Cargando…
Classification of Stereo-EEG Contacts in White Matter vs. Gray Matter Using Recorded Activity
For epileptic patients requiring resective surgery, a modality called stereo-electroencephalography (SEEG) may be used to monitor the patient's brain signals to help identify epileptogenic regions that generate and propagate seizures. SEEG involves the insertion of multiple depth electrodes int...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7815703/ https://www.ncbi.nlm.nih.gov/pubmed/33488500 http://dx.doi.org/10.3389/fneur.2020.605696 |
_version_ | 1783638287653535744 |
---|---|
author | Greene, Patrick Li, Adam González-Martínez, Jorge Sarma, Sridevi V. |
author_facet | Greene, Patrick Li, Adam González-Martínez, Jorge Sarma, Sridevi V. |
author_sort | Greene, Patrick |
collection | PubMed |
description | For epileptic patients requiring resective surgery, a modality called stereo-electroencephalography (SEEG) may be used to monitor the patient's brain signals to help identify epileptogenic regions that generate and propagate seizures. SEEG involves the insertion of multiple depth electrodes into the patient's brain, each with 10 or more recording contacts along its length. However, a significant fraction (≈ 30% or more) of the contacts typically reside in white matter or other areas of the brain which can not be epileptogenic themselves. Thus, an important step in the analysis of SEEG recordings is distinguishing between electrode contacts which reside in gray matter vs. those that do not. MRI images overlaid with CT scans are currently used for this task, but they take significant amounts of time to manually annotate, and even then it may be difficult to determine the status of some contacts. In this paper we present a fast, automated method for classifying contacts in gray vs. white matter based only on the recorded signal and relative contact depth. We observe that bipolar referenced contacts in white matter have less power in all frequencies below 150 Hz than contacts in gray matter, which we use in a Bayesian classifier to attain an average area under the receiver operating characteristic curve of 0.85 ± 0.079 (SD) across 29 patients. Because our method gives a probability for each contact rather than a hard labeling, and uses a feature of the recorded signal that has direct clinical relevance, it can be useful to supplement decision-making on difficult to classify contacts or as a rapid, first-pass filter when choosing subsets of contacts from which to save recordings. |
format | Online Article Text |
id | pubmed-7815703 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-78157032021-01-21 Classification of Stereo-EEG Contacts in White Matter vs. Gray Matter Using Recorded Activity Greene, Patrick Li, Adam González-Martínez, Jorge Sarma, Sridevi V. Front Neurol Neurology For epileptic patients requiring resective surgery, a modality called stereo-electroencephalography (SEEG) may be used to monitor the patient's brain signals to help identify epileptogenic regions that generate and propagate seizures. SEEG involves the insertion of multiple depth electrodes into the patient's brain, each with 10 or more recording contacts along its length. However, a significant fraction (≈ 30% or more) of the contacts typically reside in white matter or other areas of the brain which can not be epileptogenic themselves. Thus, an important step in the analysis of SEEG recordings is distinguishing between electrode contacts which reside in gray matter vs. those that do not. MRI images overlaid with CT scans are currently used for this task, but they take significant amounts of time to manually annotate, and even then it may be difficult to determine the status of some contacts. In this paper we present a fast, automated method for classifying contacts in gray vs. white matter based only on the recorded signal and relative contact depth. We observe that bipolar referenced contacts in white matter have less power in all frequencies below 150 Hz than contacts in gray matter, which we use in a Bayesian classifier to attain an average area under the receiver operating characteristic curve of 0.85 ± 0.079 (SD) across 29 patients. Because our method gives a probability for each contact rather than a hard labeling, and uses a feature of the recorded signal that has direct clinical relevance, it can be useful to supplement decision-making on difficult to classify contacts or as a rapid, first-pass filter when choosing subsets of contacts from which to save recordings. Frontiers Media S.A. 2021-01-06 /pmc/articles/PMC7815703/ /pubmed/33488500 http://dx.doi.org/10.3389/fneur.2020.605696 Text en Copyright © 2021 Greene, Li, González-Martínez and Sarma. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Neurology Greene, Patrick Li, Adam González-Martínez, Jorge Sarma, Sridevi V. Classification of Stereo-EEG Contacts in White Matter vs. Gray Matter Using Recorded Activity |
title | Classification of Stereo-EEG Contacts in White Matter vs. Gray Matter Using Recorded Activity |
title_full | Classification of Stereo-EEG Contacts in White Matter vs. Gray Matter Using Recorded Activity |
title_fullStr | Classification of Stereo-EEG Contacts in White Matter vs. Gray Matter Using Recorded Activity |
title_full_unstemmed | Classification of Stereo-EEG Contacts in White Matter vs. Gray Matter Using Recorded Activity |
title_short | Classification of Stereo-EEG Contacts in White Matter vs. Gray Matter Using Recorded Activity |
title_sort | classification of stereo-eeg contacts in white matter vs. gray matter using recorded activity |
topic | Neurology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7815703/ https://www.ncbi.nlm.nih.gov/pubmed/33488500 http://dx.doi.org/10.3389/fneur.2020.605696 |
work_keys_str_mv | AT greenepatrick classificationofstereoeegcontactsinwhitemattervsgraymatterusingrecordedactivity AT liadam classificationofstereoeegcontactsinwhitemattervsgraymatterusingrecordedactivity AT gonzalezmartinezjorge classificationofstereoeegcontactsinwhitemattervsgraymatterusingrecordedactivity AT sarmasrideviv classificationofstereoeegcontactsinwhitemattervsgraymatterusingrecordedactivity |