Cargando…

EvaLuation Using Cardiac Insertable Devices And TelephonE in Hypertrophic Cardiomyopathy (ELUCIDATE HCM): A prospective observational study on incidence of arrhythmias

BACKGROUND: Hypertrophic cardiomyopathy (HCM) is a heterogeneous disease associated with arrhythmias. Non‐sustained ventricular tachycardia (NSVT) is a risk factor for sudden cardiac death and part of the current risk stratification. Furthermore, atrial fibrillation (AF), which increases the risk of...

Descripción completa

Detalles Bibliográficos
Autores principales: Magnusson, Peter, Mörner, Stellan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7821320/
https://www.ncbi.nlm.nih.gov/pubmed/33108031
http://dx.doi.org/10.1111/jce.14792
_version_ 1783639398306283520
author Magnusson, Peter
Mörner, Stellan
author_facet Magnusson, Peter
Mörner, Stellan
author_sort Magnusson, Peter
collection PubMed
description BACKGROUND: Hypertrophic cardiomyopathy (HCM) is a heterogeneous disease associated with arrhythmias. Non‐sustained ventricular tachycardia (NSVT) is a risk factor for sudden cardiac death and part of the current risk stratification. Furthermore, atrial fibrillation (AF), which increases the risk of stroke, is believed to be common in HCM patients. Routine ambulatory monitoring captures the rhythm only periodically over 24–48 h; thus, the true burden of arrhythmia is unknown. The insertable cardiac monitor (ICM) should help determine a more realistic arrhythmia assessment in HCM patients. OBJECTIVE: The purpose of this study was to ascertain the incidence of NSVT, AF, and bradycardia in unselected HCM patients by the use of an ICM. METHODS: Thirty adults, mean age 49.9 ± 12.3 years, 25 (83.3%) males were implanted with a Confirm Rx ICM. The monitoring application was installed on the patient's smartphone, which allowed for patient activation in case of symptoms. The ICM was programmed as follows: ventricular tachycardia (VT) ≥ 160 beats per minute (bpm) for ≥8 intervals, AF ≥ 2 min of duration, and bradycardia ≤ 40 bpm or pause ≥ 3.0 s. RESULTS: The mean calculated 5‐year risk was 2.3%, and 29/30 of the patients had a risk <4%. During follow‐up, AF was found in nine patients (30.0%). At least one episode of NSVT was detected in seven patients (23.3%). In 13 patients (43.3%), sinoatrial block/sinus arrest/sinus bradycardia were seen. No arrhythmia was detected in nine patients (30.0%). CONCLUSION: In this first prospective study using an ICM, the arrhythmia burden in HCM patients yielded 30.0% AF and 23.3% NSVT.
format Online
Article
Text
id pubmed-7821320
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-78213202021-01-29 EvaLuation Using Cardiac Insertable Devices And TelephonE in Hypertrophic Cardiomyopathy (ELUCIDATE HCM): A prospective observational study on incidence of arrhythmias Magnusson, Peter Mörner, Stellan J Cardiovasc Electrophysiol Original ‐ Devices BACKGROUND: Hypertrophic cardiomyopathy (HCM) is a heterogeneous disease associated with arrhythmias. Non‐sustained ventricular tachycardia (NSVT) is a risk factor for sudden cardiac death and part of the current risk stratification. Furthermore, atrial fibrillation (AF), which increases the risk of stroke, is believed to be common in HCM patients. Routine ambulatory monitoring captures the rhythm only periodically over 24–48 h; thus, the true burden of arrhythmia is unknown. The insertable cardiac monitor (ICM) should help determine a more realistic arrhythmia assessment in HCM patients. OBJECTIVE: The purpose of this study was to ascertain the incidence of NSVT, AF, and bradycardia in unselected HCM patients by the use of an ICM. METHODS: Thirty adults, mean age 49.9 ± 12.3 years, 25 (83.3%) males were implanted with a Confirm Rx ICM. The monitoring application was installed on the patient's smartphone, which allowed for patient activation in case of symptoms. The ICM was programmed as follows: ventricular tachycardia (VT) ≥ 160 beats per minute (bpm) for ≥8 intervals, AF ≥ 2 min of duration, and bradycardia ≤ 40 bpm or pause ≥ 3.0 s. RESULTS: The mean calculated 5‐year risk was 2.3%, and 29/30 of the patients had a risk <4%. During follow‐up, AF was found in nine patients (30.0%). At least one episode of NSVT was detected in seven patients (23.3%). In 13 patients (43.3%), sinoatrial block/sinus arrest/sinus bradycardia were seen. No arrhythmia was detected in nine patients (30.0%). CONCLUSION: In this first prospective study using an ICM, the arrhythmia burden in HCM patients yielded 30.0% AF and 23.3% NSVT. John Wiley and Sons Inc. 2020-11-04 2021-01 /pmc/articles/PMC7821320/ /pubmed/33108031 http://dx.doi.org/10.1111/jce.14792 Text en © 2020 The Authors. Journal of Cardiovascular Electrophysiology published by Wiley Periodicals LLC This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original ‐ Devices
Magnusson, Peter
Mörner, Stellan
EvaLuation Using Cardiac Insertable Devices And TelephonE in Hypertrophic Cardiomyopathy (ELUCIDATE HCM): A prospective observational study on incidence of arrhythmias
title EvaLuation Using Cardiac Insertable Devices And TelephonE in Hypertrophic Cardiomyopathy (ELUCIDATE HCM): A prospective observational study on incidence of arrhythmias
title_full EvaLuation Using Cardiac Insertable Devices And TelephonE in Hypertrophic Cardiomyopathy (ELUCIDATE HCM): A prospective observational study on incidence of arrhythmias
title_fullStr EvaLuation Using Cardiac Insertable Devices And TelephonE in Hypertrophic Cardiomyopathy (ELUCIDATE HCM): A prospective observational study on incidence of arrhythmias
title_full_unstemmed EvaLuation Using Cardiac Insertable Devices And TelephonE in Hypertrophic Cardiomyopathy (ELUCIDATE HCM): A prospective observational study on incidence of arrhythmias
title_short EvaLuation Using Cardiac Insertable Devices And TelephonE in Hypertrophic Cardiomyopathy (ELUCIDATE HCM): A prospective observational study on incidence of arrhythmias
title_sort evaluation using cardiac insertable devices and telephone in hypertrophic cardiomyopathy (elucidate hcm): a prospective observational study on incidence of arrhythmias
topic Original ‐ Devices
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7821320/
https://www.ncbi.nlm.nih.gov/pubmed/33108031
http://dx.doi.org/10.1111/jce.14792
work_keys_str_mv AT magnussonpeter evaluationusingcardiacinsertabledevicesandtelephoneinhypertrophiccardiomyopathyelucidatehcmaprospectiveobservationalstudyonincidenceofarrhythmias
AT mornerstellan evaluationusingcardiacinsertabledevicesandtelephoneinhypertrophiccardiomyopathyelucidatehcmaprospectiveobservationalstudyonincidenceofarrhythmias