Cargando…

The anatomic basis for ultrasound in the diagnosis and treatment of styloid process–related diseases

BACKGROUND: The styloid process (SP), stylohyoid ligament and lesser horn of hyoid bone together form the stylohyoid chain. Differences in the ossification degree and the connection sites of each segment of the stylohyoid chain on both sides lead to variations in the length, orientation, thickness,...

Descripción completa

Detalles Bibliográficos
Autores principales: Zang, Yirou, Chen, Shiyu, Zang, Guoli, Hu, Ming, Xu, Qing, Feng, Zhubing, Pan, Ashan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7812206/
https://www.ncbi.nlm.nih.gov/pubmed/33490178
http://dx.doi.org/10.21037/atm-20-7781
_version_ 1783637619736838144
author Zang, Yirou
Chen, Shiyu
Zang, Guoli
Hu, Ming
Xu, Qing
Feng, Zhubing
Pan, Ashan
author_facet Zang, Yirou
Chen, Shiyu
Zang, Guoli
Hu, Ming
Xu, Qing
Feng, Zhubing
Pan, Ashan
author_sort Zang, Yirou
collection PubMed
description BACKGROUND: The styloid process (SP), stylohyoid ligament and lesser horn of hyoid bone together form the stylohyoid chain. Differences in the ossification degree and the connection sites of each segment of the stylohyoid chain on both sides lead to variations in the length, orientation, thickness, and straightness of SP. The incidence of elongation of the SP, known as styloid process syndrome (SPS), is around 4%, with only 4% of patients showing elongation show symptoms. Computed tomography (CT) remains the first-choice auxiliary examination for diagnosing SPS, but its performance can be affected by a variety of factors. Ultrasound can reveal the parapharyngeal space and adjacent structures, which offer high consistency with CT findings. Here, we investigated the ultrasonographic features of the SP and its adjacent structures in normal adults and assessed the clinical utility of ultrasound assessment for SP-related diseases. METHODS: With the ramus of mandible, mastoid process, SP, and salivary gland as the anatomical landmarks, ultrasonography was conducted on the parapharyngeal space in 78 healthy adults. The scans were performed along the oblique coronal section of the ramus and the cross-sectional plane between the mastoid process and ramus to visualize the SP and its adjacent structures. The SP length, the shortest distance from the SP tip to the outer edge of tonsil (SP-tonsil distance), and the distance from SP to the internal carotid artery (SP–ICA distance) were measured. RESULTS: SP and its adjacent structures were successfully visualized on ultrasonography in all 78 subjects. The measured SP length was 2.65±0.48 cm. The SP–tonsil distance was 1.95±0.50 cm. The SP–ICA distance was 0.509±0.231 cm. The SP length and SP–tonsil distance measured by ultrasound were not significantly different from those measured by CT (P=0.071, P=0.053). Furthermore, the SP length and SP–tonsil distance measured by ultrasound were positively correlated with CT measurements (r=0.917, P=0.071; r=0.978, P=0.053, respectively). SP–tonsil distance was negatively correlated with SP length and SP inward deflection angle. CONCLUSIONS: Ultrasound can accurately reveal the shape and size of SP and its adjacent structures and thus will be helpful for the diagnosis of SP-related diseases.
format Online
Article
Text
id pubmed-7812206
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-78122062021-01-22 The anatomic basis for ultrasound in the diagnosis and treatment of styloid process–related diseases Zang, Yirou Chen, Shiyu Zang, Guoli Hu, Ming Xu, Qing Feng, Zhubing Pan, Ashan Ann Transl Med Original Article BACKGROUND: The styloid process (SP), stylohyoid ligament and lesser horn of hyoid bone together form the stylohyoid chain. Differences in the ossification degree and the connection sites of each segment of the stylohyoid chain on both sides lead to variations in the length, orientation, thickness, and straightness of SP. The incidence of elongation of the SP, known as styloid process syndrome (SPS), is around 4%, with only 4% of patients showing elongation show symptoms. Computed tomography (CT) remains the first-choice auxiliary examination for diagnosing SPS, but its performance can be affected by a variety of factors. Ultrasound can reveal the parapharyngeal space and adjacent structures, which offer high consistency with CT findings. Here, we investigated the ultrasonographic features of the SP and its adjacent structures in normal adults and assessed the clinical utility of ultrasound assessment for SP-related diseases. METHODS: With the ramus of mandible, mastoid process, SP, and salivary gland as the anatomical landmarks, ultrasonography was conducted on the parapharyngeal space in 78 healthy adults. The scans were performed along the oblique coronal section of the ramus and the cross-sectional plane between the mastoid process and ramus to visualize the SP and its adjacent structures. The SP length, the shortest distance from the SP tip to the outer edge of tonsil (SP-tonsil distance), and the distance from SP to the internal carotid artery (SP–ICA distance) were measured. RESULTS: SP and its adjacent structures were successfully visualized on ultrasonography in all 78 subjects. The measured SP length was 2.65±0.48 cm. The SP–tonsil distance was 1.95±0.50 cm. The SP–ICA distance was 0.509±0.231 cm. The SP length and SP–tonsil distance measured by ultrasound were not significantly different from those measured by CT (P=0.071, P=0.053). Furthermore, the SP length and SP–tonsil distance measured by ultrasound were positively correlated with CT measurements (r=0.917, P=0.071; r=0.978, P=0.053, respectively). SP–tonsil distance was negatively correlated with SP length and SP inward deflection angle. CONCLUSIONS: Ultrasound can accurately reveal the shape and size of SP and its adjacent structures and thus will be helpful for the diagnosis of SP-related diseases. AME Publishing Company 2020-12 /pmc/articles/PMC7812206/ /pubmed/33490178 http://dx.doi.org/10.21037/atm-20-7781 Text en 2020 Annals of Translational Medicine. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
Zang, Yirou
Chen, Shiyu
Zang, Guoli
Hu, Ming
Xu, Qing
Feng, Zhubing
Pan, Ashan
The anatomic basis for ultrasound in the diagnosis and treatment of styloid process–related diseases
title The anatomic basis for ultrasound in the diagnosis and treatment of styloid process–related diseases
title_full The anatomic basis for ultrasound in the diagnosis and treatment of styloid process–related diseases
title_fullStr The anatomic basis for ultrasound in the diagnosis and treatment of styloid process–related diseases
title_full_unstemmed The anatomic basis for ultrasound in the diagnosis and treatment of styloid process–related diseases
title_short The anatomic basis for ultrasound in the diagnosis and treatment of styloid process–related diseases
title_sort anatomic basis for ultrasound in the diagnosis and treatment of styloid process–related diseases
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7812206/
https://www.ncbi.nlm.nih.gov/pubmed/33490178
http://dx.doi.org/10.21037/atm-20-7781
work_keys_str_mv AT zangyirou theanatomicbasisforultrasoundinthediagnosisandtreatmentofstyloidprocessrelateddiseases
AT chenshiyu theanatomicbasisforultrasoundinthediagnosisandtreatmentofstyloidprocessrelateddiseases
AT zangguoli theanatomicbasisforultrasoundinthediagnosisandtreatmentofstyloidprocessrelateddiseases
AT huming theanatomicbasisforultrasoundinthediagnosisandtreatmentofstyloidprocessrelateddiseases
AT xuqing theanatomicbasisforultrasoundinthediagnosisandtreatmentofstyloidprocessrelateddiseases
AT fengzhubing theanatomicbasisforultrasoundinthediagnosisandtreatmentofstyloidprocessrelateddiseases
AT panashan theanatomicbasisforultrasoundinthediagnosisandtreatmentofstyloidprocessrelateddiseases
AT zangyirou anatomicbasisforultrasoundinthediagnosisandtreatmentofstyloidprocessrelateddiseases
AT chenshiyu anatomicbasisforultrasoundinthediagnosisandtreatmentofstyloidprocessrelateddiseases
AT zangguoli anatomicbasisforultrasoundinthediagnosisandtreatmentofstyloidprocessrelateddiseases
AT huming anatomicbasisforultrasoundinthediagnosisandtreatmentofstyloidprocessrelateddiseases
AT xuqing anatomicbasisforultrasoundinthediagnosisandtreatmentofstyloidprocessrelateddiseases
AT fengzhubing anatomicbasisforultrasoundinthediagnosisandtreatmentofstyloidprocessrelateddiseases
AT panashan anatomicbasisforultrasoundinthediagnosisandtreatmentofstyloidprocessrelateddiseases