Cargando…

Technical Note: 4D cone‐beam CT reconstruction from sparse‐view CBCT data for daily motion assessment in pencil beam scanned proton therapy (PBS‐PT)

PURPOSE: The number of pencil beam scanned proton therapy (PBS‐PT) facilities equipped with cone‐beam computed tomography (CBCT) imaging treating thoracic indications is constantly rising. To enable daily internal motion monitoring during PBS‐PT treatments of thoracic tumors, we assess the performan...

Descripción completa

Detalles Bibliográficos
Autores principales: den Otter, Lydia A., Chen, Kuanling, Janssens, Guillaume, Meijers, Arturs, Both, Stefan, Langendijk, Johannes A., Rosen, Lane R., Wu, Hsinshun T., Knopf, Antje‐Christin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7821169/
https://www.ncbi.nlm.nih.gov/pubmed/33011990
http://dx.doi.org/10.1002/mp.14521
_version_ 1783639361315667968
author den Otter, Lydia A.
Chen, Kuanling
Janssens, Guillaume
Meijers, Arturs
Both, Stefan
Langendijk, Johannes A.
Rosen, Lane R.
Wu, Hsinshun T.
Knopf, Antje‐Christin
author_facet den Otter, Lydia A.
Chen, Kuanling
Janssens, Guillaume
Meijers, Arturs
Both, Stefan
Langendijk, Johannes A.
Rosen, Lane R.
Wu, Hsinshun T.
Knopf, Antje‐Christin
author_sort den Otter, Lydia A.
collection PubMed
description PURPOSE: The number of pencil beam scanned proton therapy (PBS‐PT) facilities equipped with cone‐beam computed tomography (CBCT) imaging treating thoracic indications is constantly rising. To enable daily internal motion monitoring during PBS‐PT treatments of thoracic tumors, we assess the performance of Motion‐Aware RecOnstructiOn method using Spatial and Temporal Regularization (MA‐ROOSTER) four‐dimensional CBCT (4DCBCT) reconstruction for sparse‐view CBCT data and a realistic data set of patients treated with proton therapy. METHODS: Daily CBCT projection data for nine non‐small cell lung cancer (NSCLC) patients and one SCLC patient were acquired at a proton gantry system (IBA Proteus® One). Four‐dimensional CBCT images were reconstructed applying the MA‐ROOSTER and the conventional phase‐correlated Feldkamp‐Davis‐Kress (PC‐FDK) method. Image quality was assessed by visual inspection, contrast‐to‐noise ratio (CNR), signal‐to‐noise ratio (SNR), and the structural similarity index measure (SSIM). Furthermore, gross tumor volume (GTV) centroid motion amplitudes were evaluated. RESULTS: Image quality for the 4DCBCT reconstructions using MA‐ROOSTER was superior to the PC‐FDK reconstructions and close to FDK images (median CNR: 1.23 [PC‐FDK], 1.98 [MA‐ROOSTER], and 1.98 [FDK]; median SNR: 2.56 [PC‐FDK], 4.76 [MA‐ROOSTER], and 5.02 [FDK]; median SSIM: 0.18 [PC‐FDK vs FDK], 0.31 [MA‐ROOSTER vs FDK]). The improved image quality of MA‐ROOSTER facilitated GTV contour warping and realistic motion monitoring for most of the reconstructions. CONCLUSION: MA‐ROOSTER based 4DCBCTs performed well in terms of image quality and appear to be promising for daily internal motion monitoring in PBS‐PT treatments of (N)SCLC patients.
format Online
Article
Text
id pubmed-7821169
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-78211692021-01-26 Technical Note: 4D cone‐beam CT reconstruction from sparse‐view CBCT data for daily motion assessment in pencil beam scanned proton therapy (PBS‐PT) den Otter, Lydia A. Chen, Kuanling Janssens, Guillaume Meijers, Arturs Both, Stefan Langendijk, Johannes A. Rosen, Lane R. Wu, Hsinshun T. Knopf, Antje‐Christin Med Phys QUANTITATIVE IMAGING AND IMAGE PROCESSING PURPOSE: The number of pencil beam scanned proton therapy (PBS‐PT) facilities equipped with cone‐beam computed tomography (CBCT) imaging treating thoracic indications is constantly rising. To enable daily internal motion monitoring during PBS‐PT treatments of thoracic tumors, we assess the performance of Motion‐Aware RecOnstructiOn method using Spatial and Temporal Regularization (MA‐ROOSTER) four‐dimensional CBCT (4DCBCT) reconstruction for sparse‐view CBCT data and a realistic data set of patients treated with proton therapy. METHODS: Daily CBCT projection data for nine non‐small cell lung cancer (NSCLC) patients and one SCLC patient were acquired at a proton gantry system (IBA Proteus® One). Four‐dimensional CBCT images were reconstructed applying the MA‐ROOSTER and the conventional phase‐correlated Feldkamp‐Davis‐Kress (PC‐FDK) method. Image quality was assessed by visual inspection, contrast‐to‐noise ratio (CNR), signal‐to‐noise ratio (SNR), and the structural similarity index measure (SSIM). Furthermore, gross tumor volume (GTV) centroid motion amplitudes were evaluated. RESULTS: Image quality for the 4DCBCT reconstructions using MA‐ROOSTER was superior to the PC‐FDK reconstructions and close to FDK images (median CNR: 1.23 [PC‐FDK], 1.98 [MA‐ROOSTER], and 1.98 [FDK]; median SNR: 2.56 [PC‐FDK], 4.76 [MA‐ROOSTER], and 5.02 [FDK]; median SSIM: 0.18 [PC‐FDK vs FDK], 0.31 [MA‐ROOSTER vs FDK]). The improved image quality of MA‐ROOSTER facilitated GTV contour warping and realistic motion monitoring for most of the reconstructions. CONCLUSION: MA‐ROOSTER based 4DCBCTs performed well in terms of image quality and appear to be promising for daily internal motion monitoring in PBS‐PT treatments of (N)SCLC patients. John Wiley and Sons Inc. 2020-10-24 2020-12 /pmc/articles/PMC7821169/ /pubmed/33011990 http://dx.doi.org/10.1002/mp.14521 Text en © 2020 The Authors. Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle QUANTITATIVE IMAGING AND IMAGE PROCESSING
den Otter, Lydia A.
Chen, Kuanling
Janssens, Guillaume
Meijers, Arturs
Both, Stefan
Langendijk, Johannes A.
Rosen, Lane R.
Wu, Hsinshun T.
Knopf, Antje‐Christin
Technical Note: 4D cone‐beam CT reconstruction from sparse‐view CBCT data for daily motion assessment in pencil beam scanned proton therapy (PBS‐PT)
title Technical Note: 4D cone‐beam CT reconstruction from sparse‐view CBCT data for daily motion assessment in pencil beam scanned proton therapy (PBS‐PT)
title_full Technical Note: 4D cone‐beam CT reconstruction from sparse‐view CBCT data for daily motion assessment in pencil beam scanned proton therapy (PBS‐PT)
title_fullStr Technical Note: 4D cone‐beam CT reconstruction from sparse‐view CBCT data for daily motion assessment in pencil beam scanned proton therapy (PBS‐PT)
title_full_unstemmed Technical Note: 4D cone‐beam CT reconstruction from sparse‐view CBCT data for daily motion assessment in pencil beam scanned proton therapy (PBS‐PT)
title_short Technical Note: 4D cone‐beam CT reconstruction from sparse‐view CBCT data for daily motion assessment in pencil beam scanned proton therapy (PBS‐PT)
title_sort technical note: 4d cone‐beam ct reconstruction from sparse‐view cbct data for daily motion assessment in pencil beam scanned proton therapy (pbs‐pt)
topic QUANTITATIVE IMAGING AND IMAGE PROCESSING
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7821169/
https://www.ncbi.nlm.nih.gov/pubmed/33011990
http://dx.doi.org/10.1002/mp.14521
work_keys_str_mv AT denotterlydiaa technicalnote4dconebeamctreconstructionfromsparseviewcbctdatafordailymotionassessmentinpencilbeamscannedprotontherapypbspt
AT chenkuanling technicalnote4dconebeamctreconstructionfromsparseviewcbctdatafordailymotionassessmentinpencilbeamscannedprotontherapypbspt
AT janssensguillaume technicalnote4dconebeamctreconstructionfromsparseviewcbctdatafordailymotionassessmentinpencilbeamscannedprotontherapypbspt
AT meijersarturs technicalnote4dconebeamctreconstructionfromsparseviewcbctdatafordailymotionassessmentinpencilbeamscannedprotontherapypbspt
AT bothstefan technicalnote4dconebeamctreconstructionfromsparseviewcbctdatafordailymotionassessmentinpencilbeamscannedprotontherapypbspt
AT langendijkjohannesa technicalnote4dconebeamctreconstructionfromsparseviewcbctdatafordailymotionassessmentinpencilbeamscannedprotontherapypbspt
AT rosenlaner technicalnote4dconebeamctreconstructionfromsparseviewcbctdatafordailymotionassessmentinpencilbeamscannedprotontherapypbspt
AT wuhsinshunt technicalnote4dconebeamctreconstructionfromsparseviewcbctdatafordailymotionassessmentinpencilbeamscannedprotontherapypbspt
AT knopfantjechristin technicalnote4dconebeamctreconstructionfromsparseviewcbctdatafordailymotionassessmentinpencilbeamscannedprotontherapypbspt