Diagnostic Performance of a Novel Noninvasive Workup in the Setting of Dry Eye Disease

PURPOSE: To evaluate the diagnostic performance of a novel noninvasive automated workup employed for the diagnosis of dry eye disease (DED). METHODS: One hundred patients with mild to moderate DED and 100 matched control subjects were enrolled in this cross-sectional study. Ocular surface examinatio...

Descripción completa

Detalles Bibliográficos
Autores principales: Vigo, Luca, Pellegrini, Marco, Bernabei, Federico, Carones, Francesco, Scorcia, Vincenzo, Giannaccare, Giuseppe
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7803097/
https://www.ncbi.nlm.nih.gov/pubmed/33489333
http://dx.doi.org/10.1155/2020/5804123
_version_ 1783635879579877376
author Vigo, Luca
Pellegrini, Marco
Bernabei, Federico
Carones, Francesco
Scorcia, Vincenzo
Giannaccare, Giuseppe
author_facet Vigo, Luca
Pellegrini, Marco
Bernabei, Federico
Carones, Francesco
Scorcia, Vincenzo
Giannaccare, Giuseppe
author_sort Vigo, Luca
collection PubMed
description PURPOSE: To evaluate the diagnostic performance of a novel noninvasive automated workup employed for the diagnosis of dry eye disease (DED). METHODS: One hundred patients with mild to moderate DED and 100 matched control subjects were enrolled in this cross-sectional study. Ocular surface examinations were carried out by means of IDRA Plus (SBM Sistemi, Turin, Italy), which allows the automated evaluation of noninvasive breakup time (NIBUT), lipid layer thickness (LLT), tear meniscus height (TMH), infrared meibography for the measurement of meibomian gland loss (MGL), and blinking analysis. Continuous variables were compared between patients with DED and controls by using the Mann–Whitney U test. The area under the curve (AUC) of receiver operating characteristic curves was calculated. The correlations between ocular surface parameters were evaluated with Pearson correlation analysis. RESULTS: Patients with DED showed significantly lower values of NIBUT, LLT, and TMH compared to controls (6.9 ± 2.5 vs 10.4 ± 2.4 s, P < 0.001; 64.6 ± 20.3 vs 73.4 ± 21.9 nm, P = 0.003; 0.231 ± 0.115 vs 0.289 ± 0.164, P = 0.012, respectively). Conversely, no significant differences were observed for MGL and blinking analysis (both P > 0.05). NIBUT had the highest diagnostic power (AUC = 0.841, sensitivity = 0.89, and specificity = 0.69), followed by LLT (AUC = 0.621, sensitivity = 0.89, and specificity = 0.55), TMH (AUC = 0.606, sensitivity = 0.57, and specificity = 0.63), blink analysis (AUC = 0.533, sensitivity = 0.48, and specificity = 0.59), and MGL (AUC = 0.531, sensitivity = 0.54, and specificity = 0.48). In patients with DED, NIBUT showed a significant correlation with TMH (R = 0.347, P = 0.002) and blinking analysis (R = 0.356, P < 0.001), while blinking analysis was negatively correlated with MGL (R = −0.315, P = 0.008). CONCLUSIONS: The automated noninvasive workup validated in this study may be a useful tool for reaching a noninvasive diagnosis of DED with a good performance, especially for NIBUT.
format Online
Article
Text
id pubmed-7803097
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-78030972021-01-22 Diagnostic Performance of a Novel Noninvasive Workup in the Setting of Dry Eye Disease Vigo, Luca Pellegrini, Marco Bernabei, Federico Carones, Francesco Scorcia, Vincenzo Giannaccare, Giuseppe J Ophthalmol Research Article PURPOSE: To evaluate the diagnostic performance of a novel noninvasive automated workup employed for the diagnosis of dry eye disease (DED). METHODS: One hundred patients with mild to moderate DED and 100 matched control subjects were enrolled in this cross-sectional study. Ocular surface examinations were carried out by means of IDRA Plus (SBM Sistemi, Turin, Italy), which allows the automated evaluation of noninvasive breakup time (NIBUT), lipid layer thickness (LLT), tear meniscus height (TMH), infrared meibography for the measurement of meibomian gland loss (MGL), and blinking analysis. Continuous variables were compared between patients with DED and controls by using the Mann–Whitney U test. The area under the curve (AUC) of receiver operating characteristic curves was calculated. The correlations between ocular surface parameters were evaluated with Pearson correlation analysis. RESULTS: Patients with DED showed significantly lower values of NIBUT, LLT, and TMH compared to controls (6.9 ± 2.5 vs 10.4 ± 2.4 s, P < 0.001; 64.6 ± 20.3 vs 73.4 ± 21.9 nm, P = 0.003; 0.231 ± 0.115 vs 0.289 ± 0.164, P = 0.012, respectively). Conversely, no significant differences were observed for MGL and blinking analysis (both P > 0.05). NIBUT had the highest diagnostic power (AUC = 0.841, sensitivity = 0.89, and specificity = 0.69), followed by LLT (AUC = 0.621, sensitivity = 0.89, and specificity = 0.55), TMH (AUC = 0.606, sensitivity = 0.57, and specificity = 0.63), blink analysis (AUC = 0.533, sensitivity = 0.48, and specificity = 0.59), and MGL (AUC = 0.531, sensitivity = 0.54, and specificity = 0.48). In patients with DED, NIBUT showed a significant correlation with TMH (R = 0.347, P = 0.002) and blinking analysis (R = 0.356, P < 0.001), while blinking analysis was negatively correlated with MGL (R = −0.315, P = 0.008). CONCLUSIONS: The automated noninvasive workup validated in this study may be a useful tool for reaching a noninvasive diagnosis of DED with a good performance, especially for NIBUT. Hindawi 2020-12-11 /pmc/articles/PMC7803097/ /pubmed/33489333 http://dx.doi.org/10.1155/2020/5804123 Text en Copyright © 2020 Luca Vigo et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Vigo, Luca
Pellegrini, Marco
Bernabei, Federico
Carones, Francesco
Scorcia, Vincenzo
Giannaccare, Giuseppe
Diagnostic Performance of a Novel Noninvasive Workup in the Setting of Dry Eye Disease
title Diagnostic Performance of a Novel Noninvasive Workup in the Setting of Dry Eye Disease
title_full Diagnostic Performance of a Novel Noninvasive Workup in the Setting of Dry Eye Disease
title_fullStr Diagnostic Performance of a Novel Noninvasive Workup in the Setting of Dry Eye Disease
title_full_unstemmed Diagnostic Performance of a Novel Noninvasive Workup in the Setting of Dry Eye Disease
title_short Diagnostic Performance of a Novel Noninvasive Workup in the Setting of Dry Eye Disease
title_sort diagnostic performance of a novel noninvasive workup in the setting of dry eye disease
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7803097/
https://www.ncbi.nlm.nih.gov/pubmed/33489333
http://dx.doi.org/10.1155/2020/5804123
work_keys_str_mv AT vigoluca diagnosticperformanceofanovelnoninvasiveworkupinthesettingofdryeyedisease
AT pellegrinimarco diagnosticperformanceofanovelnoninvasiveworkupinthesettingofdryeyedisease
AT bernabeifederico diagnosticperformanceofanovelnoninvasiveworkupinthesettingofdryeyedisease
AT caronesfrancesco diagnosticperformanceofanovelnoninvasiveworkupinthesettingofdryeyedisease
AT scorciavincenzo diagnosticperformanceofanovelnoninvasiveworkupinthesettingofdryeyedisease
AT giannaccaregiuseppe diagnosticperformanceofanovelnoninvasiveworkupinthesettingofdryeyedisease