Balanced steady-state free precession MRCP is a robust alternative to respiration-navigated 3D turbo-spin-echo MRCP

BACKGROUND: Despite synchronization to respiration, respiration-navigated (RN) 3D turbo-spin-echo MRCP is limited by susceptibility to motion artifacts. The aim of this study was to assess the quality of pancreaticobiliary duct visualization of a non-RN MRCP alternative based on balanced steady-stat...

Descripción completa

Detalles Bibliográficos
Autores principales: Hasse, Felix Christian, Selmi, Buket, Albusaidi, Hamed, Mokry, Theresa, Mayer, Philipp, Rupp, Christian, Kauczor, Hans-Ulrich, Weber, Tim Frederik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7802244/
https://www.ncbi.nlm.nih.gov/pubmed/33430780
http://dx.doi.org/10.1186/s12880-020-00532-w
Descripción
Sumario:BACKGROUND: Despite synchronization to respiration, respiration-navigated (RN) 3D turbo-spin-echo MRCP is limited by susceptibility to motion artifacts. The aim of this study was to assess the quality of pancreaticobiliary duct visualization of a non-RN MRCP alternative based on balanced steady-state free precession imaging (BSSFP) with overlapping slices compared with RN-MRCP. METHODS: This is a retrospective study on 50 patients without pancreaticobiliary duct disease receiving MRCP at 1.5 T. We performed an intraindividual comparison of coronal RN-MRCP with combined coronal and transverse BSSFP-MRCP. Image quality was scored by 3 readers for 6 pancreaticobiliary duct segments (3 pancreatic, 3 biliary) using a 6-point scale. A segment score of 3 or lower as assessed by at least 2 of 3 readers was defined as insufficient segment visualization. Nonparametric tests and interrater reliability testing were used for statistical analysis. RESULTS: Overall duct visualization averaged over all readers was scored with 4.5 ± 1.1 for RN-MRCP (pancreatic, 4.1 ± 0.5; biliary, 5.0 ± 0.4) and 4.9 ± 0.9 for combined coronal and transverse BSSFP-MRCP (pancreatic, 4.6 ± 0.6; biliary, 5.1 ± 0.6), respectively (p < 0.001). The number of segments visualized insufficiently was 81/300 for RN-MRCP and 43/300 for BSSFP-MRCP (p < 0.001). Segments visualized insufficiently only in RN-MRCP had a mean score of 4.4 ± 0.8 in BSSFP-MRCP. Overall interrater agreement on superiority of BSSFP-MRCP segment scores over corresponding RN-MRCP was 0.70. Mean acquisition time was 98% longer for RN-MRCP (198.0 ± 98.7 s) than for combined coronal and transverse BSSFP-MRCP (100.2 ± 0.4 s). CONCLUSIONS: Non-RN BSSFP-MRCP with overlapping slices is a fast alternative to RN-MRCP, frequently providing sufficient duct visualization when RN-MRCP fails.