagnostic sensitivity of self-collected oral fluid compared with nasal-OP specimens, a difference that was especially prominent more than 5 days from symptom onset. These data do not justify the routine use of oral fluid collection for diagnosis of SARS-CoV-2 despite the greater ease of collection. It also underscores the importance of considering the method of saliva specimen collection and the time from symptom onset especially in outpatient populations. Oxford University Press 2020-12-30 /pmc/articles/PMC7798743/ /pubmed/33604399 http://dx.doi.org/10.1093/ofid/ofaa648 Text en © The Author(s) 2020. Published by Oxford University Press on behalf of Infectious Diseases Society of America. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (http://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Major Articles Manabe, Yukari C Reuland, Carolyn Yu, Tong Azamfirei, Razvan Hardick, Justin P Church, Taylor Brown, Diane M Sewell, Thelio T Antar, Annuka Blair, Paul W Heaney, Chris D Pekosz, Andrew Thomas, David L Self-Collected Oral Fluid Saliva Is Insensitive Compared With Nasal-Oropharyngeal Swabs in the Detection of Severe Acute Respiratory Syndrome Coronavirus 2 in Outpatients |
title | Self-Collected Oral Fluid Saliva Is Insensitive Compared With Nasal-Oropharyngeal Swabs in the Detection of Severe Acute Respiratory Syndrome Coronavirus 2 in Outpatients |
title_full | Self-Collected Oral Fluid Saliva Is Insensitive Compared With Nasal-Oropharyngeal Swabs in the Detection of Severe Acute Respiratory Syndrome Coronavirus 2 in Outpatients |
title_fullStr | Self-Collected Oral Fluid Saliva Is Insensitive Compared With Nasal-Oropharyngeal Swabs in the Detection of Severe Acute Respiratory Syndrome Coronavirus 2 in Outpatients |
title_full_unstemmed | Self-Collected Oral Fluid Saliva Is Insensitive Compared With Nasal-Oropharyngeal Swabs in the Detection of Severe Acute Respiratory Syndrome Coronavirus 2 in Outpatients |
title_short | Self-Collected Oral Fluid Saliva Is Insensitive Compared With Nasal-Oropharyngeal Swabs in the Detection of Severe Acute Respiratory Syndrome Coronavirus 2 in Outpatients |
title_sort | self-collected oral fluid saliva is insensitive compared with nasal-oropharyngeal swabs in the detection of severe acute respiratory syndrome coronavirus 2 in outpatients |
topic | Major Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7798743/ https://www.ncbi.nlm.nih.gov/pubmed/33604399 http://dx.doi.org/10.1093/ofid/ofaa648 |
work_keys_str_mv | AT manabeyukaric selfcollectedoralfluidsalivaisinsensitivecomparedwithnasaloropharyngealswabsinthedetectionofsevereacuterespiratorysyndromecoronavirus2inoutpatients AT reulandcarolyn selfcollectedoralfluidsalivaisinsensitivecomparedwithnasaloropharyngealswabsinthedetectionofsevereacuterespiratorysyndromecoronavirus2inoutpatients AT yutong selfcollectedoralfluidsalivaisinsensitivecomparedwithnasaloropharyngealswabsinthedetectionofsevereacuterespiratorysyndromecoronavirus2inoutpatients AT azamfireirazvan selfcollectedoralfluidsalivaisinsensitivecomparedwithnasaloropharyngealswabsinthedetectionofsevereacuterespiratorysyndromecoronavirus2inoutpatients AT hardickjustinp selfcollectedoralfluidsalivaisinsensitivecomparedwithnasaloropharyngealswabsinthedetectionofsevereacuterespiratorysyndromecoronavirus2inoutpatients AT churchtaylor selfcollectedoralfluidsalivaisinsensitivecomparedwithnasaloropharyngealswabsinthedetectionofsevereacuterespiratorysyndromecoronavirus2inoutpatients AT browndianem selfcollectedoralfluidsalivaisinsensitivecomparedwithnasaloropharyngealswabsinthedetectionofsevereacuterespiratorysyndromecoronavirus2inoutpatients AT sewelltheliot selfcollectedoralfluidsalivaisinsensitivecomparedwithnasaloropharyngealswabsinthedetectionofsevereacuterespiratorysyndromecoronavirus2inoutpatients AT antarannuka selfcollectedoralfluidsalivaisinsensitivecomparedwithnasaloropharyngealswabsinthedetectionofsevereacuterespiratorysyndromecoronavirus2inoutpatients AT blairpaulw selfcollectedoralfluidsalivaisinsensitivecomparedwithnasaloropharyngealswabsinthedetectionofsevereacuterespiratorysyndromecoronavirus2inoutpatients AT heaneychrisd selfcollectedoralfluidsalivaisinsensitivecomparedwithnasaloropharyngealswabsinthedetectionofsevereacuterespiratorysyndromecoronavirus2inoutpatients AT pekoszandrew selfcollectedoralfluidsalivaisinsensitivecomparedwithnasaloropharyngealswabsinthedetectionofsevereacuterespiratorysyndromecoronavirus2inoutpatients AT thomasdavidl selfcollectedoralfluidsalivaisinsensitivecomparedwithnasaloropharyngealswabsinthedetectionofsevereacuterespiratorysyndromecoronavirus2inoutpatients AT selfcollectedoralfluidsalivaisinsensitivecomparedwithnasaloropharyngealswabsinthedetectionofsevereacuterespiratorysyndromecoronavirus2inoutpatients |