Cargando…

Clinical feasibility of longitudinal lateral ventricular volume measurements on T2-FLAIR across MRI scanner changes

BACKGROUND: Greater brain atrophy is associated with disability progression (DP) in patients with multiple sclerosis (PwMS). However, methodological challenges limit its routine clinical use. OBJECTIVE: To determine the feasibility of atrophy measures as markers of DP in PwMS scanned across differen...

Descripción completa

Detalles Bibliográficos
Autores principales: Jakimovski, Dejan, Zivadinov, Robert, Bergsland, Niels, Ramasamy, Deepa P., Hagemeier, Jesper, Genovese, Antonia Valentina, Hojnacki, David, Weinstock-Guttman, Bianca, Dwyer, Michael G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7816007/
https://www.ncbi.nlm.nih.gov/pubmed/33472143
http://dx.doi.org/10.1016/j.nicl.2020.102554
_version_ 1783638353946607616
author Jakimovski, Dejan
Zivadinov, Robert
Bergsland, Niels
Ramasamy, Deepa P.
Hagemeier, Jesper
Genovese, Antonia Valentina
Hojnacki, David
Weinstock-Guttman, Bianca
Dwyer, Michael G.
author_facet Jakimovski, Dejan
Zivadinov, Robert
Bergsland, Niels
Ramasamy, Deepa P.
Hagemeier, Jesper
Genovese, Antonia Valentina
Hojnacki, David
Weinstock-Guttman, Bianca
Dwyer, Michael G.
author_sort Jakimovski, Dejan
collection PubMed
description BACKGROUND: Greater brain atrophy is associated with disability progression (DP) in patients with multiple sclerosis (PwMS). However, methodological challenges limit its routine clinical use. OBJECTIVE: To determine the feasibility of atrophy measures as markers of DP in PwMS scanned across different MRI field strengths. METHODS: A total of 980 PwMS were scanned on either 1.5 T or 3.0 T MRI scanners. Demographic and clinical data were retrospectively collected, and the presence of DP was determined according to standard clinical trial criteria. Lateral ventricular volume (LVV) change was measured with the NeuroSTREAM technique on clinical routine T2-FLAIR images. Percent brain volume change (PBVC) was measured using SIENA and ventricular cerebrospinal fluid (vCSF) % change was measured using VIENA and SIENAX algorithms on 3D T1-weighted images (WI). Stable vs. DP PwMS were compared using analysis of covariance (ANCOVA). Mixed modeling determined the effect of MRI scanner change on MRI-derived atrophy measures. RESULTS: Longitudinal LVV analysis was successful in all PwMS. SIENA-based PBVC and VIENA-based changes failed in 37.6% of cases, while SIENAX-based vCSF failed in 12.9% of cases. PwMS with DP (n = 241) had significantly greater absolute (20.9% vs. 8.7%, d = 0.66, p < 0.001) and annualized LVV % change (4.1% vs. 2.3%, d = 0.27, p < 0.001) when compared to stable PwMS (n = 739). In subjects with both analyses available, both 3D-T1 and T2-FLAIR-based analyses differentiated PwMS with DP (n = 149). However, only NeuroSTREAM and VIENA-based LVV/vCSF were able to show greater atrophy in PwMS that were scanned on different scanners. PBVC and SIENAX-based vCSF % changes were significantly affected by scanner change (Beta = −0.16, t-statistics = −2.133, p = 0.033 and Beta = −2.08, t-statistics = −4.084, p < 0.001), whereas no MRI scanner change effects on NeuroSTREAM-based PLVVC and VIENA-based vCSF % change were noted. CONCLUSIONS: LVV-based atrophy on T2-FLAIR is a clinically relevant measure in spite of MRI scanner changes and mild disability levels.
format Online
Article
Text
id pubmed-7816007
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-78160072021-01-27 Clinical feasibility of longitudinal lateral ventricular volume measurements on T2-FLAIR across MRI scanner changes Jakimovski, Dejan Zivadinov, Robert Bergsland, Niels Ramasamy, Deepa P. Hagemeier, Jesper Genovese, Antonia Valentina Hojnacki, David Weinstock-Guttman, Bianca Dwyer, Michael G. Neuroimage Clin Regular Article BACKGROUND: Greater brain atrophy is associated with disability progression (DP) in patients with multiple sclerosis (PwMS). However, methodological challenges limit its routine clinical use. OBJECTIVE: To determine the feasibility of atrophy measures as markers of DP in PwMS scanned across different MRI field strengths. METHODS: A total of 980 PwMS were scanned on either 1.5 T or 3.0 T MRI scanners. Demographic and clinical data were retrospectively collected, and the presence of DP was determined according to standard clinical trial criteria. Lateral ventricular volume (LVV) change was measured with the NeuroSTREAM technique on clinical routine T2-FLAIR images. Percent brain volume change (PBVC) was measured using SIENA and ventricular cerebrospinal fluid (vCSF) % change was measured using VIENA and SIENAX algorithms on 3D T1-weighted images (WI). Stable vs. DP PwMS were compared using analysis of covariance (ANCOVA). Mixed modeling determined the effect of MRI scanner change on MRI-derived atrophy measures. RESULTS: Longitudinal LVV analysis was successful in all PwMS. SIENA-based PBVC and VIENA-based changes failed in 37.6% of cases, while SIENAX-based vCSF failed in 12.9% of cases. PwMS with DP (n = 241) had significantly greater absolute (20.9% vs. 8.7%, d = 0.66, p < 0.001) and annualized LVV % change (4.1% vs. 2.3%, d = 0.27, p < 0.001) when compared to stable PwMS (n = 739). In subjects with both analyses available, both 3D-T1 and T2-FLAIR-based analyses differentiated PwMS with DP (n = 149). However, only NeuroSTREAM and VIENA-based LVV/vCSF were able to show greater atrophy in PwMS that were scanned on different scanners. PBVC and SIENAX-based vCSF % changes were significantly affected by scanner change (Beta = −0.16, t-statistics = −2.133, p = 0.033 and Beta = −2.08, t-statistics = −4.084, p < 0.001), whereas no MRI scanner change effects on NeuroSTREAM-based PLVVC and VIENA-based vCSF % change were noted. CONCLUSIONS: LVV-based atrophy on T2-FLAIR is a clinically relevant measure in spite of MRI scanner changes and mild disability levels. Elsevier 2021-01-04 /pmc/articles/PMC7816007/ /pubmed/33472143 http://dx.doi.org/10.1016/j.nicl.2020.102554 Text en © 2021 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Regular Article
Jakimovski, Dejan
Zivadinov, Robert
Bergsland, Niels
Ramasamy, Deepa P.
Hagemeier, Jesper
Genovese, Antonia Valentina
Hojnacki, David
Weinstock-Guttman, Bianca
Dwyer, Michael G.
Clinical feasibility of longitudinal lateral ventricular volume measurements on T2-FLAIR across MRI scanner changes
title Clinical feasibility of longitudinal lateral ventricular volume measurements on T2-FLAIR across MRI scanner changes
title_full Clinical feasibility of longitudinal lateral ventricular volume measurements on T2-FLAIR across MRI scanner changes
title_fullStr Clinical feasibility of longitudinal lateral ventricular volume measurements on T2-FLAIR across MRI scanner changes
title_full_unstemmed Clinical feasibility of longitudinal lateral ventricular volume measurements on T2-FLAIR across MRI scanner changes
title_short Clinical feasibility of longitudinal lateral ventricular volume measurements on T2-FLAIR across MRI scanner changes
title_sort clinical feasibility of longitudinal lateral ventricular volume measurements on t2-flair across mri scanner changes
topic Regular Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7816007/
https://www.ncbi.nlm.nih.gov/pubmed/33472143
http://dx.doi.org/10.1016/j.nicl.2020.102554
work_keys_str_mv AT jakimovskidejan clinicalfeasibilityoflongitudinallateralventricularvolumemeasurementsont2flairacrossmriscannerchanges
AT zivadinovrobert clinicalfeasibilityoflongitudinallateralventricularvolumemeasurementsont2flairacrossmriscannerchanges
AT bergslandniels clinicalfeasibilityoflongitudinallateralventricularvolumemeasurementsont2flairacrossmriscannerchanges
AT ramasamydeepap clinicalfeasibilityoflongitudinallateralventricularvolumemeasurementsont2flairacrossmriscannerchanges
AT hagemeierjesper clinicalfeasibilityoflongitudinallateralventricularvolumemeasurementsont2flairacrossmriscannerchanges
AT genoveseantoniavalentina clinicalfeasibilityoflongitudinallateralventricularvolumemeasurementsont2flairacrossmriscannerchanges
AT hojnackidavid clinicalfeasibilityoflongitudinallateralventricularvolumemeasurementsont2flairacrossmriscannerchanges
AT weinstockguttmanbianca clinicalfeasibilityoflongitudinallateralventricularvolumemeasurementsont2flairacrossmriscannerchanges
AT dwyermichaelg clinicalfeasibilityoflongitudinallateralventricularvolumemeasurementsont2flairacrossmriscannerchanges