Cargando…

Prospective study of EUS-guided tissue acquisition with a 20G core biopsy needle with a forward bevel for solid pancreatic mass

There is a growing need for tissue collection for immunostaining and genetic testing. Recently, several fine-needle biopsy needles are commercially available for endoscopic ultrasound-guided tissue acquisition. This prospective historical controlled study evaluates a 20G core biopsy needle with a fo...

Descripción completa

Detalles Bibliográficos
Autores principales: Kanata, Ryo, Sasaki, Takashi, Matsuyama, Masato, Ishigaki, Kazunaga, Yamada, Ikuhiro, Ozaka, Masato, Takano, Koichi, Takazawa, Yutaka, Ishizuka, Naoki, Sasahira, Naoki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7808531/
https://www.ncbi.nlm.nih.gov/pubmed/33466194
http://dx.doi.org/10.1097/MD.0000000000024193
_version_ 1783636919059480576
author Kanata, Ryo
Sasaki, Takashi
Matsuyama, Masato
Ishigaki, Kazunaga
Yamada, Ikuhiro
Ozaka, Masato
Takano, Koichi
Takazawa, Yutaka
Ishizuka, Naoki
Sasahira, Naoki
author_facet Kanata, Ryo
Sasaki, Takashi
Matsuyama, Masato
Ishigaki, Kazunaga
Yamada, Ikuhiro
Ozaka, Masato
Takano, Koichi
Takazawa, Yutaka
Ishizuka, Naoki
Sasahira, Naoki
author_sort Kanata, Ryo
collection PubMed
description There is a growing need for tissue collection for immunostaining and genetic testing. Recently, several fine-needle biopsy needles are commercially available for endoscopic ultrasound-guided tissue acquisition. This prospective historical controlled study evaluates a 20G core biopsy needle with a forward bevel for solid pancreatic masses larger than 15 mm in diameter. The primary endpoint was the accuracy of histological diagnosis. The secondary endpoints included technical success rate, sample adequacy for histology, cytological diagnostic accuracy, and adverse events. Seventy consecutive patients were enrolled between January and October 2017. We achieved technical success in all cases regardless of the puncture sites or the endosonographer's experience. The final diagnoses were neoplasms in 67 patients (95.7%; pancreatic cancer in 65 patients, neuroendocrine neoplasm in 1, and malignant lymphoma in 1) and benign lesions in 3 patients (4.3%; autoimmune pancreatitis in 2 patients and mass-forming pancreatitis in 1). The obtained specimens were adequate for histological evaluation in all cases and the histological accuracy was 91.4% (95% confidence interval, 82.3–96.8%, P < .05) with the sensitivity and specificity of 91.0% and 100%, respectively. The cytological diagnostic accuracy was 95.7% and all patients were accurately diagnosed by combining cytological and histological examinations. As for adverse events, an asymptomatic needle fracture occurred in 1 case (1.4%). This 20G core biopsy needle with a forward bevel showed a high accuracy of histological diagnosis for solid pancreatic masses.
format Online
Article
Text
id pubmed-7808531
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-78085312021-01-21 Prospective study of EUS-guided tissue acquisition with a 20G core biopsy needle with a forward bevel for solid pancreatic mass Kanata, Ryo Sasaki, Takashi Matsuyama, Masato Ishigaki, Kazunaga Yamada, Ikuhiro Ozaka, Masato Takano, Koichi Takazawa, Yutaka Ishizuka, Naoki Sasahira, Naoki Medicine (Baltimore) 4500 There is a growing need for tissue collection for immunostaining and genetic testing. Recently, several fine-needle biopsy needles are commercially available for endoscopic ultrasound-guided tissue acquisition. This prospective historical controlled study evaluates a 20G core biopsy needle with a forward bevel for solid pancreatic masses larger than 15 mm in diameter. The primary endpoint was the accuracy of histological diagnosis. The secondary endpoints included technical success rate, sample adequacy for histology, cytological diagnostic accuracy, and adverse events. Seventy consecutive patients were enrolled between January and October 2017. We achieved technical success in all cases regardless of the puncture sites or the endosonographer's experience. The final diagnoses were neoplasms in 67 patients (95.7%; pancreatic cancer in 65 patients, neuroendocrine neoplasm in 1, and malignant lymphoma in 1) and benign lesions in 3 patients (4.3%; autoimmune pancreatitis in 2 patients and mass-forming pancreatitis in 1). The obtained specimens were adequate for histological evaluation in all cases and the histological accuracy was 91.4% (95% confidence interval, 82.3–96.8%, P < .05) with the sensitivity and specificity of 91.0% and 100%, respectively. The cytological diagnostic accuracy was 95.7% and all patients were accurately diagnosed by combining cytological and histological examinations. As for adverse events, an asymptomatic needle fracture occurred in 1 case (1.4%). This 20G core biopsy needle with a forward bevel showed a high accuracy of histological diagnosis for solid pancreatic masses. Lippincott Williams & Wilkins 2021-01-15 /pmc/articles/PMC7808531/ /pubmed/33466194 http://dx.doi.org/10.1097/MD.0000000000024193 Text en Copyright © 2021 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/)
spellingShingle 4500
Kanata, Ryo
Sasaki, Takashi
Matsuyama, Masato
Ishigaki, Kazunaga
Yamada, Ikuhiro
Ozaka, Masato
Takano, Koichi
Takazawa, Yutaka
Ishizuka, Naoki
Sasahira, Naoki
Prospective study of EUS-guided tissue acquisition with a 20G core biopsy needle with a forward bevel for solid pancreatic mass
title Prospective study of EUS-guided tissue acquisition with a 20G core biopsy needle with a forward bevel for solid pancreatic mass
title_full Prospective study of EUS-guided tissue acquisition with a 20G core biopsy needle with a forward bevel for solid pancreatic mass
title_fullStr Prospective study of EUS-guided tissue acquisition with a 20G core biopsy needle with a forward bevel for solid pancreatic mass
title_full_unstemmed Prospective study of EUS-guided tissue acquisition with a 20G core biopsy needle with a forward bevel for solid pancreatic mass
title_short Prospective study of EUS-guided tissue acquisition with a 20G core biopsy needle with a forward bevel for solid pancreatic mass
title_sort prospective study of eus-guided tissue acquisition with a 20g core biopsy needle with a forward bevel for solid pancreatic mass
topic 4500
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7808531/
https://www.ncbi.nlm.nih.gov/pubmed/33466194
http://dx.doi.org/10.1097/MD.0000000000024193
work_keys_str_mv AT kanataryo prospectivestudyofeusguidedtissueacquisitionwitha20gcorebiopsyneedlewithaforwardbevelforsolidpancreaticmass
AT sasakitakashi prospectivestudyofeusguidedtissueacquisitionwitha20gcorebiopsyneedlewithaforwardbevelforsolidpancreaticmass
AT matsuyamamasato prospectivestudyofeusguidedtissueacquisitionwitha20gcorebiopsyneedlewithaforwardbevelforsolidpancreaticmass
AT ishigakikazunaga prospectivestudyofeusguidedtissueacquisitionwitha20gcorebiopsyneedlewithaforwardbevelforsolidpancreaticmass
AT yamadaikuhiro prospectivestudyofeusguidedtissueacquisitionwitha20gcorebiopsyneedlewithaforwardbevelforsolidpancreaticmass
AT ozakamasato prospectivestudyofeusguidedtissueacquisitionwitha20gcorebiopsyneedlewithaforwardbevelforsolidpancreaticmass
AT takanokoichi prospectivestudyofeusguidedtissueacquisitionwitha20gcorebiopsyneedlewithaforwardbevelforsolidpancreaticmass
AT takazawayutaka prospectivestudyofeusguidedtissueacquisitionwitha20gcorebiopsyneedlewithaforwardbevelforsolidpancreaticmass
AT ishizukanaoki prospectivestudyofeusguidedtissueacquisitionwitha20gcorebiopsyneedlewithaforwardbevelforsolidpancreaticmass
AT sasahiranaoki prospectivestudyofeusguidedtissueacquisitionwitha20gcorebiopsyneedlewithaforwardbevelforsolidpancreaticmass