Cargando…

Fast 4D cone-beam CT from 60 s acquisitions

BACKGROUND & PURPOSE: Four dimensional Cone beam CT (CBCT) has many potential benefits for radiotherapy but suffers from poor image quality, long acquisition times, and/or long reconstruction times. In this work we present a fast iterative reconstruction algorithm for 4D reconstruction of fast a...

Descripción completa

Detalles Bibliográficos
Autores principales: Hansen, David C., Sørensen, Thomas Sangild
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7807579/
https://www.ncbi.nlm.nih.gov/pubmed/33458372
http://dx.doi.org/10.1016/j.phro.2018.02.004
_version_ 1783636771221798912
author Hansen, David C.
Sørensen, Thomas Sangild
author_facet Hansen, David C.
Sørensen, Thomas Sangild
author_sort Hansen, David C.
collection PubMed
description BACKGROUND & PURPOSE: Four dimensional Cone beam CT (CBCT) has many potential benefits for radiotherapy but suffers from poor image quality, long acquisition times, and/or long reconstruction times. In this work we present a fast iterative reconstruction algorithm for 4D reconstruction of fast acquisition cone beam CT, as well as a new method for temporal regularization and compare to state of the art methods for 4D CBCT. MATERIALS & METHODS: Regularization parameters for the iterative algorithms were found automatically via computer optimization on 60 s acquisitions using the XCAT phantom. Nineteen lung cancer patients were scanned with 60 s arcs using the onboard image on a Varian trilogy linear accelerator. Images were reconstructed using an accelerated ordered subset algorithm. A frequency based temporal regularization algorithm was developed and compared to the McKinnon-Bates algorithm, 4D total variation and prior images compressed sensing (PICCS). RESULTS: All reconstructions were completed in 60 s or less. The proposed method provided a structural similarity of 0.915, compared with 0.786 for the classic McKinnon-bates method. For the patient study, it provided fewer image artefacts than PICCS, and better spatial resolution than 4D TV. CONCLUSION: Four dimensional iterative CBCT reconstruction was done in less than 60 s, demonstrating the clinical feasibility. The frequency based method outperformed 4D total variation and PICCS on the simulated data, and for patients allowed for tumor location based on 60 s acquisitions, even for slowly breathing patients. It should thus be suitable for routine clinical use.
format Online
Article
Text
id pubmed-7807579
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-78075792021-01-14 Fast 4D cone-beam CT from 60 s acquisitions Hansen, David C. Sørensen, Thomas Sangild Phys Imaging Radiat Oncol Original Research Article BACKGROUND & PURPOSE: Four dimensional Cone beam CT (CBCT) has many potential benefits for radiotherapy but suffers from poor image quality, long acquisition times, and/or long reconstruction times. In this work we present a fast iterative reconstruction algorithm for 4D reconstruction of fast acquisition cone beam CT, as well as a new method for temporal regularization and compare to state of the art methods for 4D CBCT. MATERIALS & METHODS: Regularization parameters for the iterative algorithms were found automatically via computer optimization on 60 s acquisitions using the XCAT phantom. Nineteen lung cancer patients were scanned with 60 s arcs using the onboard image on a Varian trilogy linear accelerator. Images were reconstructed using an accelerated ordered subset algorithm. A frequency based temporal regularization algorithm was developed and compared to the McKinnon-Bates algorithm, 4D total variation and prior images compressed sensing (PICCS). RESULTS: All reconstructions were completed in 60 s or less. The proposed method provided a structural similarity of 0.915, compared with 0.786 for the classic McKinnon-bates method. For the patient study, it provided fewer image artefacts than PICCS, and better spatial resolution than 4D TV. CONCLUSION: Four dimensional iterative CBCT reconstruction was done in less than 60 s, demonstrating the clinical feasibility. The frequency based method outperformed 4D total variation and PICCS on the simulated data, and for patients allowed for tumor location based on 60 s acquisitions, even for slowly breathing patients. It should thus be suitable for routine clinical use. Elsevier 2018-03-08 /pmc/articles/PMC7807579/ /pubmed/33458372 http://dx.doi.org/10.1016/j.phro.2018.02.004 Text en © 2018 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research Article
Hansen, David C.
Sørensen, Thomas Sangild
Fast 4D cone-beam CT from 60 s acquisitions
title Fast 4D cone-beam CT from 60 s acquisitions
title_full Fast 4D cone-beam CT from 60 s acquisitions
title_fullStr Fast 4D cone-beam CT from 60 s acquisitions
title_full_unstemmed Fast 4D cone-beam CT from 60 s acquisitions
title_short Fast 4D cone-beam CT from 60 s acquisitions
title_sort fast 4d cone-beam ct from 60 s acquisitions
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7807579/
https://www.ncbi.nlm.nih.gov/pubmed/33458372
http://dx.doi.org/10.1016/j.phro.2018.02.004
work_keys_str_mv AT hansendavidc fast4dconebeamctfrom60sacquisitions
AT sørensenthomassangild fast4dconebeamctfrom60sacquisitions