Cargando…
Dosimetric end-to-end tests in a national audit of 3D conformal radiotherapy
BACKGROUND AND PURPOSE: Independent dosimetry audits improve quality and safety of radiation therapy. This work reports on design and findings of a comprehensive 3D conformal radiotherapy (3D-CRT) Level III audit. MATERIALS AND METHODS: The audit was conducted as onsite audit using an anthropomorphi...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7807562/ https://www.ncbi.nlm.nih.gov/pubmed/33458381 http://dx.doi.org/10.1016/j.phro.2018.03.006 |
_version_ | 1783636767523471360 |
---|---|
author | Lehmann, Joerg Alves, Andrew Dunn, Leon Shaw, Maddison Kenny, John Keehan, Stephanie Supple, Jeremy Gibbons, Francis Manktelow, Sophie Oliver, Chris Kron, Tomas Williams, Ivan Lye, Jessica |
author_facet | Lehmann, Joerg Alves, Andrew Dunn, Leon Shaw, Maddison Kenny, John Keehan, Stephanie Supple, Jeremy Gibbons, Francis Manktelow, Sophie Oliver, Chris Kron, Tomas Williams, Ivan Lye, Jessica |
author_sort | Lehmann, Joerg |
collection | PubMed |
description | BACKGROUND AND PURPOSE: Independent dosimetry audits improve quality and safety of radiation therapy. This work reports on design and findings of a comprehensive 3D conformal radiotherapy (3D-CRT) Level III audit. MATERIALS AND METHODS: The audit was conducted as onsite audit using an anthropomorphic thorax phantom in an end-to-end test by the Australian Clinical Dosimetry Service (ACDS). Absolute dose point measurements were performed with Farmer-type ionization chambers. The audited treatment plans included open and half blocked fields, wedges and lung inhomogeneities. Audit results were determined as Pass Optimal Level (deviations within 3.3%), Pass Action Level (greater than 3.3% but within 5%) and Out of Tolerance (beyond 5%), as well as Reported Not Scored (RNS). The audit has been performed between July 2012 and January 2018 on 94 occasions, covering approximately 90% of all Australian facilities. RESULTS: The audit pass rate was 87% (53% optimal). Fifty recommendations were given, mainly related to planning system commissioning. Dose overestimation behind low density inhomogeneities by the analytical anisotropic algorithm (AAA) was identified across facilities and found to extend to beam setups which resemble a typical breast cancer treatment beam placement. RNS measurements inside lung showed a variation in the opposite direction: AAA under-dosed a target beyond lung and over-dosed the lung upstream and downstream of the target. Results also highlighted shortcomings of some superposition and convolution algorithms in modelling large angle wedges. CONCLUSIONS: This audit showed that 3D-CRT dosimetry audits remain relevant and can identify fundamental global and local problems that also affect advanced treatments. |
format | Online Article Text |
id | pubmed-7807562 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-78075622021-01-14 Dosimetric end-to-end tests in a national audit of 3D conformal radiotherapy Lehmann, Joerg Alves, Andrew Dunn, Leon Shaw, Maddison Kenny, John Keehan, Stephanie Supple, Jeremy Gibbons, Francis Manktelow, Sophie Oliver, Chris Kron, Tomas Williams, Ivan Lye, Jessica Phys Imaging Radiat Oncol Original Research Article BACKGROUND AND PURPOSE: Independent dosimetry audits improve quality and safety of radiation therapy. This work reports on design and findings of a comprehensive 3D conformal radiotherapy (3D-CRT) Level III audit. MATERIALS AND METHODS: The audit was conducted as onsite audit using an anthropomorphic thorax phantom in an end-to-end test by the Australian Clinical Dosimetry Service (ACDS). Absolute dose point measurements were performed with Farmer-type ionization chambers. The audited treatment plans included open and half blocked fields, wedges and lung inhomogeneities. Audit results were determined as Pass Optimal Level (deviations within 3.3%), Pass Action Level (greater than 3.3% but within 5%) and Out of Tolerance (beyond 5%), as well as Reported Not Scored (RNS). The audit has been performed between July 2012 and January 2018 on 94 occasions, covering approximately 90% of all Australian facilities. RESULTS: The audit pass rate was 87% (53% optimal). Fifty recommendations were given, mainly related to planning system commissioning. Dose overestimation behind low density inhomogeneities by the analytical anisotropic algorithm (AAA) was identified across facilities and found to extend to beam setups which resemble a typical breast cancer treatment beam placement. RNS measurements inside lung showed a variation in the opposite direction: AAA under-dosed a target beyond lung and over-dosed the lung upstream and downstream of the target. Results also highlighted shortcomings of some superposition and convolution algorithms in modelling large angle wedges. CONCLUSIONS: This audit showed that 3D-CRT dosimetry audits remain relevant and can identify fundamental global and local problems that also affect advanced treatments. Elsevier 2018-04-24 /pmc/articles/PMC7807562/ /pubmed/33458381 http://dx.doi.org/10.1016/j.phro.2018.03.006 Text en Crown Copyright © 2018 Published by Elsevier B.V. on behalf of European Society of Radiotherapy & Oncology. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Research Article Lehmann, Joerg Alves, Andrew Dunn, Leon Shaw, Maddison Kenny, John Keehan, Stephanie Supple, Jeremy Gibbons, Francis Manktelow, Sophie Oliver, Chris Kron, Tomas Williams, Ivan Lye, Jessica Dosimetric end-to-end tests in a national audit of 3D conformal radiotherapy |
title | Dosimetric end-to-end tests in a national audit of 3D conformal radiotherapy |
title_full | Dosimetric end-to-end tests in a national audit of 3D conformal radiotherapy |
title_fullStr | Dosimetric end-to-end tests in a national audit of 3D conformal radiotherapy |
title_full_unstemmed | Dosimetric end-to-end tests in a national audit of 3D conformal radiotherapy |
title_short | Dosimetric end-to-end tests in a national audit of 3D conformal radiotherapy |
title_sort | dosimetric end-to-end tests in a national audit of 3d conformal radiotherapy |
topic | Original Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7807562/ https://www.ncbi.nlm.nih.gov/pubmed/33458381 http://dx.doi.org/10.1016/j.phro.2018.03.006 |
work_keys_str_mv | AT lehmannjoerg dosimetricendtoendtestsinanationalauditof3dconformalradiotherapy AT alvesandrew dosimetricendtoendtestsinanationalauditof3dconformalradiotherapy AT dunnleon dosimetricendtoendtestsinanationalauditof3dconformalradiotherapy AT shawmaddison dosimetricendtoendtestsinanationalauditof3dconformalradiotherapy AT kennyjohn dosimetricendtoendtestsinanationalauditof3dconformalradiotherapy AT keehanstephanie dosimetricendtoendtestsinanationalauditof3dconformalradiotherapy AT supplejeremy dosimetricendtoendtestsinanationalauditof3dconformalradiotherapy AT gibbonsfrancis dosimetricendtoendtestsinanationalauditof3dconformalradiotherapy AT manktelowsophie dosimetricendtoendtestsinanationalauditof3dconformalradiotherapy AT oliverchris dosimetricendtoendtestsinanationalauditof3dconformalradiotherapy AT krontomas dosimetricendtoendtestsinanationalauditof3dconformalradiotherapy AT williamsivan dosimetricendtoendtestsinanationalauditof3dconformalradiotherapy AT lyejessica dosimetricendtoendtestsinanationalauditof3dconformalradiotherapy |