Cargando…

Clinical and radiobiological evaluation of a method for planning target volume generation dependent on organ-at-risk exclusions in magnetic resonance imaging-based prostate radiotherapy

BACKGROUND AND PURPOSE: Due to a smaller target volume when delineating prostate on magnetic resonance imaging (MRI), margins may be too tight as compared to computed tomography (CT) delineation, potentially reducing tumor control probability (TCP) in prostate radiotherapy. This study evaluated a cl...

Descripción completa

Detalles Bibliográficos
Autores principales: Ruiz, Brian, Feng, Yuanming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7807578/
https://www.ncbi.nlm.nih.gov/pubmed/33458417
http://dx.doi.org/10.1016/j.phro.2018.11.007
_version_ 1783636770979577856
author Ruiz, Brian
Feng, Yuanming
author_facet Ruiz, Brian
Feng, Yuanming
author_sort Ruiz, Brian
collection PubMed
description BACKGROUND AND PURPOSE: Due to a smaller target volume when delineating prostate on magnetic resonance imaging (MRI), margins may be too tight as compared to computed tomography (CT) delineation, potentially reducing tumor control probability (TCP) in prostate radiotherapy. This study evaluated a clinically implemented MRI-based target expansion method to provide adequate margins yet limit organ-at-risk (OAR) dose as compared to CT-based delineation. METHODS AND MATERIALS: Patients in this study were treated to 79.2 Gy in 44 fractions via intensity modulated radiotherapy using an MRI-based expansion method, which excluded OARs when performing a 5 mm isotropic (except 4 mm posterior) expansion from gross tumor volume to clinical target volume (CTV), followed by an isotropic 5 mm expansion to generate the planning target volume (PTV). Ten cases were re-planned using CT-delineated prostate with CTV-to-PTV expansion of isotropic 8 mm, except for a 5 mm posterior expansion, with comparison of PTV volumes, TCP and normal tissue complication probability (NTCP) to the MRI-based method. Under IRB approved protocol, we retrospectively evaluated 51 patients treated with the MRI-based method for acute bladder and rectal toxicity with CTC-AE version 4.0 used for scoring. RESULTS: MRI-based PTV volume differed by 4% compared to CT-based PTV volume. Radiobiological calculated TCP of the MRI-based method was found comparable to CT-based methods with an average equivalent uniform dose of 80.5 Gy and 80.1 Gy respectively. Statistically significant decrease in bladder NTCP (toxicity Grade 2 and above for 5% complications within 5 years post radiotherapy) was observed in the MRI-based method. Outcomes data collected showed 65% and 100% of patients studied experienced Grade 0/1 bladder and rectal acute toxicity respectively. Grade 2 bladder toxicity was indicated in the remaining 35% of patients studied with no Grade 3 toxicity reported. CONCLUSIONS: Results showed comparable PTV volume with MRI-based method, and NTCP was reduced while maintaining TCP. Clinically, bladder and rectal toxicities were observed to be minimal.
format Online
Article
Text
id pubmed-7807578
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-78075782021-01-14 Clinical and radiobiological evaluation of a method for planning target volume generation dependent on organ-at-risk exclusions in magnetic resonance imaging-based prostate radiotherapy Ruiz, Brian Feng, Yuanming Phys Imaging Radiat Oncol Original Research Article BACKGROUND AND PURPOSE: Due to a smaller target volume when delineating prostate on magnetic resonance imaging (MRI), margins may be too tight as compared to computed tomography (CT) delineation, potentially reducing tumor control probability (TCP) in prostate radiotherapy. This study evaluated a clinically implemented MRI-based target expansion method to provide adequate margins yet limit organ-at-risk (OAR) dose as compared to CT-based delineation. METHODS AND MATERIALS: Patients in this study were treated to 79.2 Gy in 44 fractions via intensity modulated radiotherapy using an MRI-based expansion method, which excluded OARs when performing a 5 mm isotropic (except 4 mm posterior) expansion from gross tumor volume to clinical target volume (CTV), followed by an isotropic 5 mm expansion to generate the planning target volume (PTV). Ten cases were re-planned using CT-delineated prostate with CTV-to-PTV expansion of isotropic 8 mm, except for a 5 mm posterior expansion, with comparison of PTV volumes, TCP and normal tissue complication probability (NTCP) to the MRI-based method. Under IRB approved protocol, we retrospectively evaluated 51 patients treated with the MRI-based method for acute bladder and rectal toxicity with CTC-AE version 4.0 used for scoring. RESULTS: MRI-based PTV volume differed by 4% compared to CT-based PTV volume. Radiobiological calculated TCP of the MRI-based method was found comparable to CT-based methods with an average equivalent uniform dose of 80.5 Gy and 80.1 Gy respectively. Statistically significant decrease in bladder NTCP (toxicity Grade 2 and above for 5% complications within 5 years post radiotherapy) was observed in the MRI-based method. Outcomes data collected showed 65% and 100% of patients studied experienced Grade 0/1 bladder and rectal acute toxicity respectively. Grade 2 bladder toxicity was indicated in the remaining 35% of patients studied with no Grade 3 toxicity reported. CONCLUSIONS: Results showed comparable PTV volume with MRI-based method, and NTCP was reduced while maintaining TCP. Clinically, bladder and rectal toxicities were observed to be minimal. Elsevier 2018-12-07 /pmc/articles/PMC7807578/ /pubmed/33458417 http://dx.doi.org/10.1016/j.phro.2018.11.007 Text en © 2018 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research Article
Ruiz, Brian
Feng, Yuanming
Clinical and radiobiological evaluation of a method for planning target volume generation dependent on organ-at-risk exclusions in magnetic resonance imaging-based prostate radiotherapy
title Clinical and radiobiological evaluation of a method for planning target volume generation dependent on organ-at-risk exclusions in magnetic resonance imaging-based prostate radiotherapy
title_full Clinical and radiobiological evaluation of a method for planning target volume generation dependent on organ-at-risk exclusions in magnetic resonance imaging-based prostate radiotherapy
title_fullStr Clinical and radiobiological evaluation of a method for planning target volume generation dependent on organ-at-risk exclusions in magnetic resonance imaging-based prostate radiotherapy
title_full_unstemmed Clinical and radiobiological evaluation of a method for planning target volume generation dependent on organ-at-risk exclusions in magnetic resonance imaging-based prostate radiotherapy
title_short Clinical and radiobiological evaluation of a method for planning target volume generation dependent on organ-at-risk exclusions in magnetic resonance imaging-based prostate radiotherapy
title_sort clinical and radiobiological evaluation of a method for planning target volume generation dependent on organ-at-risk exclusions in magnetic resonance imaging-based prostate radiotherapy
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7807578/
https://www.ncbi.nlm.nih.gov/pubmed/33458417
http://dx.doi.org/10.1016/j.phro.2018.11.007
work_keys_str_mv AT ruizbrian clinicalandradiobiologicalevaluationofamethodforplanningtargetvolumegenerationdependentonorganatriskexclusionsinmagneticresonanceimagingbasedprostateradiotherapy
AT fengyuanming clinicalandradiobiologicalevaluationofamethodforplanningtargetvolumegenerationdependentonorganatriskexclusionsinmagneticresonanceimagingbasedprostateradiotherapy