Cargando…
The use of a 3D-printed individualized navigation template to assist in the anatomical reconstruction surgery of the anterior cruciate ligament
BACKGROUND: To explore the location accuracy and early clinical outcomes of using a 3D-printed individualized navigation template to assist in the reconstruction of the anterior cruciate ligament (ACL). METHODS: A single center randomized control study was conducted. Patients with ACL injury were tr...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AME Publishing Company
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7812217/ https://www.ncbi.nlm.nih.gov/pubmed/33490168 http://dx.doi.org/10.21037/atm-20-7515 |
_version_ | 1783637622371909632 |
---|---|
author | Liu, Dejian Li, Yanlin Li, Tao Yu, Yang Cai, Guofeng Yang, Guiran Wang, Guoliang |
author_facet | Liu, Dejian Li, Yanlin Li, Tao Yu, Yang Cai, Guofeng Yang, Guiran Wang, Guoliang |
author_sort | Liu, Dejian |
collection | PubMed |
description | BACKGROUND: To explore the location accuracy and early clinical outcomes of using a 3D-printed individualized navigation template to assist in the reconstruction of the anterior cruciate ligament (ACL). METHODS: A single center randomized control study was conducted. Patients with ACL injury were treated with a conventional operation or an operation assisted by a 3D-printed individualized navigation template (the 3D group). The primary endpoint was the accuracy of the actual reconstruction compared with the planned position. RESULTS: There were 20 and 23 participants in the conventional group and the 3D group, respectively. There were no differences in the bone tunnel position between the actual postoperative position and the preoperative design in the 3D group (P>0.05). Compared with the 3D group, the positioning of the femoral tunnel was more inferior and shallower in the conventional group (P<0.05). The position of the tibia tunnel was closer to the anterior and medial edge of the tibial platform in the conventional group compared to the 3D group (P<0.05). The intraoperative positioning time was shorter in the 3D group than in the conventional group (3.3±1.0 vs. 5.9±1.8 minutes, P<0.001). The Lysholm and International Knee Documentation Committee scores did not differ between the two groups (P>0.05 for both), and all patients improved after surgery (P<0.001). CONCLUSIONS: The 3D-printed individualized navigation template showed good location accuracy and resulted in reduced intraoperative positioning time compared to the traditional method for ACL reconstruction. |
format | Online Article Text |
id | pubmed-7812217 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | AME Publishing Company |
record_format | MEDLINE/PubMed |
spelling | pubmed-78122172021-01-22 The use of a 3D-printed individualized navigation template to assist in the anatomical reconstruction surgery of the anterior cruciate ligament Liu, Dejian Li, Yanlin Li, Tao Yu, Yang Cai, Guofeng Yang, Guiran Wang, Guoliang Ann Transl Med Original Article BACKGROUND: To explore the location accuracy and early clinical outcomes of using a 3D-printed individualized navigation template to assist in the reconstruction of the anterior cruciate ligament (ACL). METHODS: A single center randomized control study was conducted. Patients with ACL injury were treated with a conventional operation or an operation assisted by a 3D-printed individualized navigation template (the 3D group). The primary endpoint was the accuracy of the actual reconstruction compared with the planned position. RESULTS: There were 20 and 23 participants in the conventional group and the 3D group, respectively. There were no differences in the bone tunnel position between the actual postoperative position and the preoperative design in the 3D group (P>0.05). Compared with the 3D group, the positioning of the femoral tunnel was more inferior and shallower in the conventional group (P<0.05). The position of the tibia tunnel was closer to the anterior and medial edge of the tibial platform in the conventional group compared to the 3D group (P<0.05). The intraoperative positioning time was shorter in the 3D group than in the conventional group (3.3±1.0 vs. 5.9±1.8 minutes, P<0.001). The Lysholm and International Knee Documentation Committee scores did not differ between the two groups (P>0.05 for both), and all patients improved after surgery (P<0.001). CONCLUSIONS: The 3D-printed individualized navigation template showed good location accuracy and resulted in reduced intraoperative positioning time compared to the traditional method for ACL reconstruction. AME Publishing Company 2020-12 /pmc/articles/PMC7812217/ /pubmed/33490168 http://dx.doi.org/10.21037/atm-20-7515 Text en 2020 Annals of Translational Medicine. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) . |
spellingShingle | Original Article Liu, Dejian Li, Yanlin Li, Tao Yu, Yang Cai, Guofeng Yang, Guiran Wang, Guoliang The use of a 3D-printed individualized navigation template to assist in the anatomical reconstruction surgery of the anterior cruciate ligament |
title | The use of a 3D-printed individualized navigation template to assist in the anatomical reconstruction surgery of the anterior cruciate ligament |
title_full | The use of a 3D-printed individualized navigation template to assist in the anatomical reconstruction surgery of the anterior cruciate ligament |
title_fullStr | The use of a 3D-printed individualized navigation template to assist in the anatomical reconstruction surgery of the anterior cruciate ligament |
title_full_unstemmed | The use of a 3D-printed individualized navigation template to assist in the anatomical reconstruction surgery of the anterior cruciate ligament |
title_short | The use of a 3D-printed individualized navigation template to assist in the anatomical reconstruction surgery of the anterior cruciate ligament |
title_sort | use of a 3d-printed individualized navigation template to assist in the anatomical reconstruction surgery of the anterior cruciate ligament |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7812217/ https://www.ncbi.nlm.nih.gov/pubmed/33490168 http://dx.doi.org/10.21037/atm-20-7515 |
work_keys_str_mv | AT liudejian theuseofa3dprintedindividualizednavigationtemplatetoassistintheanatomicalreconstructionsurgeryoftheanteriorcruciateligament AT liyanlin theuseofa3dprintedindividualizednavigationtemplatetoassistintheanatomicalreconstructionsurgeryoftheanteriorcruciateligament AT litao theuseofa3dprintedindividualizednavigationtemplatetoassistintheanatomicalreconstructionsurgeryoftheanteriorcruciateligament AT yuyang theuseofa3dprintedindividualizednavigationtemplatetoassistintheanatomicalreconstructionsurgeryoftheanteriorcruciateligament AT caiguofeng theuseofa3dprintedindividualizednavigationtemplatetoassistintheanatomicalreconstructionsurgeryoftheanteriorcruciateligament AT yangguiran theuseofa3dprintedindividualizednavigationtemplatetoassistintheanatomicalreconstructionsurgeryoftheanteriorcruciateligament AT wangguoliang theuseofa3dprintedindividualizednavigationtemplatetoassistintheanatomicalreconstructionsurgeryoftheanteriorcruciateligament AT liudejian useofa3dprintedindividualizednavigationtemplatetoassistintheanatomicalreconstructionsurgeryoftheanteriorcruciateligament AT liyanlin useofa3dprintedindividualizednavigationtemplatetoassistintheanatomicalreconstructionsurgeryoftheanteriorcruciateligament AT litao useofa3dprintedindividualizednavigationtemplatetoassistintheanatomicalreconstructionsurgeryoftheanteriorcruciateligament AT yuyang useofa3dprintedindividualizednavigationtemplatetoassistintheanatomicalreconstructionsurgeryoftheanteriorcruciateligament AT caiguofeng useofa3dprintedindividualizednavigationtemplatetoassistintheanatomicalreconstructionsurgeryoftheanteriorcruciateligament AT yangguiran useofa3dprintedindividualizednavigationtemplatetoassistintheanatomicalreconstructionsurgeryoftheanteriorcruciateligament AT wangguoliang useofa3dprintedindividualizednavigationtemplatetoassistintheanatomicalreconstructionsurgeryoftheanteriorcruciateligament |