Corneal complication after femtosecond laser-assisted cataract surgery: A case report

RATIONALE: The femtosecond laser LDV Z 8 is unique, and the only femtosecond laser used in ophthalmic microsurgery, which is characterized by low-energy near-infrared (1030 nm) femtosecond single pulses in the nano-Joule range and a very high repetition rate in the MHz range. To the best of our know...

Descripción completa

Detalles Bibliográficos
Autores principales: Chlasta-Twardzik, Edyta, Nowińska, Anna, Wylęgała, Edward
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7808488/
https://www.ncbi.nlm.nih.gov/pubmed/33466143
http://dx.doi.org/10.1097/MD.0000000000024013
_version_ 1783636908849496064
author Chlasta-Twardzik, Edyta
Nowińska, Anna
Wylęgała, Edward
author_facet Chlasta-Twardzik, Edyta
Nowińska, Anna
Wylęgała, Edward
author_sort Chlasta-Twardzik, Edyta
collection PubMed
description RATIONALE: The femtosecond laser LDV Z 8 is unique, and the only femtosecond laser used in ophthalmic microsurgery, which is characterized by low-energy near-infrared (1030 nm) femtosecond single pulses in the nano-Joule range and a very high repetition rate in the MHz range. To the best of our knowledge, this is the first description of unintentional partial corneal incision in the anterior part of a stroma by the femtosecond laser. PATIENT CONCERNS: A 79-year-old patient was referred to our clinic for cataract surgery. On admission, we diagnosed mature cataract of the left eye and pseudophakic of the right eye. The patient was qualified for the Femtosecond Laser-Assisted Cataract Surgery (FLACS). Unexpectedly during FLACS procedure after lens fragmentation the surgeon observed unexpected paracentral incision in the cornea. DIAGNOSIS: The corneal incision line between 4 to 8 o’clock was observed. In vivo confocal microscopy was performed to assess the morphology and depth of the corneal wound. The corneal incision covered the epithelium, Bowman's membrane and stroma of the cornea reached a depth of 336 um. INTERVENTIONS: The patient was under increased ophthalmologic controls; follow up with typical ophthalmic examinations and confocal microscopy was performed. OUTCOMES: In 2-year follow-up period, this complication had no effect on postoperative visual function, the patient had no visual problems and obtained the final BCVA 5/5. There is no dislocation of the lens in 2 years follow-up. LESSONS: Low pulse energy and high pulse frequency in the LDV Z8 causes a low traumatization of tissues. In a 2-year follow-up, the corneal incision line could be observed on the slit lamp examination without long-term visual consequences of this complication. In our opinion, the most likely cause of this complication was human error and lack of communication between medical personnel. The operation team should be alert and great caution must be exercised during the procedure and check the laser settings parameters carefully each time.
format Online
Article
Text
id pubmed-7808488
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-78084882021-01-15 Corneal complication after femtosecond laser-assisted cataract surgery: A case report Chlasta-Twardzik, Edyta Nowińska, Anna Wylęgała, Edward Medicine (Baltimore) 5800 RATIONALE: The femtosecond laser LDV Z 8 is unique, and the only femtosecond laser used in ophthalmic microsurgery, which is characterized by low-energy near-infrared (1030 nm) femtosecond single pulses in the nano-Joule range and a very high repetition rate in the MHz range. To the best of our knowledge, this is the first description of unintentional partial corneal incision in the anterior part of a stroma by the femtosecond laser. PATIENT CONCERNS: A 79-year-old patient was referred to our clinic for cataract surgery. On admission, we diagnosed mature cataract of the left eye and pseudophakic of the right eye. The patient was qualified for the Femtosecond Laser-Assisted Cataract Surgery (FLACS). Unexpectedly during FLACS procedure after lens fragmentation the surgeon observed unexpected paracentral incision in the cornea. DIAGNOSIS: The corneal incision line between 4 to 8 o’clock was observed. In vivo confocal microscopy was performed to assess the morphology and depth of the corneal wound. The corneal incision covered the epithelium, Bowman's membrane and stroma of the cornea reached a depth of 336 um. INTERVENTIONS: The patient was under increased ophthalmologic controls; follow up with typical ophthalmic examinations and confocal microscopy was performed. OUTCOMES: In 2-year follow-up period, this complication had no effect on postoperative visual function, the patient had no visual problems and obtained the final BCVA 5/5. There is no dislocation of the lens in 2 years follow-up. LESSONS: Low pulse energy and high pulse frequency in the LDV Z8 causes a low traumatization of tissues. In a 2-year follow-up, the corneal incision line could be observed on the slit lamp examination without long-term visual consequences of this complication. In our opinion, the most likely cause of this complication was human error and lack of communication between medical personnel. The operation team should be alert and great caution must be exercised during the procedure and check the laser settings parameters carefully each time. Lippincott Williams & Wilkins 2021-01-15 /pmc/articles/PMC7808488/ /pubmed/33466143 http://dx.doi.org/10.1097/MD.0000000000024013 Text en Copyright © 2021 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0 (https://creativecommons.org/licenses/by/4.0/)
spellingShingle 5800
Chlasta-Twardzik, Edyta
Nowińska, Anna
Wylęgała, Edward
Corneal complication after femtosecond laser-assisted cataract surgery: A case report
title Corneal complication after femtosecond laser-assisted cataract surgery: A case report
title_full Corneal complication after femtosecond laser-assisted cataract surgery: A case report
title_fullStr Corneal complication after femtosecond laser-assisted cataract surgery: A case report
title_full_unstemmed Corneal complication after femtosecond laser-assisted cataract surgery: A case report
title_short Corneal complication after femtosecond laser-assisted cataract surgery: A case report
title_sort corneal complication after femtosecond laser-assisted cataract surgery: a case report
topic 5800
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7808488/
https://www.ncbi.nlm.nih.gov/pubmed/33466143
http://dx.doi.org/10.1097/MD.0000000000024013
work_keys_str_mv AT chlastatwardzikedyta cornealcomplicationafterfemtosecondlaserassistedcataractsurgeryacasereport
AT nowinskaanna cornealcomplicationafterfemtosecondlaserassistedcataractsurgeryacasereport
AT wylegałaedward cornealcomplicationafterfemtosecondlaserassistedcataractsurgeryacasereport