Cargando…
Utilization of serum D-dimer assays prior to computed tomography pulmonary angiography scans in the diagnosis of pulmonary embolism among emergency department physicians: a retrospective observational study
BACKGROUND: A variety of evidence-based algorithms and decision rules using D-Dimer testing have been proposed as instruments to allow physicians to safely rule out a pulmonary embolism (PE) in low-risk patients. OBJECTIVE: To describe the prevalence of D-Dimer utilization among emergency department...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7814629/ https://www.ncbi.nlm.nih.gov/pubmed/33468044 http://dx.doi.org/10.1186/s12873-021-00401-x |
Sumario: | BACKGROUND: A variety of evidence-based algorithms and decision rules using D-Dimer testing have been proposed as instruments to allow physicians to safely rule out a pulmonary embolism (PE) in low-risk patients. OBJECTIVE: To describe the prevalence of D-Dimer utilization among emergency department (ED) physicians and its impact on positive yields and utilization rates of Computed Tomography Pulmonary Angiography (CTPA). METHODS: Data was collected on all CTPA studies ordered by ED physicians at three sites during a 2-year period. Using a chi-square test, we compared the diagnostic yield for those patients who had a D-Dimer prior to their CTPA and those who did not. Secondary analysis was done to examine the impact of D-Dimer testing prior to CTPA on individual physician diagnostic yield or utilization rate. RESULTS: A total of 2811 CTPAs were included in the analysis. Of these, 964 CTPAs (34.3%) were ordered without a D-Dimer, and 343 (18.7%) underwent a CTPA despite a negative D-Dimer. Those CTPAs preceded by a D-Dimer showed no significant difference in positive yields when compared to those ordered without a D-Dimer (9.9% versus 11.3%, p = 0.26). At the individual physician level, no statistically significant relationship was found between D-Dimer utilization and CTPA utilization rate or diagnostic yield. CONCLUSION: This study provides evidence of suboptimal adherence to guidelines in terms of D-Dimer screening prior to CTPA, and forgoing CTPAs in patients with negative D-Dimers. However, the lack of a positive impact of D-Dimer testing on either CTPA diagnostic yield or utilization rate is indicative of issues relating to the high false-positive rates associated with D-Dimer screening. |
---|