Bi‐objective optimization of catheter positions for high‐dose‐rate prostate brachytherapy
PURPOSE: Bi‐objective simultaneous optimization of catheter positions and dwell times for high‐dose‐rate (HDR) prostate brachytherapy, based directly on dose‐volume indices, has shown promising results. However, optimization with the state‐of‐the‐art evolutionary algorithm MO‐RV‐GOMEA so far require...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7821293/ https://www.ncbi.nlm.nih.gov/pubmed/33000874 http://dx.doi.org/10.1002/mp.14505 |
_version_ | 1783639391343738880 |
---|---|
author | van der Meer, Marjolein C. Bosman, Peter A.N. Niatsetski, Yury Alderliesten, Tanja van Wieringen, Niek Pieters, Bradley R. Bel, Arjan |
author_facet | van der Meer, Marjolein C. Bosman, Peter A.N. Niatsetski, Yury Alderliesten, Tanja van Wieringen, Niek Pieters, Bradley R. Bel, Arjan |
author_sort | van der Meer, Marjolein C. |
collection | PubMed |
description | PURPOSE: Bi‐objective simultaneous optimization of catheter positions and dwell times for high‐dose‐rate (HDR) prostate brachytherapy, based directly on dose‐volume indices, has shown promising results. However, optimization with the state‐of‐the‐art evolutionary algorithm MO‐RV‐GOMEA so far required several hours of runtime, and resulting catheter positions were not always clinically feasible. The aim of this study is to extend the optimization model and apply GPU parallelization to achieve clinically acceptable computation times. The resulting optimization procedure is compared with a previously introduced method based solely on geometric criteria, the adapted Centroidal Voronoi Tessellations (CVT) algorithm. METHODS: Bi‐objective simultaneous optimization was performed with a GPU‐parallelized version of MO‐RV‐GOMEA. This optimization of catheter positions and dwell times was retrospectively applied to the data of 26 patients previously treated with HDR prostate brachytherapy for 8–16 catheters (steps of 2). Optimization of catheter positions using CVT was performed in seconds, after which optimization of only the dwell times using MO‐RV‐GOMEA was performed in 1 min. RESULTS: Simultaneous optimization of catheter positions and dwell times using MO‐RV‐GOMEA was performed in 5 min. For 16 down to 8 catheters (steps of 2), MO‐RV‐GOMEA found plans satisfying the planning‐aims for 20, 20, 18, 14, and 11 out of the 26 patients, respectively. CVT achieved this for 19, 17, 13, 9, and 2 patients, respectively. The P‐value for the difference between MO‐RV‐GOMEA and CVT was 0.023 for 16 catheters, 0.005 for 14 catheters, and <0.001 for 12, 10, and 8 catheters. CONCLUSIONS: With bi‐objective simultaneous optimization on a GPU, high‐quality catheter positions can now be obtained within 5 min, which is clinically acceptable, but slower than CVT. For 16 catheters, the difference between MO‐RV‐GOMEA and CVT is clinically irrelevant. For 14 catheters and less, MO‐RV‐GOMEA outperforms CVT in finding plans satisfying all planning‐aims. |
format | Online Article Text |
id | pubmed-7821293 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-78212932021-01-29 Bi‐objective optimization of catheter positions for high‐dose‐rate prostate brachytherapy van der Meer, Marjolein C. Bosman, Peter A.N. Niatsetski, Yury Alderliesten, Tanja van Wieringen, Niek Pieters, Bradley R. Bel, Arjan Med Phys THERAPEUTIC INTERVENTIONS PURPOSE: Bi‐objective simultaneous optimization of catheter positions and dwell times for high‐dose‐rate (HDR) prostate brachytherapy, based directly on dose‐volume indices, has shown promising results. However, optimization with the state‐of‐the‐art evolutionary algorithm MO‐RV‐GOMEA so far required several hours of runtime, and resulting catheter positions were not always clinically feasible. The aim of this study is to extend the optimization model and apply GPU parallelization to achieve clinically acceptable computation times. The resulting optimization procedure is compared with a previously introduced method based solely on geometric criteria, the adapted Centroidal Voronoi Tessellations (CVT) algorithm. METHODS: Bi‐objective simultaneous optimization was performed with a GPU‐parallelized version of MO‐RV‐GOMEA. This optimization of catheter positions and dwell times was retrospectively applied to the data of 26 patients previously treated with HDR prostate brachytherapy for 8–16 catheters (steps of 2). Optimization of catheter positions using CVT was performed in seconds, after which optimization of only the dwell times using MO‐RV‐GOMEA was performed in 1 min. RESULTS: Simultaneous optimization of catheter positions and dwell times using MO‐RV‐GOMEA was performed in 5 min. For 16 down to 8 catheters (steps of 2), MO‐RV‐GOMEA found plans satisfying the planning‐aims for 20, 20, 18, 14, and 11 out of the 26 patients, respectively. CVT achieved this for 19, 17, 13, 9, and 2 patients, respectively. The P‐value for the difference between MO‐RV‐GOMEA and CVT was 0.023 for 16 catheters, 0.005 for 14 catheters, and <0.001 for 12, 10, and 8 catheters. CONCLUSIONS: With bi‐objective simultaneous optimization on a GPU, high‐quality catheter positions can now be obtained within 5 min, which is clinically acceptable, but slower than CVT. For 16 catheters, the difference between MO‐RV‐GOMEA and CVT is clinically irrelevant. For 14 catheters and less, MO‐RV‐GOMEA outperforms CVT in finding plans satisfying all planning‐aims. John Wiley and Sons Inc. 2020-10-21 2020-12 /pmc/articles/PMC7821293/ /pubmed/33000874 http://dx.doi.org/10.1002/mp.14505 Text en © 2020 The Authors. Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | THERAPEUTIC INTERVENTIONS van der Meer, Marjolein C. Bosman, Peter A.N. Niatsetski, Yury Alderliesten, Tanja van Wieringen, Niek Pieters, Bradley R. Bel, Arjan Bi‐objective optimization of catheter positions for high‐dose‐rate prostate brachytherapy |
title | Bi‐objective optimization of catheter positions for high‐dose‐rate prostate brachytherapy |
title_full | Bi‐objective optimization of catheter positions for high‐dose‐rate prostate brachytherapy |
title_fullStr | Bi‐objective optimization of catheter positions for high‐dose‐rate prostate brachytherapy |
title_full_unstemmed | Bi‐objective optimization of catheter positions for high‐dose‐rate prostate brachytherapy |
title_short | Bi‐objective optimization of catheter positions for high‐dose‐rate prostate brachytherapy |
title_sort | bi‐objective optimization of catheter positions for high‐dose‐rate prostate brachytherapy |
topic | THERAPEUTIC INTERVENTIONS |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7821293/ https://www.ncbi.nlm.nih.gov/pubmed/33000874 http://dx.doi.org/10.1002/mp.14505 |
work_keys_str_mv | AT vandermeermarjoleinc biobjectiveoptimizationofcatheterpositionsforhighdoserateprostatebrachytherapy AT bosmanpeteran biobjectiveoptimizationofcatheterpositionsforhighdoserateprostatebrachytherapy AT niatsetskiyury biobjectiveoptimizationofcatheterpositionsforhighdoserateprostatebrachytherapy AT alderliestentanja biobjectiveoptimizationofcatheterpositionsforhighdoserateprostatebrachytherapy AT vanwieringenniek biobjectiveoptimizationofcatheterpositionsforhighdoserateprostatebrachytherapy AT pietersbradleyr biobjectiveoptimizationofcatheterpositionsforhighdoserateprostatebrachytherapy AT belarjan biobjectiveoptimizationofcatheterpositionsforhighdoserateprostatebrachytherapy |