Cargando…

Strategy of pacemaker and electrode replacement for superior vena cava stenosis

Cardiac implantable devices are commonly used for superior vena cava stenosis, but there have been few reports of electrode replacement in the stenosed superior vena cava. A 73-year-old man was diagnosed with second-degree type II atrioventricular block and a permanent dual-chamber, rate-modulated p...

Descripción completa

Detalles Bibliográficos
Autores principales: Zheng, Zhi-Peng, Zhang, Wei, Zeng, Zhi-huan, Zheng, Jian-yi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7812412/
https://www.ncbi.nlm.nih.gov/pubmed/33445982
http://dx.doi.org/10.1177/0300060520945170
_version_ 1783637665202044928
author Zheng, Zhi-Peng
Zhang, Wei
Zeng, Zhi-huan
Zheng, Jian-yi
author_facet Zheng, Zhi-Peng
Zhang, Wei
Zeng, Zhi-huan
Zheng, Jian-yi
author_sort Zheng, Zhi-Peng
collection PubMed
description Cardiac implantable devices are commonly used for superior vena cava stenosis, but there have been few reports of electrode replacement in the stenosed superior vena cava. A 73-year-old man was diagnosed with second-degree type II atrioventricular block and a permanent dual-chamber, rate-modulated pacing pacemaker was implanted 10 years previously. Because of depletion of the pacemaker battery and an increase in the ventricular pacing threshold, replacement of the pacemaker and ventricular electrode was required. During the operation, we found that the patient had severe superior vena cava stenosis on angiography, and this caused obstruction when a common guidewire was used to pass through the superior vena cava. After attempting various methods, we successfully passed through the vascular stenosis with a super slide guidewire and a long sheath, and completed replacement of the pacemaker and ventricular electrode. We summarize the related literature of superior vena cava stenosis related to a cardiac implantable device, and discuss the replacement strategy of this complication and other treatment options.
format Online
Article
Text
id pubmed-7812412
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-78124122021-01-26 Strategy of pacemaker and electrode replacement for superior vena cava stenosis Zheng, Zhi-Peng Zhang, Wei Zeng, Zhi-huan Zheng, Jian-yi J Int Med Res Case Report Cardiac implantable devices are commonly used for superior vena cava stenosis, but there have been few reports of electrode replacement in the stenosed superior vena cava. A 73-year-old man was diagnosed with second-degree type II atrioventricular block and a permanent dual-chamber, rate-modulated pacing pacemaker was implanted 10 years previously. Because of depletion of the pacemaker battery and an increase in the ventricular pacing threshold, replacement of the pacemaker and ventricular electrode was required. During the operation, we found that the patient had severe superior vena cava stenosis on angiography, and this caused obstruction when a common guidewire was used to pass through the superior vena cava. After attempting various methods, we successfully passed through the vascular stenosis with a super slide guidewire and a long sheath, and completed replacement of the pacemaker and ventricular electrode. We summarize the related literature of superior vena cava stenosis related to a cardiac implantable device, and discuss the replacement strategy of this complication and other treatment options. SAGE Publications 2021-01-14 /pmc/articles/PMC7812412/ /pubmed/33445982 http://dx.doi.org/10.1177/0300060520945170 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc/4.0/ Creative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Case Report
Zheng, Zhi-Peng
Zhang, Wei
Zeng, Zhi-huan
Zheng, Jian-yi
Strategy of pacemaker and electrode replacement for superior vena cava stenosis
title Strategy of pacemaker and electrode replacement for superior vena cava stenosis
title_full Strategy of pacemaker and electrode replacement for superior vena cava stenosis
title_fullStr Strategy of pacemaker and electrode replacement for superior vena cava stenosis
title_full_unstemmed Strategy of pacemaker and electrode replacement for superior vena cava stenosis
title_short Strategy of pacemaker and electrode replacement for superior vena cava stenosis
title_sort strategy of pacemaker and electrode replacement for superior vena cava stenosis
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7812412/
https://www.ncbi.nlm.nih.gov/pubmed/33445982
http://dx.doi.org/10.1177/0300060520945170
work_keys_str_mv AT zhengzhipeng strategyofpacemakerandelectrodereplacementforsuperiorvenacavastenosis
AT zhangwei strategyofpacemakerandelectrodereplacementforsuperiorvenacavastenosis
AT zengzhihuan strategyofpacemakerandelectrodereplacementforsuperiorvenacavastenosis
AT zhengjianyi strategyofpacemakerandelectrodereplacementforsuperiorvenacavastenosis