Cargando…

Novel Noncrossing Y-Stent Technique Using Tapered Proximal End of a Solitaire AB Stent for Coil Embolization of Wide-Neck Bifurcation Aneurysms

The crossing Y-stent method is one of the indispensable techniques to achieve sufficient neck coverage during coil embolization of bifurcation aneurysms with a wide neck and/or branch incorporation. However, the inevitable hourglass-like expansion of the second stent at the crossing point can result...

Descripción completa

Detalles Bibliográficos
Autores principales: Kwon, Hyon-Jo, Lim, Jeong-Wook, Byoun, Hyoung Soo, Koh, Hyeon-Song
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Neurosurgical Society 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7819798/
https://www.ncbi.nlm.nih.gov/pubmed/32640770
http://dx.doi.org/10.3340/jkns.2019.0253
_version_ 1783639068614066176
author Kwon, Hyon-Jo
Lim, Jeong-Wook
Byoun, Hyoung Soo
Koh, Hyeon-Song
author_facet Kwon, Hyon-Jo
Lim, Jeong-Wook
Byoun, Hyoung Soo
Koh, Hyeon-Song
author_sort Kwon, Hyon-Jo
collection PubMed
description The crossing Y-stent method is one of the indispensable techniques to achieve sufficient neck coverage during coil embolization of bifurcation aneurysms with a wide neck and/or branch incorporation. However, the inevitable hourglass-like expansion of the second stent at the crossing point can result in insufficient vessel wall apposition, reduced aneurysm neck coverage, delayed endothelialization, and subsequent higher risks of acute or delayed thrombosis. It also interferes with engagement of the microcatheter into the aneurysm after stent installation. We expected to be able to reduce these disadvantages by installing a noncrossing type Y-stent using the Solitaire AB stent, which is fully retrievable with a tapered proximal end. Here we report the techniques and two successful cases.
format Online
Article
Text
id pubmed-7819798
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Korean Neurosurgical Society
record_format MEDLINE/PubMed
spelling pubmed-78197982021-01-27 Novel Noncrossing Y-Stent Technique Using Tapered Proximal End of a Solitaire AB Stent for Coil Embolization of Wide-Neck Bifurcation Aneurysms Kwon, Hyon-Jo Lim, Jeong-Wook Byoun, Hyoung Soo Koh, Hyeon-Song J Korean Neurosurg Soc Technical Note The crossing Y-stent method is one of the indispensable techniques to achieve sufficient neck coverage during coil embolization of bifurcation aneurysms with a wide neck and/or branch incorporation. However, the inevitable hourglass-like expansion of the second stent at the crossing point can result in insufficient vessel wall apposition, reduced aneurysm neck coverage, delayed endothelialization, and subsequent higher risks of acute or delayed thrombosis. It also interferes with engagement of the microcatheter into the aneurysm after stent installation. We expected to be able to reduce these disadvantages by installing a noncrossing type Y-stent using the Solitaire AB stent, which is fully retrievable with a tapered proximal end. Here we report the techniques and two successful cases. Korean Neurosurgical Society 2021-01 2020-07-09 /pmc/articles/PMC7819798/ /pubmed/32640770 http://dx.doi.org/10.3340/jkns.2019.0253 Text en Copyright © 2021 The Korean Neurosurgical Society This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Note
Kwon, Hyon-Jo
Lim, Jeong-Wook
Byoun, Hyoung Soo
Koh, Hyeon-Song
Novel Noncrossing Y-Stent Technique Using Tapered Proximal End of a Solitaire AB Stent for Coil Embolization of Wide-Neck Bifurcation Aneurysms
title Novel Noncrossing Y-Stent Technique Using Tapered Proximal End of a Solitaire AB Stent for Coil Embolization of Wide-Neck Bifurcation Aneurysms
title_full Novel Noncrossing Y-Stent Technique Using Tapered Proximal End of a Solitaire AB Stent for Coil Embolization of Wide-Neck Bifurcation Aneurysms
title_fullStr Novel Noncrossing Y-Stent Technique Using Tapered Proximal End of a Solitaire AB Stent for Coil Embolization of Wide-Neck Bifurcation Aneurysms
title_full_unstemmed Novel Noncrossing Y-Stent Technique Using Tapered Proximal End of a Solitaire AB Stent for Coil Embolization of Wide-Neck Bifurcation Aneurysms
title_short Novel Noncrossing Y-Stent Technique Using Tapered Proximal End of a Solitaire AB Stent for Coil Embolization of Wide-Neck Bifurcation Aneurysms
title_sort novel noncrossing y-stent technique using tapered proximal end of a solitaire ab stent for coil embolization of wide-neck bifurcation aneurysms
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7819798/
https://www.ncbi.nlm.nih.gov/pubmed/32640770
http://dx.doi.org/10.3340/jkns.2019.0253
work_keys_str_mv AT kwonhyonjo novelnoncrossingystenttechniqueusingtaperedproximalendofasolitaireabstentforcoilembolizationofwideneckbifurcationaneurysms
AT limjeongwook novelnoncrossingystenttechniqueusingtaperedproximalendofasolitaireabstentforcoilembolizationofwideneckbifurcationaneurysms
AT byounhyoungsoo novelnoncrossingystenttechniqueusingtaperedproximalendofasolitaireabstentforcoilembolizationofwideneckbifurcationaneurysms
AT kohhyeonsong novelnoncrossingystenttechniqueusingtaperedproximalendofasolitaireabstentforcoilembolizationofwideneckbifurcationaneurysms