BACKGROUND AND PURPOSE: Magnetic Resonance (MR)-Only radiotherapy requires a method for matching image with on-treatment Cone Beam Computed Tomography (CBCT). This study aimed to investigate the accuracy of MR-CBCT soft-tissue matching for prostate MR-only radiotherapy. MATERIALS AND METHODS: Three...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7807576/ https://www.ncbi.nlm.nih.gov/pubmed/33458295 http://dx.doi.org/10.1016/j.phro.2019.11.005 |
_version_ | 1783636770500378624 |
---|---|
author | Wyatt, Jonathan J. Brooks, Rachel L. Ainslie, Dean Wilkins, Emily Raven, Elizabeth Pilling, Karen Pearson, Rachel A. McCallum, Hazel M. |
author_facet | Wyatt, Jonathan J. Brooks, Rachel L. Ainslie, Dean Wilkins, Emily Raven, Elizabeth Pilling, Karen Pearson, Rachel A. McCallum, Hazel M. |
author_sort | Wyatt, Jonathan J. |
collection | PubMed |
description | BACKGROUND AND PURPOSE: Magnetic Resonance (MR)-Only radiotherapy requires a method for matching image with on-treatment Cone Beam Computed Tomography (CBCT). This study aimed to investigate the accuracy of MR-CBCT soft-tissue matching for prostate MR-only radiotherapy. MATERIALS AND METHODS: Three patient cohorts were used, with all patients receiving MR and CT scans. For the first cohort (10 patients) the first fraction CBCT was automatically rigidly registered to the CT and MR scans and the MR-CT registration predicted using the MR-CBCT and CT-CBCT registrations. This was compared to the automatic MR-CT registration. For the second and third cohorts (five patients each) the first fraction CBCT was independently matched to the CT and MR by four radiographers, the MR-CBCT and CT-CBCT matches compared and the inter-observer variability assessed. The second cohort used a CT-based structure set and the third a MR-based structure set with the MR relabelled as a ‘CT’. RESULTS: The mean difference between predicted and actual MR-CT registrations was [Formula: see text] (s.e.m.). Radiographer MR-CBCT registrations were not significantly different to CT-CBCT, with mean differences in soft-tissue match [Formula: see text] and all except one difference [Formula: see text]. This was less than the MR-CBCT inter-observer limits of agreement [Formula: see text] (vertical, longitudinal, lateral), which were similar ([Formula: see text]) to CT-CBCT. CONCLUSIONS: MR-CBCT soft-tissue matching is not significantly different to CT-CBCT. Relabelling the MR as a ‘CT’ does not appear to change the automatic registration. This suggests that MR-CBCT soft-tissue matching is feasible and accurate. |
format | Online Article Text |
id | pubmed-7807576 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-78075762021-01-14 The accuracy of Magnetic Resonance – Cone Beam Computed Tomography soft-tissue matching for prostate radiotherapy Wyatt, Jonathan J. Brooks, Rachel L. Ainslie, Dean Wilkins, Emily Raven, Elizabeth Pilling, Karen Pearson, Rachel A. McCallum, Hazel M. Phys Imaging Radiat Oncol Original Research Article BACKGROUND AND PURPOSE: Magnetic Resonance (MR)-Only radiotherapy requires a method for matching image with on-treatment Cone Beam Computed Tomography (CBCT). This study aimed to investigate the accuracy of MR-CBCT soft-tissue matching for prostate MR-only radiotherapy. MATERIALS AND METHODS: Three patient cohorts were used, with all patients receiving MR and CT scans. For the first cohort (10 patients) the first fraction CBCT was automatically rigidly registered to the CT and MR scans and the MR-CT registration predicted using the MR-CBCT and CT-CBCT registrations. This was compared to the automatic MR-CT registration. For the second and third cohorts (five patients each) the first fraction CBCT was independently matched to the CT and MR by four radiographers, the MR-CBCT and CT-CBCT matches compared and the inter-observer variability assessed. The second cohort used a CT-based structure set and the third a MR-based structure set with the MR relabelled as a ‘CT’. RESULTS: The mean difference between predicted and actual MR-CT registrations was [Formula: see text] (s.e.m.). Radiographer MR-CBCT registrations were not significantly different to CT-CBCT, with mean differences in soft-tissue match [Formula: see text] and all except one difference [Formula: see text]. This was less than the MR-CBCT inter-observer limits of agreement [Formula: see text] (vertical, longitudinal, lateral), which were similar ([Formula: see text]) to CT-CBCT. CONCLUSIONS: MR-CBCT soft-tissue matching is not significantly different to CT-CBCT. Relabelling the MR as a ‘CT’ does not appear to change the automatic registration. This suggests that MR-CBCT soft-tissue matching is feasible and accurate. Elsevier 2019-12-05 /pmc/articles/PMC7807576/ /pubmed/33458295 http://dx.doi.org/10.1016/j.phro.2019.11.005 Text en © 2019 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Research Article Wyatt, Jonathan J. Brooks, Rachel L. Ainslie, Dean Wilkins, Emily Raven, Elizabeth Pilling, Karen Pearson, Rachel A. McCallum, Hazel M. The accuracy of Magnetic Resonance – Cone Beam Computed Tomography soft-tissue matching for prostate radiotherapy |
title | The accuracy of Magnetic Resonance – Cone Beam Computed Tomography soft-tissue matching for prostate radiotherapy |
title_full | The accuracy of Magnetic Resonance – Cone Beam Computed Tomography soft-tissue matching for prostate radiotherapy |
title_fullStr | The accuracy of Magnetic Resonance – Cone Beam Computed Tomography soft-tissue matching for prostate radiotherapy |
title_full_unstemmed | The accuracy of Magnetic Resonance – Cone Beam Computed Tomography soft-tissue matching for prostate radiotherapy |
title_short | The accuracy of Magnetic Resonance – Cone Beam Computed Tomography soft-tissue matching for prostate radiotherapy |
title_sort | accuracy of magnetic resonance – cone beam computed tomography soft-tissue matching for prostate radiotherapy |
topic | Original Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7807576/ https://www.ncbi.nlm.nih.gov/pubmed/33458295 http://dx.doi.org/10.1016/j.phro.2019.11.005 |
work_keys_str_mv | AT wyattjonathanj theaccuracyofmagneticresonanceconebeamcomputedtomographysofttissuematchingforprostateradiotherapy AT brooksrachell theaccuracyofmagneticresonanceconebeamcomputedtomographysofttissuematchingforprostateradiotherapy AT ainsliedean theaccuracyofmagneticresonanceconebeamcomputedtomographysofttissuematchingforprostateradiotherapy AT wilkinsemily theaccuracyofmagneticresonanceconebeamcomputedtomographysofttissuematchingforprostateradiotherapy AT ravenelizabeth theaccuracyofmagneticresonanceconebeamcomputedtomographysofttissuematchingforprostateradiotherapy AT pillingkaren theaccuracyofmagneticresonanceconebeamcomputedtomographysofttissuematchingforprostateradiotherapy AT pearsonrachela theaccuracyofmagneticresonanceconebeamcomputedtomographysofttissuematchingforprostateradiotherapy AT mccallumhazelm theaccuracyofmagneticresonanceconebeamcomputedtomographysofttissuematchingforprostateradiotherapy AT wyattjonathanj accuracyofmagneticresonanceconebeamcomputedtomographysofttissuematchingforprostateradiotherapy AT brooksrachell accuracyofmagneticresonanceconebeamcomputedtomographysofttissuematchingforprostateradiotherapy AT ainsliedean accuracyofmagneticresonanceconebeamcomputedtomographysofttissuematchingforprostateradiotherapy AT wilkinsemily accuracyofmagneticresonanceconebeamcomputedtomographysofttissuematchingforprostateradiotherapy AT ravenelizabeth accuracyofmagneticresonanceconebeamcomputedtomographysofttissuematchingforprostateradiotherapy AT pillingkaren accuracyofmagneticresonanceconebeamcomputedtomographysofttissuematchingforprostateradiotherapy AT pearsonrachela accuracyofmagneticresonanceconebeamcomputedtomographysofttissuematchingforprostateradiotherapy AT mccallumhazelm accuracyofmagneticresonanceconebeamcomputedtomographysofttissuematchingforprostateradiotherapy |