Cargando…

Measuring particle concentration of multimodal synthetic reference materials and extracellular vesicles with orthogonal techniques: Who is up to the challenge?

The measurement of physicochemical properties of polydisperse complex biological samples, for example, extracellular vesicles, is critical to assess their quality, for example, resulting from their production and isolation methods. The community is gradually becoming aware of the need to combine mul...

Descripción completa

Detalles Bibliográficos
Autores principales: Vogel, Robert, Savage, John, Muzard, Julien, Camera, Giacomo Della, Vella, Gabriele, Law, Alice, Marchioni, Marianne, Mehn, Dora, Geiss, Otmar, Peacock, Ben, Aubert, Dimitri, Calzolai, Luigi, Caputo, Fanny, Prina‐Mello, Adriele
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7804049/
https://www.ncbi.nlm.nih.gov/pubmed/33473263
http://dx.doi.org/10.1002/jev2.12052
_version_ 1783636078016593920
author Vogel, Robert
Savage, John
Muzard, Julien
Camera, Giacomo Della
Vella, Gabriele
Law, Alice
Marchioni, Marianne
Mehn, Dora
Geiss, Otmar
Peacock, Ben
Aubert, Dimitri
Calzolai, Luigi
Caputo, Fanny
Prina‐Mello, Adriele
author_facet Vogel, Robert
Savage, John
Muzard, Julien
Camera, Giacomo Della
Vella, Gabriele
Law, Alice
Marchioni, Marianne
Mehn, Dora
Geiss, Otmar
Peacock, Ben
Aubert, Dimitri
Calzolai, Luigi
Caputo, Fanny
Prina‐Mello, Adriele
author_sort Vogel, Robert
collection PubMed
description The measurement of physicochemical properties of polydisperse complex biological samples, for example, extracellular vesicles, is critical to assess their quality, for example, resulting from their production and isolation methods. The community is gradually becoming aware of the need to combine multiple orthogonal techniques to perform a robust characterization of complex biological samples. Three pillars of critical quality attribute characterization of EVs are sizing, concentration measurement and phenotyping. The repeatable measurement of vesicle concentration is one of the key‐challenges that requires further efforts, in order to obtain comparable results by using different techniques and assure reproducibility. In this study, the performance of measuring the concentration of particles in the size range of 50–300 nm with complementary techniques is thoroughly investigated in a step‐by step approach of incremental complexity. The six applied techniques include multi‐angle dynamic light scattering (MADLS), asymmetric flow field flow fractionation coupled with multi‐angle light scattering (AF4‐MALS), centrifugal liquid sedimentation (CLS), nanoparticle tracking analysis (NTA), tunable resistive pulse sensing (TRPS), and high‐sensitivity nano flow cytometry (nFCM). To achieve comparability, monomodal samples and complex polystyrene mixtures were used as particles of metrological interest, in order to check the suitability of each technique in the size and concentration range of interest, and to develop reliable post‐processing data protocols for the analysis. Subsequent complexity was introduced by testing liposomes as validation of the developed approaches with a known sample of physicochemical properties closer to EVs. Finally, the vesicles in EV containing plasma samples were analysed with all the tested techniques. The results presented here aim to shed some light into the requirements for the complex characterization of biological samples, as this is a critical need for quality assurance by the EV and regulatory community. Such efforts go with the view to contribute to both, set‐up reproducible and reliable characterization protocols, and comply with the Minimal Information for Studies of Extracellular Vesicles (MISEV) requirements.
format Online
Article
Text
id pubmed-7804049
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-78040492021-01-19 Measuring particle concentration of multimodal synthetic reference materials and extracellular vesicles with orthogonal techniques: Who is up to the challenge? Vogel, Robert Savage, John Muzard, Julien Camera, Giacomo Della Vella, Gabriele Law, Alice Marchioni, Marianne Mehn, Dora Geiss, Otmar Peacock, Ben Aubert, Dimitri Calzolai, Luigi Caputo, Fanny Prina‐Mello, Adriele J Extracell Vesicles Research Articles The measurement of physicochemical properties of polydisperse complex biological samples, for example, extracellular vesicles, is critical to assess their quality, for example, resulting from their production and isolation methods. The community is gradually becoming aware of the need to combine multiple orthogonal techniques to perform a robust characterization of complex biological samples. Three pillars of critical quality attribute characterization of EVs are sizing, concentration measurement and phenotyping. The repeatable measurement of vesicle concentration is one of the key‐challenges that requires further efforts, in order to obtain comparable results by using different techniques and assure reproducibility. In this study, the performance of measuring the concentration of particles in the size range of 50–300 nm with complementary techniques is thoroughly investigated in a step‐by step approach of incremental complexity. The six applied techniques include multi‐angle dynamic light scattering (MADLS), asymmetric flow field flow fractionation coupled with multi‐angle light scattering (AF4‐MALS), centrifugal liquid sedimentation (CLS), nanoparticle tracking analysis (NTA), tunable resistive pulse sensing (TRPS), and high‐sensitivity nano flow cytometry (nFCM). To achieve comparability, monomodal samples and complex polystyrene mixtures were used as particles of metrological interest, in order to check the suitability of each technique in the size and concentration range of interest, and to develop reliable post‐processing data protocols for the analysis. Subsequent complexity was introduced by testing liposomes as validation of the developed approaches with a known sample of physicochemical properties closer to EVs. Finally, the vesicles in EV containing plasma samples were analysed with all the tested techniques. The results presented here aim to shed some light into the requirements for the complex characterization of biological samples, as this is a critical need for quality assurance by the EV and regulatory community. Such efforts go with the view to contribute to both, set‐up reproducible and reliable characterization protocols, and comply with the Minimal Information for Studies of Extracellular Vesicles (MISEV) requirements. John Wiley and Sons Inc. 2021-01-12 2021-01 /pmc/articles/PMC7804049/ /pubmed/33473263 http://dx.doi.org/10.1002/jev2.12052 Text en © 2021 The Authors. Journal of Extracellular Vesicles published by Wiley Periodicals, LLC on behalf of the International Society for Extracellular Vesicles https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Articles
Vogel, Robert
Savage, John
Muzard, Julien
Camera, Giacomo Della
Vella, Gabriele
Law, Alice
Marchioni, Marianne
Mehn, Dora
Geiss, Otmar
Peacock, Ben
Aubert, Dimitri
Calzolai, Luigi
Caputo, Fanny
Prina‐Mello, Adriele
Measuring particle concentration of multimodal synthetic reference materials and extracellular vesicles with orthogonal techniques: Who is up to the challenge?
title Measuring particle concentration of multimodal synthetic reference materials and extracellular vesicles with orthogonal techniques: Who is up to the challenge?
title_full Measuring particle concentration of multimodal synthetic reference materials and extracellular vesicles with orthogonal techniques: Who is up to the challenge?
title_fullStr Measuring particle concentration of multimodal synthetic reference materials and extracellular vesicles with orthogonal techniques: Who is up to the challenge?
title_full_unstemmed Measuring particle concentration of multimodal synthetic reference materials and extracellular vesicles with orthogonal techniques: Who is up to the challenge?
title_short Measuring particle concentration of multimodal synthetic reference materials and extracellular vesicles with orthogonal techniques: Who is up to the challenge?
title_sort measuring particle concentration of multimodal synthetic reference materials and extracellular vesicles with orthogonal techniques: who is up to the challenge?
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7804049/
https://www.ncbi.nlm.nih.gov/pubmed/33473263
http://dx.doi.org/10.1002/jev2.12052
work_keys_str_mv AT vogelrobert measuringparticleconcentrationofmultimodalsyntheticreferencematerialsandextracellularvesicleswithorthogonaltechniqueswhoisuptothechallenge
AT savagejohn measuringparticleconcentrationofmultimodalsyntheticreferencematerialsandextracellularvesicleswithorthogonaltechniqueswhoisuptothechallenge
AT muzardjulien measuringparticleconcentrationofmultimodalsyntheticreferencematerialsandextracellularvesicleswithorthogonaltechniqueswhoisuptothechallenge
AT cameragiacomodella measuringparticleconcentrationofmultimodalsyntheticreferencematerialsandextracellularvesicleswithorthogonaltechniqueswhoisuptothechallenge
AT vellagabriele measuringparticleconcentrationofmultimodalsyntheticreferencematerialsandextracellularvesicleswithorthogonaltechniqueswhoisuptothechallenge
AT lawalice measuringparticleconcentrationofmultimodalsyntheticreferencematerialsandextracellularvesicleswithorthogonaltechniqueswhoisuptothechallenge
AT marchionimarianne measuringparticleconcentrationofmultimodalsyntheticreferencematerialsandextracellularvesicleswithorthogonaltechniqueswhoisuptothechallenge
AT mehndora measuringparticleconcentrationofmultimodalsyntheticreferencematerialsandextracellularvesicleswithorthogonaltechniqueswhoisuptothechallenge
AT geissotmar measuringparticleconcentrationofmultimodalsyntheticreferencematerialsandextracellularvesicleswithorthogonaltechniqueswhoisuptothechallenge
AT peacockben measuringparticleconcentrationofmultimodalsyntheticreferencematerialsandextracellularvesicleswithorthogonaltechniqueswhoisuptothechallenge
AT aubertdimitri measuringparticleconcentrationofmultimodalsyntheticreferencematerialsandextracellularvesicleswithorthogonaltechniqueswhoisuptothechallenge
AT calzolailuigi measuringparticleconcentrationofmultimodalsyntheticreferencematerialsandextracellularvesicleswithorthogonaltechniqueswhoisuptothechallenge
AT caputofanny measuringparticleconcentrationofmultimodalsyntheticreferencematerialsandextracellularvesicleswithorthogonaltechniqueswhoisuptothechallenge
AT prinamelloadriele measuringparticleconcentrationofmultimodalsyntheticreferencematerialsandextracellularvesicleswithorthogonaltechniqueswhoisuptothechallenge