Cargando…

Repeatability of Vascular Density Measurement of the Three Retinal Plexus Layers Using OCT Angiography in Pathologic Eyes (OCTA Vascular Density Repeatability of Three Plexus Layers)

PURPOSE: Although commercial optical coherence tomography angiography (OCTA) machines quantitate retinal vascular density (VD) by dividing the vasculature into superficial and deep capillary plexus (SCP, DCP), histology reveals three distinct plexus layers. This study tested the hypothesis that the...

Descripción completa

Detalles Bibliográficos
Autores principales: Mukkamala, Lekha, Nguyen, Michael, Chang, Melinda, Park, Susanna S
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7802913/
https://www.ncbi.nlm.nih.gov/pubmed/33447014
http://dx.doi.org/10.2147/OPTH.S284872
_version_ 1783635837913661440
author Mukkamala, Lekha
Nguyen, Michael
Chang, Melinda
Park, Susanna S
author_facet Mukkamala, Lekha
Nguyen, Michael
Chang, Melinda
Park, Susanna S
author_sort Mukkamala, Lekha
collection PubMed
description PURPOSE: Although commercial optical coherence tomography angiography (OCTA) machines quantitate retinal vascular density (VD) by dividing the vasculature into superficial and deep capillary plexus (SCP, DCP), histology reveals three distinct plexus layers. This study tested the hypothesis that the VD measurement of three distinct retinal plexus layers obtained using custom segmentation has high repeatability comparable to that of automatically segmented SCP and DCP layers. MATERIALS AND METHODS: Forty-four participants (86 eyes) were enrolled – 54 eyes with retinal vasculopathy and 25 eyes with macular edema. Macular OCTA images (3x3 mm and 6x6 mm) were obtained twice within 30 minutes by the same personnel using the same instrument (AngioVue, Optovue, version 2018.0.0.18). The intraclass correlation coefficient (ICC) was calculated to access repeatability. RESULTS: The repeatability of VD for SCP and DCP was good-to-moderate (ICC=0.65–0.85) and minimally affected by image quality, retinal vasculopathy, or macular edema. The repeatability of the VD of the custom-segmented intermediate and deep plexus layers (cICP and cDCP) was poor/moderate (ICC=0.40–0.74) but better in the subset without macular edema using 3x3 mm scans with good images quality (ICC=0.58–0.93). Repeatability of cICP and cDCP VD measurement for 6x6 mm scans was poor (ICC≤0.5) in eyes with retinal vasculopathy and/or macular edema. CONCLUSION: Although repeatability of the VD measurement is high for the automatically segmented SCP and DCP, repeatability of VD is poor for the cICP and cDCP using larger scans in eyes with retinal vasculopathy and/or macular edema.
format Online
Article
Text
id pubmed-7802913
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-78029132021-01-13 Repeatability of Vascular Density Measurement of the Three Retinal Plexus Layers Using OCT Angiography in Pathologic Eyes (OCTA Vascular Density Repeatability of Three Plexus Layers) Mukkamala, Lekha Nguyen, Michael Chang, Melinda Park, Susanna S Clin Ophthalmol Original Research PURPOSE: Although commercial optical coherence tomography angiography (OCTA) machines quantitate retinal vascular density (VD) by dividing the vasculature into superficial and deep capillary plexus (SCP, DCP), histology reveals three distinct plexus layers. This study tested the hypothesis that the VD measurement of three distinct retinal plexus layers obtained using custom segmentation has high repeatability comparable to that of automatically segmented SCP and DCP layers. MATERIALS AND METHODS: Forty-four participants (86 eyes) were enrolled – 54 eyes with retinal vasculopathy and 25 eyes with macular edema. Macular OCTA images (3x3 mm and 6x6 mm) were obtained twice within 30 minutes by the same personnel using the same instrument (AngioVue, Optovue, version 2018.0.0.18). The intraclass correlation coefficient (ICC) was calculated to access repeatability. RESULTS: The repeatability of VD for SCP and DCP was good-to-moderate (ICC=0.65–0.85) and minimally affected by image quality, retinal vasculopathy, or macular edema. The repeatability of the VD of the custom-segmented intermediate and deep plexus layers (cICP and cDCP) was poor/moderate (ICC=0.40–0.74) but better in the subset without macular edema using 3x3 mm scans with good images quality (ICC=0.58–0.93). Repeatability of cICP and cDCP VD measurement for 6x6 mm scans was poor (ICC≤0.5) in eyes with retinal vasculopathy and/or macular edema. CONCLUSION: Although repeatability of the VD measurement is high for the automatically segmented SCP and DCP, repeatability of VD is poor for the cICP and cDCP using larger scans in eyes with retinal vasculopathy and/or macular edema. Dove 2021-01-08 /pmc/articles/PMC7802913/ /pubmed/33447014 http://dx.doi.org/10.2147/OPTH.S284872 Text en © 2021 Mukkamala et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Mukkamala, Lekha
Nguyen, Michael
Chang, Melinda
Park, Susanna S
Repeatability of Vascular Density Measurement of the Three Retinal Plexus Layers Using OCT Angiography in Pathologic Eyes (OCTA Vascular Density Repeatability of Three Plexus Layers)
title Repeatability of Vascular Density Measurement of the Three Retinal Plexus Layers Using OCT Angiography in Pathologic Eyes (OCTA Vascular Density Repeatability of Three Plexus Layers)
title_full Repeatability of Vascular Density Measurement of the Three Retinal Plexus Layers Using OCT Angiography in Pathologic Eyes (OCTA Vascular Density Repeatability of Three Plexus Layers)
title_fullStr Repeatability of Vascular Density Measurement of the Three Retinal Plexus Layers Using OCT Angiography in Pathologic Eyes (OCTA Vascular Density Repeatability of Three Plexus Layers)
title_full_unstemmed Repeatability of Vascular Density Measurement of the Three Retinal Plexus Layers Using OCT Angiography in Pathologic Eyes (OCTA Vascular Density Repeatability of Three Plexus Layers)
title_short Repeatability of Vascular Density Measurement of the Three Retinal Plexus Layers Using OCT Angiography in Pathologic Eyes (OCTA Vascular Density Repeatability of Three Plexus Layers)
title_sort repeatability of vascular density measurement of the three retinal plexus layers using oct angiography in pathologic eyes (octa vascular density repeatability of three plexus layers)
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7802913/
https://www.ncbi.nlm.nih.gov/pubmed/33447014
http://dx.doi.org/10.2147/OPTH.S284872
work_keys_str_mv AT mukkamalalekha repeatabilityofvasculardensitymeasurementofthethreeretinalplexuslayersusingoctangiographyinpathologiceyesoctavasculardensityrepeatabilityofthreeplexuslayers
AT nguyenmichael repeatabilityofvasculardensitymeasurementofthethreeretinalplexuslayersusingoctangiographyinpathologiceyesoctavasculardensityrepeatabilityofthreeplexuslayers
AT changmelinda repeatabilityofvasculardensitymeasurementofthethreeretinalplexuslayersusingoctangiographyinpathologiceyesoctavasculardensityrepeatabilityofthreeplexuslayers
AT parksusannas repeatabilityofvasculardensitymeasurementofthethreeretinalplexuslayersusingoctangiographyinpathologiceyesoctavasculardensityrepeatabilityofthreeplexuslayers