Cargando…

A method to alleviate false-positive results of the Elecsys HIV combi PT assay

To explore the effects of urea dissociation on reducing false-positive results of  the Elecsys HIV combi PT assay. A retrospective analysis was used to evaluate the false-positive rate of the Elecsys HIV combi PT assay. Six false-positive sera, six positive sera and six sera from patients with early...

Descripción completa

Detalles Bibliográficos
Autores principales: Lu, Xiaolan, Zhang, Minghong, Liu, Wen, Sheng, Nan, Du, Qin, Zhang, Maoxin, Guo, Xiaolan, Wang, Guangrong, Wang, Qiang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7807026/
https://www.ncbi.nlm.nih.gov/pubmed/33441741
http://dx.doi.org/10.1038/s41598-020-80047-0
_version_ 1783636656478224384
author Lu, Xiaolan
Zhang, Minghong
Liu, Wen
Sheng, Nan
Du, Qin
Zhang, Maoxin
Guo, Xiaolan
Wang, Guangrong
Wang, Qiang
author_facet Lu, Xiaolan
Zhang, Minghong
Liu, Wen
Sheng, Nan
Du, Qin
Zhang, Maoxin
Guo, Xiaolan
Wang, Guangrong
Wang, Qiang
author_sort Lu, Xiaolan
collection PubMed
description To explore the effects of urea dissociation on reducing false-positive results of  the Elecsys HIV combi PT assay. A retrospective analysis was used to evaluate the false-positive rate of the Elecsys HIV combi PT assay. Six false-positive sera, six positive sera and six sera from patients with early HIV infection were collected. Dissociation was performed using 1 mol/L, 2 mol/L, 4 mol/L, 6 mol/L, or 8 mol/L urea, and HIV screening assay were then detected to select the appropriate concentration of urea dissociation. Next, 55 false-positive sera and 15 sera from early HIV infection were used to verify the best concentration of urea to achieve dissociation. Retrospective analysis showed that the COI of the Elecsys HIV combi PT assay in false-positive sera ranged from 1.0 to 200.0, and approximately 97.01%(227/234) of false-positive sera were in the range of 1.0–15.0. The avidity index (AI) in positive and false-positive sera decreased as the urea dissociation concentration increased. When the dissociation concentration was 6 mol/L, the AI of false-positive serum was between 0.0234 and 0.2567, and the AI of early HIV infection sera was between 0.4325 and 0.5017. The difference in AI between false-positive and positive samples was significant. When negativity was defined as an AI of less than 0.3970, the sensitivity and specificity were 100.0% and 100.0%, respectively. Urea-mediated dissociation could significantly reduce the false-positive rate of the Elecsys HIV combi PT assay with a low COI. Our findings provided a reference for distinguishing positive and false-positive of the Elecsys HIV combi PT assay.
format Online
Article
Text
id pubmed-7807026
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-78070262021-01-14 A method to alleviate false-positive results of the Elecsys HIV combi PT assay Lu, Xiaolan Zhang, Minghong Liu, Wen Sheng, Nan Du, Qin Zhang, Maoxin Guo, Xiaolan Wang, Guangrong Wang, Qiang Sci Rep Article To explore the effects of urea dissociation on reducing false-positive results of  the Elecsys HIV combi PT assay. A retrospective analysis was used to evaluate the false-positive rate of the Elecsys HIV combi PT assay. Six false-positive sera, six positive sera and six sera from patients with early HIV infection were collected. Dissociation was performed using 1 mol/L, 2 mol/L, 4 mol/L, 6 mol/L, or 8 mol/L urea, and HIV screening assay were then detected to select the appropriate concentration of urea dissociation. Next, 55 false-positive sera and 15 sera from early HIV infection were used to verify the best concentration of urea to achieve dissociation. Retrospective analysis showed that the COI of the Elecsys HIV combi PT assay in false-positive sera ranged from 1.0 to 200.0, and approximately 97.01%(227/234) of false-positive sera were in the range of 1.0–15.0. The avidity index (AI) in positive and false-positive sera decreased as the urea dissociation concentration increased. When the dissociation concentration was 6 mol/L, the AI of false-positive serum was between 0.0234 and 0.2567, and the AI of early HIV infection sera was between 0.4325 and 0.5017. The difference in AI between false-positive and positive samples was significant. When negativity was defined as an AI of less than 0.3970, the sensitivity and specificity were 100.0% and 100.0%, respectively. Urea-mediated dissociation could significantly reduce the false-positive rate of the Elecsys HIV combi PT assay with a low COI. Our findings provided a reference for distinguishing positive and false-positive of the Elecsys HIV combi PT assay. Nature Publishing Group UK 2021-01-13 /pmc/articles/PMC7807026/ /pubmed/33441741 http://dx.doi.org/10.1038/s41598-020-80047-0 Text en © The Author(s) 2021 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Lu, Xiaolan
Zhang, Minghong
Liu, Wen
Sheng, Nan
Du, Qin
Zhang, Maoxin
Guo, Xiaolan
Wang, Guangrong
Wang, Qiang
A method to alleviate false-positive results of the Elecsys HIV combi PT assay
title A method to alleviate false-positive results of the Elecsys HIV combi PT assay
title_full A method to alleviate false-positive results of the Elecsys HIV combi PT assay
title_fullStr A method to alleviate false-positive results of the Elecsys HIV combi PT assay
title_full_unstemmed A method to alleviate false-positive results of the Elecsys HIV combi PT assay
title_short A method to alleviate false-positive results of the Elecsys HIV combi PT assay
title_sort method to alleviate false-positive results of the elecsys hiv combi pt assay
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7807026/
https://www.ncbi.nlm.nih.gov/pubmed/33441741
http://dx.doi.org/10.1038/s41598-020-80047-0
work_keys_str_mv AT luxiaolan amethodtoalleviatefalsepositiveresultsoftheelecsyshivcombiptassay
AT zhangminghong amethodtoalleviatefalsepositiveresultsoftheelecsyshivcombiptassay
AT liuwen amethodtoalleviatefalsepositiveresultsoftheelecsyshivcombiptassay
AT shengnan amethodtoalleviatefalsepositiveresultsoftheelecsyshivcombiptassay
AT duqin amethodtoalleviatefalsepositiveresultsoftheelecsyshivcombiptassay
AT zhangmaoxin amethodtoalleviatefalsepositiveresultsoftheelecsyshivcombiptassay
AT guoxiaolan amethodtoalleviatefalsepositiveresultsoftheelecsyshivcombiptassay
AT wangguangrong amethodtoalleviatefalsepositiveresultsoftheelecsyshivcombiptassay
AT wangqiang amethodtoalleviatefalsepositiveresultsoftheelecsyshivcombiptassay
AT luxiaolan methodtoalleviatefalsepositiveresultsoftheelecsyshivcombiptassay
AT zhangminghong methodtoalleviatefalsepositiveresultsoftheelecsyshivcombiptassay
AT liuwen methodtoalleviatefalsepositiveresultsoftheelecsyshivcombiptassay
AT shengnan methodtoalleviatefalsepositiveresultsoftheelecsyshivcombiptassay
AT duqin methodtoalleviatefalsepositiveresultsoftheelecsyshivcombiptassay
AT zhangmaoxin methodtoalleviatefalsepositiveresultsoftheelecsyshivcombiptassay
AT guoxiaolan methodtoalleviatefalsepositiveresultsoftheelecsyshivcombiptassay
AT wangguangrong methodtoalleviatefalsepositiveresultsoftheelecsyshivcombiptassay
AT wangqiang methodtoalleviatefalsepositiveresultsoftheelecsyshivcombiptassay