Cargando…

Practical Clinical Implementation of the Special Physics Consultation Process in the Re-irradiation Environment

PURPOSE: The purpose of this work is to present a practical, structured process allowing for consistent, safe radiation therapy delivery in the re-treatment environment. METHODS AND MATERIALS: A process for reirradiation is described with documentation in the form of a special physics consultation....

Descripción completa

Detalles Bibliográficos
Autores principales: Price, Robert A., Jin, Lihui, Meyer, Joshua, Chen, Lili, Lin, Teh, Eldib, Ahmed, Chen, Xiaoming, Liu, Jie, Veltchev, Iavor, Wang, Lu, Ma, Charlie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7811122/
https://www.ncbi.nlm.nih.gov/pubmed/33490729
http://dx.doi.org/10.1016/j.adro.2020.09.027
_version_ 1783637436520202240
author Price, Robert A.
Jin, Lihui
Meyer, Joshua
Chen, Lili
Lin, Teh
Eldib, Ahmed
Chen, Xiaoming
Liu, Jie
Veltchev, Iavor
Wang, Lu
Ma, Charlie
author_facet Price, Robert A.
Jin, Lihui
Meyer, Joshua
Chen, Lili
Lin, Teh
Eldib, Ahmed
Chen, Xiaoming
Liu, Jie
Veltchev, Iavor
Wang, Lu
Ma, Charlie
author_sort Price, Robert A.
collection PubMed
description PURPOSE: The purpose of this work is to present a practical, structured process allowing for consistent, safe radiation therapy delivery in the re-treatment environment. METHODS AND MATERIALS: A process for reirradiation is described with documentation in the form of a special physics consultation. Data acquisition associated with previous treatment is described from highest to lowest quality. Methods are presented for conversion to equieffective dose, as well as our departmental assumptions for tissue repair. The generation of organ-at-risk available physical dose for use in treatment planning is discussed. Results using our methods are compared with published values after conversion to biologically effective dose. Utilization of pulsed-low-dose-rate delivery is described, and data for reirradiation using these methods over the previous 5 years are presented. RESULTS: Between 2015 and 2019, the number of patients in our department requiring equieffective dose calculation has doubled. We have developed guidelines for estimation of sublethal damage repair as a function of time between treatment courses ranging from 0% for <6 months to 50% for >1 year. These guidelines were developed based on available spinal cord data because we found that 84% of organs at risk involved nerve-like tissues. The average percent repair used increased from 32% to 37% over this time period. When comparing the results obtained using our methods with published values, 99% of patients had a cumulative biologically effective dose below the limits established for acceptable myelopathy rates. Pulsed-low-dose-rate use over this period tripled with an average prescription dose of 49 Gy. CONCLUSIONS: The methods described result in safe, effective treatment in the reirradiation setting. Further correlation with patient outcomes and side effects is warranted.
format Online
Article
Text
id pubmed-7811122
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-78111222021-01-22 Practical Clinical Implementation of the Special Physics Consultation Process in the Re-irradiation Environment Price, Robert A. Jin, Lihui Meyer, Joshua Chen, Lili Lin, Teh Eldib, Ahmed Chen, Xiaoming Liu, Jie Veltchev, Iavor Wang, Lu Ma, Charlie Adv Radiat Oncol Scientific Article PURPOSE: The purpose of this work is to present a practical, structured process allowing for consistent, safe radiation therapy delivery in the re-treatment environment. METHODS AND MATERIALS: A process for reirradiation is described with documentation in the form of a special physics consultation. Data acquisition associated with previous treatment is described from highest to lowest quality. Methods are presented for conversion to equieffective dose, as well as our departmental assumptions for tissue repair. The generation of organ-at-risk available physical dose for use in treatment planning is discussed. Results using our methods are compared with published values after conversion to biologically effective dose. Utilization of pulsed-low-dose-rate delivery is described, and data for reirradiation using these methods over the previous 5 years are presented. RESULTS: Between 2015 and 2019, the number of patients in our department requiring equieffective dose calculation has doubled. We have developed guidelines for estimation of sublethal damage repair as a function of time between treatment courses ranging from 0% for <6 months to 50% for >1 year. These guidelines were developed based on available spinal cord data because we found that 84% of organs at risk involved nerve-like tissues. The average percent repair used increased from 32% to 37% over this time period. When comparing the results obtained using our methods with published values, 99% of patients had a cumulative biologically effective dose below the limits established for acceptable myelopathy rates. Pulsed-low-dose-rate use over this period tripled with an average prescription dose of 49 Gy. CONCLUSIONS: The methods described result in safe, effective treatment in the reirradiation setting. Further correlation with patient outcomes and side effects is warranted. Elsevier 2020-10-14 /pmc/articles/PMC7811122/ /pubmed/33490729 http://dx.doi.org/10.1016/j.adro.2020.09.027 Text en © 2020 The Author(s) http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Scientific Article
Price, Robert A.
Jin, Lihui
Meyer, Joshua
Chen, Lili
Lin, Teh
Eldib, Ahmed
Chen, Xiaoming
Liu, Jie
Veltchev, Iavor
Wang, Lu
Ma, Charlie
Practical Clinical Implementation of the Special Physics Consultation Process in the Re-irradiation Environment
title Practical Clinical Implementation of the Special Physics Consultation Process in the Re-irradiation Environment
title_full Practical Clinical Implementation of the Special Physics Consultation Process in the Re-irradiation Environment
title_fullStr Practical Clinical Implementation of the Special Physics Consultation Process in the Re-irradiation Environment
title_full_unstemmed Practical Clinical Implementation of the Special Physics Consultation Process in the Re-irradiation Environment
title_short Practical Clinical Implementation of the Special Physics Consultation Process in the Re-irradiation Environment
title_sort practical clinical implementation of the special physics consultation process in the re-irradiation environment
topic Scientific Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7811122/
https://www.ncbi.nlm.nih.gov/pubmed/33490729
http://dx.doi.org/10.1016/j.adro.2020.09.027
work_keys_str_mv AT priceroberta practicalclinicalimplementationofthespecialphysicsconsultationprocessinthereirradiationenvironment
AT jinlihui practicalclinicalimplementationofthespecialphysicsconsultationprocessinthereirradiationenvironment
AT meyerjoshua practicalclinicalimplementationofthespecialphysicsconsultationprocessinthereirradiationenvironment
AT chenlili practicalclinicalimplementationofthespecialphysicsconsultationprocessinthereirradiationenvironment
AT linteh practicalclinicalimplementationofthespecialphysicsconsultationprocessinthereirradiationenvironment
AT eldibahmed practicalclinicalimplementationofthespecialphysicsconsultationprocessinthereirradiationenvironment
AT chenxiaoming practicalclinicalimplementationofthespecialphysicsconsultationprocessinthereirradiationenvironment
AT liujie practicalclinicalimplementationofthespecialphysicsconsultationprocessinthereirradiationenvironment
AT veltcheviavor practicalclinicalimplementationofthespecialphysicsconsultationprocessinthereirradiationenvironment
AT wanglu practicalclinicalimplementationofthespecialphysicsconsultationprocessinthereirradiationenvironment
AT macharlie practicalclinicalimplementationofthespecialphysicsconsultationprocessinthereirradiationenvironment