Cargando…
Temporal evolution of neurovascular coupling recovery following moderate‐ and high‐intensity exercise
PURPOSE: Studies examining neurovascular coupling (NVC) require participants to refrain from exercise for 12–24 hours. However, there is a paucity of empirical evidence for this restriction. The objectives for this study were to delineate the time‐course recovery of NVC metrics following exercise an...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7814491/ https://www.ncbi.nlm.nih.gov/pubmed/33463899 http://dx.doi.org/10.14814/phy2.14695 |
Sumario: | PURPOSE: Studies examining neurovascular coupling (NVC) require participants to refrain from exercise for 12–24 hours. However, there is a paucity of empirical evidence for this restriction. The objectives for this study were to delineate the time‐course recovery of NVC metrics following exercise and establish the NVC within‐ and between‐day reliability. METHODS: Nine participants completed a complex visual search paradigm to assess NVC via transcranial Doppler ultrasound of the posterior cerebral artery blood velocity (PCA). Measurements were performed prior to and throughout the 8‐hour recovery period following three randomized conditions: 45 minutes of moderate‐intensity exercise (at 50% heart‐rate reserve), 30 minutes high‐intensity intervals (10, 1‐minute intervals at 85% heart‐rate reserve), and control (30 minutes quiet rest). In each condition, baseline measures were collected at 8:00am with serial follow‐ups at hours zero, one, two, four, six, and eight. RESULTS: Area‐under‐the‐curve and time‐to‐peak PCA velocity during the visual search were attenuated at hour zero following high‐intensity intervals (all p < 0.05); however, these NVC metrics recovered at hour one (all p > 0.13). Conversely, baseline PCA velocity, peak PCA velocity, and the relative percent increase were not different following high‐intensity intervals compared to baseline (all p > 0.26). No NVC metrics differed from baseline following both moderate exercise and control conditions (all p > 0.24). The majority of the NVC parameters demonstrated high levels of reliability (intraclass correlation coefficient: >0.90). CONCLUSION: Future NVC assessments can take place a minimum of one hour following exercise. Moreover, all metrics did not change across the control condition, therefore future studies using this methodology can reliably quantify NVC between 8:00am and 7:00 pm. |
---|