Cargando…
Synchronized Tactile Stimulation on Upper Limbs Using a Wearable Robot for Gait Assistance in Patients With Parkinson's Disease
This study aimed to investigate whether using a wearable robot applying interactive rhythmic stimulation on the upper limbs of patients with Parkinson's disease (PD) could affect their gait. The wearable robot presented tactile stimuli on the patients' upper limbs, which was mutually synch...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7806086/ https://www.ncbi.nlm.nih.gov/pubmed/33501179 http://dx.doi.org/10.3389/frobt.2020.00010 |
_version_ | 1783636453252661248 |
---|---|
author | Kishi, Takayuki Ogata, Taiki Ora, Hiroki Shigeyama, Ryo Nakayama, Masayuki Seki, Masatoshi Orimo, Satoshi Miyake, Yoshihiro |
author_facet | Kishi, Takayuki Ogata, Taiki Ora, Hiroki Shigeyama, Ryo Nakayama, Masayuki Seki, Masatoshi Orimo, Satoshi Miyake, Yoshihiro |
author_sort | Kishi, Takayuki |
collection | PubMed |
description | This study aimed to investigate whether using a wearable robot applying interactive rhythmic stimulation on the upper limbs of patients with Parkinson's disease (PD) could affect their gait. The wearable robot presented tactile stimuli on the patients' upper limbs, which was mutually synchronized with the swing of their upper limbs. We conducted an evaluation experiment with PD patients (n = 30, Modified Hoehn-Yahr = 1–3, on-state) to investigate the assistance effect by the robot and the immediate after-effect of intervention. The participants were instructed to walk 30 m under four different conditions: (1) not wearing the robot before the intervention (Pre-condition), (2) wearing the robot without the rhythm assistance (RwoA condition), (3) wearing the robot with rhythm assistance (RwA condition), and (4) not wearing the robot immediately after the intervention (Post-condition). These conditions were conducted in this order over a single day. The third condition was performed three times and the others, once. The arm swing amplitude, stride length, and velocity were increased in the RwA condition compared to the RwoA condition. The coefficient of variance (CV) of the stride duration was decreased in the RwA condition compared to the RwoA condition. These results revealed that the assistance by the robot increased the gait performance of PD patients. In addition, the stride length and velocity were increased and the stride duration CV was decreased in the Post-condition compared to the Pre-condition. These results show that the effect of robot assistance on the patient's gait remained immediately after the intervention. These findings suggest that synchronized rhythmic stimulation on the upper limbs could influence the gait of PD patients and that the robot may assist with gait rehabilitation in these patients. |
format | Online Article Text |
id | pubmed-7806086 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-78060862021-01-25 Synchronized Tactile Stimulation on Upper Limbs Using a Wearable Robot for Gait Assistance in Patients With Parkinson's Disease Kishi, Takayuki Ogata, Taiki Ora, Hiroki Shigeyama, Ryo Nakayama, Masayuki Seki, Masatoshi Orimo, Satoshi Miyake, Yoshihiro Front Robot AI Robotics and AI This study aimed to investigate whether using a wearable robot applying interactive rhythmic stimulation on the upper limbs of patients with Parkinson's disease (PD) could affect their gait. The wearable robot presented tactile stimuli on the patients' upper limbs, which was mutually synchronized with the swing of their upper limbs. We conducted an evaluation experiment with PD patients (n = 30, Modified Hoehn-Yahr = 1–3, on-state) to investigate the assistance effect by the robot and the immediate after-effect of intervention. The participants were instructed to walk 30 m under four different conditions: (1) not wearing the robot before the intervention (Pre-condition), (2) wearing the robot without the rhythm assistance (RwoA condition), (3) wearing the robot with rhythm assistance (RwA condition), and (4) not wearing the robot immediately after the intervention (Post-condition). These conditions were conducted in this order over a single day. The third condition was performed three times and the others, once. The arm swing amplitude, stride length, and velocity were increased in the RwA condition compared to the RwoA condition. The coefficient of variance (CV) of the stride duration was decreased in the RwA condition compared to the RwoA condition. These results revealed that the assistance by the robot increased the gait performance of PD patients. In addition, the stride length and velocity were increased and the stride duration CV was decreased in the Post-condition compared to the Pre-condition. These results show that the effect of robot assistance on the patient's gait remained immediately after the intervention. These findings suggest that synchronized rhythmic stimulation on the upper limbs could influence the gait of PD patients and that the robot may assist with gait rehabilitation in these patients. Frontiers Media S.A. 2020-02-27 /pmc/articles/PMC7806086/ /pubmed/33501179 http://dx.doi.org/10.3389/frobt.2020.00010 Text en Copyright © 2020 Kishi, Ogata, Ora, Shigeyama, Nakayama, Seki, Orimo and Miyake. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Robotics and AI Kishi, Takayuki Ogata, Taiki Ora, Hiroki Shigeyama, Ryo Nakayama, Masayuki Seki, Masatoshi Orimo, Satoshi Miyake, Yoshihiro Synchronized Tactile Stimulation on Upper Limbs Using a Wearable Robot for Gait Assistance in Patients With Parkinson's Disease |
title | Synchronized Tactile Stimulation on Upper Limbs Using a Wearable Robot for Gait Assistance in Patients With Parkinson's Disease |
title_full | Synchronized Tactile Stimulation on Upper Limbs Using a Wearable Robot for Gait Assistance in Patients With Parkinson's Disease |
title_fullStr | Synchronized Tactile Stimulation on Upper Limbs Using a Wearable Robot for Gait Assistance in Patients With Parkinson's Disease |
title_full_unstemmed | Synchronized Tactile Stimulation on Upper Limbs Using a Wearable Robot for Gait Assistance in Patients With Parkinson's Disease |
title_short | Synchronized Tactile Stimulation on Upper Limbs Using a Wearable Robot for Gait Assistance in Patients With Parkinson's Disease |
title_sort | synchronized tactile stimulation on upper limbs using a wearable robot for gait assistance in patients with parkinson's disease |
topic | Robotics and AI |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7806086/ https://www.ncbi.nlm.nih.gov/pubmed/33501179 http://dx.doi.org/10.3389/frobt.2020.00010 |
work_keys_str_mv | AT kishitakayuki synchronizedtactilestimulationonupperlimbsusingawearablerobotforgaitassistanceinpatientswithparkinsonsdisease AT ogatataiki synchronizedtactilestimulationonupperlimbsusingawearablerobotforgaitassistanceinpatientswithparkinsonsdisease AT orahiroki synchronizedtactilestimulationonupperlimbsusingawearablerobotforgaitassistanceinpatientswithparkinsonsdisease AT shigeyamaryo synchronizedtactilestimulationonupperlimbsusingawearablerobotforgaitassistanceinpatientswithparkinsonsdisease AT nakayamamasayuki synchronizedtactilestimulationonupperlimbsusingawearablerobotforgaitassistanceinpatientswithparkinsonsdisease AT sekimasatoshi synchronizedtactilestimulationonupperlimbsusingawearablerobotforgaitassistanceinpatientswithparkinsonsdisease AT orimosatoshi synchronizedtactilestimulationonupperlimbsusingawearablerobotforgaitassistanceinpatientswithparkinsonsdisease AT miyakeyoshihiro synchronizedtactilestimulationonupperlimbsusingawearablerobotforgaitassistanceinpatientswithparkinsonsdisease |