Validation of Gamma Knife Perfexion Dose Profile Distribution by a Modified Variable Ellipsoid Modeling Technique

OBJECTIVE: High precision and accuracy are expected in gamma knife radiosurgery treatment. Because of the requirement of clinically applying complex radiation and dose gradients together with a rapid radiation decline, a dedicated quality assurance program is required to maintain the radiation dosim...

Descripción completa

Detalles Bibliográficos
Autores principales: Hur, Beong Ik, Jin, Seong Jin, Kim, Gyeong Rip, Kwak, Jong Hyeok, Kim, Young Ha, Lee, Sang Weon, Sung, Soon Ki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Neurosurgical Society 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7819799/
https://www.ncbi.nlm.nih.gov/pubmed/33465847
http://dx.doi.org/10.3340/jkns.2020.0186
_version_ 1783639068843704320
author Hur, Beong Ik
Jin, Seong Jin
Kim, Gyeong Rip
Kwak, Jong Hyeok
Kim, Young Ha
Lee, Sang Weon
Sung, Soon Ki
author_facet Hur, Beong Ik
Jin, Seong Jin
Kim, Gyeong Rip
Kwak, Jong Hyeok
Kim, Young Ha
Lee, Sang Weon
Sung, Soon Ki
author_sort Hur, Beong Ik
collection PubMed
description OBJECTIVE: High precision and accuracy are expected in gamma knife radiosurgery treatment. Because of the requirement of clinically applying complex radiation and dose gradients together with a rapid radiation decline, a dedicated quality assurance program is required to maintain the radiation dosimetry and geometric accuracy and to reduce all associated risk factors. This study investigates the validity of Leksell Gamma plan (LGP)10.1.1 system of 5th generation Gamma Knife Perfexion as modified variable ellipsoid modeling technique (VEMT) method. METHODS: To verify LGP10.1.1 system, we compare the treatment plan program system of the Gamma Knife Perfexion, that is, the LGP, with the calculated value of the proposed modified VEMT program. To verify a modified VEMT method, we compare the distributions of the dose of Gamma Knife Perfexion measured by Gafchromic EBT3 and EBT-XD films. For verification, the center of an 80 mm radius solid water phantom is placed in the center of all sectors positioned at 16 mm, 4 mm and 8 mm; that is, the dose distribution is similar to the method used in the x, y, and z directions by the VEMT. The dose distribution in the axial direction is compared and analyzed based on Full-Width-of-Half-Maximum (FWHM) evaluation. RESULTS: The dose profile distribution was evaluated by FWHM, and it showed an average difference of 0.104 mm for the LGP value and 0.130 mm for the EBT-XD film. CONCLUSION: The modified VEMT yielded consistent results in the two processes. The use of the modified VEMT as a verification tool can enable the system to stably test and operate the Gamma Knife Perfexion treatment planning system.
format Online
Article
Text
id pubmed-7819799
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Korean Neurosurgical Society
record_format MEDLINE/PubMed
spelling pubmed-78197992021-01-27 Validation of Gamma Knife Perfexion Dose Profile Distribution by a Modified Variable Ellipsoid Modeling Technique Hur, Beong Ik Jin, Seong Jin Kim, Gyeong Rip Kwak, Jong Hyeok Kim, Young Ha Lee, Sang Weon Sung, Soon Ki J Korean Neurosurg Soc Laboratory Investigation OBJECTIVE: High precision and accuracy are expected in gamma knife radiosurgery treatment. Because of the requirement of clinically applying complex radiation and dose gradients together with a rapid radiation decline, a dedicated quality assurance program is required to maintain the radiation dosimetry and geometric accuracy and to reduce all associated risk factors. This study investigates the validity of Leksell Gamma plan (LGP)10.1.1 system of 5th generation Gamma Knife Perfexion as modified variable ellipsoid modeling technique (VEMT) method. METHODS: To verify LGP10.1.1 system, we compare the treatment plan program system of the Gamma Knife Perfexion, that is, the LGP, with the calculated value of the proposed modified VEMT program. To verify a modified VEMT method, we compare the distributions of the dose of Gamma Knife Perfexion measured by Gafchromic EBT3 and EBT-XD films. For verification, the center of an 80 mm radius solid water phantom is placed in the center of all sectors positioned at 16 mm, 4 mm and 8 mm; that is, the dose distribution is similar to the method used in the x, y, and z directions by the VEMT. The dose distribution in the axial direction is compared and analyzed based on Full-Width-of-Half-Maximum (FWHM) evaluation. RESULTS: The dose profile distribution was evaluated by FWHM, and it showed an average difference of 0.104 mm for the LGP value and 0.130 mm for the EBT-XD film. CONCLUSION: The modified VEMT yielded consistent results in the two processes. The use of the modified VEMT as a verification tool can enable the system to stably test and operate the Gamma Knife Perfexion treatment planning system. Korean Neurosurgical Society 2021-01 2021-01-01 /pmc/articles/PMC7819799/ /pubmed/33465847 http://dx.doi.org/10.3340/jkns.2020.0186 Text en Copyright © 2021 The Korean Neurosurgical Society This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Laboratory Investigation
Hur, Beong Ik
Jin, Seong Jin
Kim, Gyeong Rip
Kwak, Jong Hyeok
Kim, Young Ha
Lee, Sang Weon
Sung, Soon Ki
Validation of Gamma Knife Perfexion Dose Profile Distribution by a Modified Variable Ellipsoid Modeling Technique
title Validation of Gamma Knife Perfexion Dose Profile Distribution by a Modified Variable Ellipsoid Modeling Technique
title_full Validation of Gamma Knife Perfexion Dose Profile Distribution by a Modified Variable Ellipsoid Modeling Technique
title_fullStr Validation of Gamma Knife Perfexion Dose Profile Distribution by a Modified Variable Ellipsoid Modeling Technique
title_full_unstemmed Validation of Gamma Knife Perfexion Dose Profile Distribution by a Modified Variable Ellipsoid Modeling Technique
title_short Validation of Gamma Knife Perfexion Dose Profile Distribution by a Modified Variable Ellipsoid Modeling Technique
title_sort validation of gamma knife perfexion dose profile distribution by a modified variable ellipsoid modeling technique
topic Laboratory Investigation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7819799/
https://www.ncbi.nlm.nih.gov/pubmed/33465847
http://dx.doi.org/10.3340/jkns.2020.0186
work_keys_str_mv AT hurbeongik validationofgammaknifeperfexiondoseprofiledistributionbyamodifiedvariableellipsoidmodelingtechnique
AT jinseongjin validationofgammaknifeperfexiondoseprofiledistributionbyamodifiedvariableellipsoidmodelingtechnique
AT kimgyeongrip validationofgammaknifeperfexiondoseprofiledistributionbyamodifiedvariableellipsoidmodelingtechnique
AT kwakjonghyeok validationofgammaknifeperfexiondoseprofiledistributionbyamodifiedvariableellipsoidmodelingtechnique
AT kimyoungha validationofgammaknifeperfexiondoseprofiledistributionbyamodifiedvariableellipsoidmodelingtechnique
AT leesangweon validationofgammaknifeperfexiondoseprofiledistributionbyamodifiedvariableellipsoidmodelingtechnique
AT sungsoonki validationofgammaknifeperfexiondoseprofiledistributionbyamodifiedvariableellipsoidmodelingtechnique