Diagnostic accuracy of a bovine specific electronic beta-hydroxybutyrate handheld meter in fresh blood and stored serum samples

This study aims to evaluate the diagnostic accuracy of the bovine specific beta-hydroxybutyrate (BHB) meter Nova Vet (NVET). We evaluated the accuracy and agreement of the NVET in fresh blood and thawed serum with the reference laboratory assay; and the repeatability, the interference by anticoagula...

Descripción completa

Detalles Bibliográficos
Autores principales: Rodriguez, Z., Caixeta, L.S., Cramer, G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7807146/
https://www.ncbi.nlm.nih.gov/pubmed/33490711
http://dx.doi.org/10.1016/j.vas.2020.100159
_version_ 1783636684670238720
author Rodriguez, Z.
Caixeta, L.S.
Cramer, G.
author_facet Rodriguez, Z.
Caixeta, L.S.
Cramer, G.
author_sort Rodriguez, Z.
collection PubMed
description This study aims to evaluate the diagnostic accuracy of the bovine specific beta-hydroxybutyrate (BHB) meter Nova Vet (NVET). We evaluated the accuracy and agreement of the NVET in fresh blood and thawed serum with the reference laboratory assay; and the repeatability, the interference by anticoagulants, and the optimum slope calibration factor. Individual blood samples were collected from 200 Holstein and crossbred cows between 3 and 14 days post-calving from 13 dairy herds in Minnesota. Using a laboratory assay with a cut point of 1.2 BHB mmol/L hyperketonemia prevalence was 10.6% (95% CI: 6.7, 15.8). The sensitivity of NVET in blood and serum was 100.0% while the specificity was 98.3 and 97.7% respectively. The agreement between NVET and the laboratory assay was the highest using blood samples (concordance correlation coefficient –CCC = 96.2, 95% CI: 95.0, 97.1. The coefficient of variation including within day (intra-meter), between- days, and -batches was 13.4% when testing blood samples. Minimal interference was observed with the use of anticoagulants (K-EDTA and Li-Heparin, CCC 0.90 and 0.93 respectively) in reference to whole blood without anticoagulant. The best calibration slope factor in serum was 1.0 (Youden's index: 0.98). Results suggest that the NVET device maintained a high accuracy and precision to quantified BHB concentration when applied in fresh blood and thawed serum under field conditions using the default calibration slope (1.0), and with minimal anticoagulant interference when used in whole blood samples.
format Online
Article
Text
id pubmed-7807146
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-78071462021-01-22 Diagnostic accuracy of a bovine specific electronic beta-hydroxybutyrate handheld meter in fresh blood and stored serum samples Rodriguez, Z. Caixeta, L.S. Cramer, G. Vet Anim Sci Article This study aims to evaluate the diagnostic accuracy of the bovine specific beta-hydroxybutyrate (BHB) meter Nova Vet (NVET). We evaluated the accuracy and agreement of the NVET in fresh blood and thawed serum with the reference laboratory assay; and the repeatability, the interference by anticoagulants, and the optimum slope calibration factor. Individual blood samples were collected from 200 Holstein and crossbred cows between 3 and 14 days post-calving from 13 dairy herds in Minnesota. Using a laboratory assay with a cut point of 1.2 BHB mmol/L hyperketonemia prevalence was 10.6% (95% CI: 6.7, 15.8). The sensitivity of NVET in blood and serum was 100.0% while the specificity was 98.3 and 97.7% respectively. The agreement between NVET and the laboratory assay was the highest using blood samples (concordance correlation coefficient –CCC = 96.2, 95% CI: 95.0, 97.1. The coefficient of variation including within day (intra-meter), between- days, and -batches was 13.4% when testing blood samples. Minimal interference was observed with the use of anticoagulants (K-EDTA and Li-Heparin, CCC 0.90 and 0.93 respectively) in reference to whole blood without anticoagulant. The best calibration slope factor in serum was 1.0 (Youden's index: 0.98). Results suggest that the NVET device maintained a high accuracy and precision to quantified BHB concentration when applied in fresh blood and thawed serum under field conditions using the default calibration slope (1.0), and with minimal anticoagulant interference when used in whole blood samples. Elsevier 2020-12-14 /pmc/articles/PMC7807146/ /pubmed/33490711 http://dx.doi.org/10.1016/j.vas.2020.100159 Text en © 2020 The Authors. Published by Elsevier Ltd. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Rodriguez, Z.
Caixeta, L.S.
Cramer, G.
Diagnostic accuracy of a bovine specific electronic beta-hydroxybutyrate handheld meter in fresh blood and stored serum samples
title Diagnostic accuracy of a bovine specific electronic beta-hydroxybutyrate handheld meter in fresh blood and stored serum samples
title_full Diagnostic accuracy of a bovine specific electronic beta-hydroxybutyrate handheld meter in fresh blood and stored serum samples
title_fullStr Diagnostic accuracy of a bovine specific electronic beta-hydroxybutyrate handheld meter in fresh blood and stored serum samples
title_full_unstemmed Diagnostic accuracy of a bovine specific electronic beta-hydroxybutyrate handheld meter in fresh blood and stored serum samples
title_short Diagnostic accuracy of a bovine specific electronic beta-hydroxybutyrate handheld meter in fresh blood and stored serum samples
title_sort diagnostic accuracy of a bovine specific electronic beta-hydroxybutyrate handheld meter in fresh blood and stored serum samples
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7807146/
https://www.ncbi.nlm.nih.gov/pubmed/33490711
http://dx.doi.org/10.1016/j.vas.2020.100159
work_keys_str_mv AT rodriguezz diagnosticaccuracyofabovinespecificelectronicbetahydroxybutyratehandheldmeterinfreshbloodandstoredserumsamples
AT caixetals diagnosticaccuracyofabovinespecificelectronicbetahydroxybutyratehandheldmeterinfreshbloodandstoredserumsamples
AT cramerg diagnosticaccuracyofabovinespecificelectronicbetahydroxybutyratehandheldmeterinfreshbloodandstoredserumsamples