Cargando…

Evaluation of the effect of ultraviolet light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin to the cobalt-chromium retentive minor connector: An in vitro study

AIM: The aim of this study is to evaluate the efficacy of new material ultraviolet (UV) light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin (Polymethylmethacrylate (PMMA)) to cobalt-chromium (Co-Cr) retentive minor connector. SETTING AND DESIGN: Compar...

Descripción completa

Detalles Bibliográficos
Autores principales: Kumthekar, Minal Sanjay, Tewary, Shivsagar, Sanyal, Pronob Kumar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7814690/
https://www.ncbi.nlm.nih.gov/pubmed/33487967
http://dx.doi.org/10.4103/jips.jips_85_20
_version_ 1783638105298829312
author Kumthekar, Minal Sanjay
Tewary, Shivsagar
Sanyal, Pronob Kumar
author_facet Kumthekar, Minal Sanjay
Tewary, Shivsagar
Sanyal, Pronob Kumar
author_sort Kumthekar, Minal Sanjay
collection PubMed
description AIM: The aim of this study is to evaluate the efficacy of new material ultraviolet (UV) light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin (Polymethylmethacrylate (PMMA)) to cobalt-chromium (Co-Cr) retentive minor connector. SETTING AND DESIGN: Comparative evaluation- In-vitro study. MATERIALS AND METHODS: Sixty samples of Co-Cr plates mimicking minor connectors were fabricated. Thirty samples were coated with new material UV light polymerized clear adhesive and cured under UV light source for 10 min. In gun-metal flask, metal plates were placed in the lower compartment over it. Heat cure acrylic resin was packed in the dough stage with the help of clamps and processed according to the manufacturer's instructions. Samples were kept in artificial saliva for 90 days. Shear and tensile bond strengths were calculated of each sample with a Universal testing machine, and results were statistically analyzed. Type of bond failure was observed for each sample under stereomicroscope. STATISTICAL ANALYSIS USED: Unpaired t test. RESULTS: Tensile bond strength, as well as shear bond strength, showed that 0.93 N and 1.64 N respectively for without application of new adhesive was more as compared to that of samples with the application of new adhesive which is 0.75 N and 1.54 N respectively. Bond failure was found to be an adhesive failure in resin–metal interface. CONCLUSIONS: Excellent bonding seen between the new adhesive and acrylic interface but limited effect on the metal interface. To increase bond strength between metal and resin interface, some surface treatment with the metal surface is needed to increase the bonding of the new adhesive to the metal surface.
format Online
Article
Text
id pubmed-7814690
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-78146902021-10-01 Evaluation of the effect of ultraviolet light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin to the cobalt-chromium retentive minor connector: An in vitro study Kumthekar, Minal Sanjay Tewary, Shivsagar Sanyal, Pronob Kumar J Indian Prosthodont Soc Original Article AIM: The aim of this study is to evaluate the efficacy of new material ultraviolet (UV) light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin (Polymethylmethacrylate (PMMA)) to cobalt-chromium (Co-Cr) retentive minor connector. SETTING AND DESIGN: Comparative evaluation- In-vitro study. MATERIALS AND METHODS: Sixty samples of Co-Cr plates mimicking minor connectors were fabricated. Thirty samples were coated with new material UV light polymerized clear adhesive and cured under UV light source for 10 min. In gun-metal flask, metal plates were placed in the lower compartment over it. Heat cure acrylic resin was packed in the dough stage with the help of clamps and processed according to the manufacturer's instructions. Samples were kept in artificial saliva for 90 days. Shear and tensile bond strengths were calculated of each sample with a Universal testing machine, and results were statistically analyzed. Type of bond failure was observed for each sample under stereomicroscope. STATISTICAL ANALYSIS USED: Unpaired t test. RESULTS: Tensile bond strength, as well as shear bond strength, showed that 0.93 N and 1.64 N respectively for without application of new adhesive was more as compared to that of samples with the application of new adhesive which is 0.75 N and 1.54 N respectively. Bond failure was found to be an adhesive failure in resin–metal interface. CONCLUSIONS: Excellent bonding seen between the new adhesive and acrylic interface but limited effect on the metal interface. To increase bond strength between metal and resin interface, some surface treatment with the metal surface is needed to increase the bonding of the new adhesive to the metal surface. Wolters Kluwer - Medknow 2020 2020-10-08 /pmc/articles/PMC7814690/ /pubmed/33487967 http://dx.doi.org/10.4103/jips.jips_85_20 Text en Copyright: © 2020 The Journal of Indian Prosthodontic Society http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Kumthekar, Minal Sanjay
Tewary, Shivsagar
Sanyal, Pronob Kumar
Evaluation of the effect of ultraviolet light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin to the cobalt-chromium retentive minor connector: An in vitro study
title Evaluation of the effect of ultraviolet light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin to the cobalt-chromium retentive minor connector: An in vitro study
title_full Evaluation of the effect of ultraviolet light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin to the cobalt-chromium retentive minor connector: An in vitro study
title_fullStr Evaluation of the effect of ultraviolet light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin to the cobalt-chromium retentive minor connector: An in vitro study
title_full_unstemmed Evaluation of the effect of ultraviolet light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin to the cobalt-chromium retentive minor connector: An in vitro study
title_short Evaluation of the effect of ultraviolet light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin to the cobalt-chromium retentive minor connector: An in vitro study
title_sort evaluation of the effect of ultraviolet light polymerized clear adhesive on shear and tensile bond strength of heat cure denture base resin to the cobalt-chromium retentive minor connector: an in vitro study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7814690/
https://www.ncbi.nlm.nih.gov/pubmed/33487967
http://dx.doi.org/10.4103/jips.jips_85_20
work_keys_str_mv AT kumthekarminalsanjay evaluationoftheeffectofultravioletlightpolymerizedclearadhesiveonshearandtensilebondstrengthofheatcuredenturebaseresintothecobaltchromiumretentiveminorconnectoraninvitrostudy
AT tewaryshivsagar evaluationoftheeffectofultravioletlightpolymerizedclearadhesiveonshearandtensilebondstrengthofheatcuredenturebaseresintothecobaltchromiumretentiveminorconnectoraninvitrostudy
AT sanyalpronobkumar evaluationoftheeffectofultravioletlightpolymerizedclearadhesiveonshearandtensilebondstrengthofheatcuredenturebaseresintothecobaltchromiumretentiveminorconnectoraninvitrostudy