Cargando…

Classification of Stereo-EEG Contacts in White Matter vs. Gray Matter Using Recorded Activity

For epileptic patients requiring resective surgery, a modality called stereo-electroencephalography (SEEG) may be used to monitor the patient's brain signals to help identify epileptogenic regions that generate and propagate seizures. SEEG involves the insertion of multiple depth electrodes int...

Descripción completa

Detalles Bibliográficos
Autores principales: Greene, Patrick, Li, Adam, González-Martínez, Jorge, Sarma, Sridevi V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7815703/
https://www.ncbi.nlm.nih.gov/pubmed/33488500
http://dx.doi.org/10.3389/fneur.2020.605696
_version_ 1783638287653535744
author Greene, Patrick
Li, Adam
González-Martínez, Jorge
Sarma, Sridevi V.
author_facet Greene, Patrick
Li, Adam
González-Martínez, Jorge
Sarma, Sridevi V.
author_sort Greene, Patrick
collection PubMed
description For epileptic patients requiring resective surgery, a modality called stereo-electroencephalography (SEEG) may be used to monitor the patient's brain signals to help identify epileptogenic regions that generate and propagate seizures. SEEG involves the insertion of multiple depth electrodes into the patient's brain, each with 10 or more recording contacts along its length. However, a significant fraction (≈ 30% or more) of the contacts typically reside in white matter or other areas of the brain which can not be epileptogenic themselves. Thus, an important step in the analysis of SEEG recordings is distinguishing between electrode contacts which reside in gray matter vs. those that do not. MRI images overlaid with CT scans are currently used for this task, but they take significant amounts of time to manually annotate, and even then it may be difficult to determine the status of some contacts. In this paper we present a fast, automated method for classifying contacts in gray vs. white matter based only on the recorded signal and relative contact depth. We observe that bipolar referenced contacts in white matter have less power in all frequencies below 150 Hz than contacts in gray matter, which we use in a Bayesian classifier to attain an average area under the receiver operating characteristic curve of 0.85 ± 0.079 (SD) across 29 patients. Because our method gives a probability for each contact rather than a hard labeling, and uses a feature of the recorded signal that has direct clinical relevance, it can be useful to supplement decision-making on difficult to classify contacts or as a rapid, first-pass filter when choosing subsets of contacts from which to save recordings.
format Online
Article
Text
id pubmed-7815703
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-78157032021-01-21 Classification of Stereo-EEG Contacts in White Matter vs. Gray Matter Using Recorded Activity Greene, Patrick Li, Adam González-Martínez, Jorge Sarma, Sridevi V. Front Neurol Neurology For epileptic patients requiring resective surgery, a modality called stereo-electroencephalography (SEEG) may be used to monitor the patient's brain signals to help identify epileptogenic regions that generate and propagate seizures. SEEG involves the insertion of multiple depth electrodes into the patient's brain, each with 10 or more recording contacts along its length. However, a significant fraction (≈ 30% or more) of the contacts typically reside in white matter or other areas of the brain which can not be epileptogenic themselves. Thus, an important step in the analysis of SEEG recordings is distinguishing between electrode contacts which reside in gray matter vs. those that do not. MRI images overlaid with CT scans are currently used for this task, but they take significant amounts of time to manually annotate, and even then it may be difficult to determine the status of some contacts. In this paper we present a fast, automated method for classifying contacts in gray vs. white matter based only on the recorded signal and relative contact depth. We observe that bipolar referenced contacts in white matter have less power in all frequencies below 150 Hz than contacts in gray matter, which we use in a Bayesian classifier to attain an average area under the receiver operating characteristic curve of 0.85 ± 0.079 (SD) across 29 patients. Because our method gives a probability for each contact rather than a hard labeling, and uses a feature of the recorded signal that has direct clinical relevance, it can be useful to supplement decision-making on difficult to classify contacts or as a rapid, first-pass filter when choosing subsets of contacts from which to save recordings. Frontiers Media S.A. 2021-01-06 /pmc/articles/PMC7815703/ /pubmed/33488500 http://dx.doi.org/10.3389/fneur.2020.605696 Text en Copyright © 2021 Greene, Li, González-Martínez and Sarma. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neurology
Greene, Patrick
Li, Adam
González-Martínez, Jorge
Sarma, Sridevi V.
Classification of Stereo-EEG Contacts in White Matter vs. Gray Matter Using Recorded Activity
title Classification of Stereo-EEG Contacts in White Matter vs. Gray Matter Using Recorded Activity
title_full Classification of Stereo-EEG Contacts in White Matter vs. Gray Matter Using Recorded Activity
title_fullStr Classification of Stereo-EEG Contacts in White Matter vs. Gray Matter Using Recorded Activity
title_full_unstemmed Classification of Stereo-EEG Contacts in White Matter vs. Gray Matter Using Recorded Activity
title_short Classification of Stereo-EEG Contacts in White Matter vs. Gray Matter Using Recorded Activity
title_sort classification of stereo-eeg contacts in white matter vs. gray matter using recorded activity
topic Neurology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7815703/
https://www.ncbi.nlm.nih.gov/pubmed/33488500
http://dx.doi.org/10.3389/fneur.2020.605696
work_keys_str_mv AT greenepatrick classificationofstereoeegcontactsinwhitemattervsgraymatterusingrecordedactivity
AT liadam classificationofstereoeegcontactsinwhitemattervsgraymatterusingrecordedactivity
AT gonzalezmartinezjorge classificationofstereoeegcontactsinwhitemattervsgraymatterusingrecordedactivity
AT sarmasrideviv classificationofstereoeegcontactsinwhitemattervsgraymatterusingrecordedactivity