Cargando…
Smartphone App (2kmFIT-App) for Measuring Cardiorespiratory Fitness: Validity and Reliability Study
BACKGROUND: There is strong evidence suggesting that higher levels of cardiorespiratory fitness (CRF) are associated with a healthier metabolic profile, and that CRF can serve as a powerful predictor of morbidity and mortality. In this context, a smartphone app based on the 2-km walk test (UKK test)...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
JMIR Publications
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7822719/ https://www.ncbi.nlm.nih.gov/pubmed/33416503 http://dx.doi.org/10.2196/14864 |
_version_ | 1783639691575164928 |
---|---|
author | Muntaner-Mas, Adria Martinez-Nicolas, Antonio Quesada, Alberto Cadenas-Sanchez, Cristina Ortega, Francisco B |
author_facet | Muntaner-Mas, Adria Martinez-Nicolas, Antonio Quesada, Alberto Cadenas-Sanchez, Cristina Ortega, Francisco B |
author_sort | Muntaner-Mas, Adria |
collection | PubMed |
description | BACKGROUND: There is strong evidence suggesting that higher levels of cardiorespiratory fitness (CRF) are associated with a healthier metabolic profile, and that CRF can serve as a powerful predictor of morbidity and mortality. In this context, a smartphone app based on the 2-km walk test (UKK test) would provide the possibility to assess CRF remotely in individuals geographically distributed around a country or continent, and even between continents, with minimal equipment and low costs. OBJECTIVE: The overall aim of this study was to evaluate the validity and reliability of 2kmFIT-App developed for Android and iOS mobile operating systems to estimate maximum oxygen consumption (VO2max) as an indicator of CRF. The specific aims of the study were to determine the validity of 2kmFIT-App to track distance and calculate heart rate (HR). METHODS: Twenty participants were included for field-testing validation and reliability analysis. The participants completed the UKK test twice using 2kmFIT-App. Distance and HR were measured with the app as well as with accurate methods, and VO2max was estimated using the UKK test equation. RESULTS: The validity results showed the following mean differences (app minus criterion): distance (–70.40, SD 51.47 meters), time (–0.59, SD 0.45 minutes), HR (–16.75, SD 9.96 beats/minute), and VO2max (3.59, SD 2.01 ml/kg/min). There was moderate validity found for HR (intraclass correlation coefficient [ICC] 0.731, 95% CI –0.211 to 0.942) and good validity found for VO2max (ICC 0.878, 95% CI –0.125 to 0.972). The reliability results showed the following mean differences (retest minus test): app distance (25.99, SD 43.21 meters), app time (–0.15, SD 0.94 seconds), pace (–0.18, SD 0.33 min/km), app HR (–4.5, 13.44 beats/minute), and app VO2max (0.92, SD 3.04 ml/kg/min). There was good reliability for app HR (ICC 0.897, 95% CI 0.742-0.959) and excellent validity for app VO2max (ICC 0.932, 95% CI 0.830-0.973). All of these findings were observed when using the app with an Android operating system, whereas validity was poor when the app was used with iOS. CONCLUSIONS: This study shows that 2kmFIT-App is a new, scientifically valid and reliable tool able to objectively and remotely estimate CRF, HR, and distance with an Android but not iOS mobile operating system. However, certain limitations such as the time required by 2kmFIT-App to calculate HR or the temperature environment should be considered when using the app. |
format | Online Article Text |
id | pubmed-7822719 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | JMIR Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-78227192021-01-26 Smartphone App (2kmFIT-App) for Measuring Cardiorespiratory Fitness: Validity and Reliability Study Muntaner-Mas, Adria Martinez-Nicolas, Antonio Quesada, Alberto Cadenas-Sanchez, Cristina Ortega, Francisco B JMIR Mhealth Uhealth Original Paper BACKGROUND: There is strong evidence suggesting that higher levels of cardiorespiratory fitness (CRF) are associated with a healthier metabolic profile, and that CRF can serve as a powerful predictor of morbidity and mortality. In this context, a smartphone app based on the 2-km walk test (UKK test) would provide the possibility to assess CRF remotely in individuals geographically distributed around a country or continent, and even between continents, with minimal equipment and low costs. OBJECTIVE: The overall aim of this study was to evaluate the validity and reliability of 2kmFIT-App developed for Android and iOS mobile operating systems to estimate maximum oxygen consumption (VO2max) as an indicator of CRF. The specific aims of the study were to determine the validity of 2kmFIT-App to track distance and calculate heart rate (HR). METHODS: Twenty participants were included for field-testing validation and reliability analysis. The participants completed the UKK test twice using 2kmFIT-App. Distance and HR were measured with the app as well as with accurate methods, and VO2max was estimated using the UKK test equation. RESULTS: The validity results showed the following mean differences (app minus criterion): distance (–70.40, SD 51.47 meters), time (–0.59, SD 0.45 minutes), HR (–16.75, SD 9.96 beats/minute), and VO2max (3.59, SD 2.01 ml/kg/min). There was moderate validity found for HR (intraclass correlation coefficient [ICC] 0.731, 95% CI –0.211 to 0.942) and good validity found for VO2max (ICC 0.878, 95% CI –0.125 to 0.972). The reliability results showed the following mean differences (retest minus test): app distance (25.99, SD 43.21 meters), app time (–0.15, SD 0.94 seconds), pace (–0.18, SD 0.33 min/km), app HR (–4.5, 13.44 beats/minute), and app VO2max (0.92, SD 3.04 ml/kg/min). There was good reliability for app HR (ICC 0.897, 95% CI 0.742-0.959) and excellent validity for app VO2max (ICC 0.932, 95% CI 0.830-0.973). All of these findings were observed when using the app with an Android operating system, whereas validity was poor when the app was used with iOS. CONCLUSIONS: This study shows that 2kmFIT-App is a new, scientifically valid and reliable tool able to objectively and remotely estimate CRF, HR, and distance with an Android but not iOS mobile operating system. However, certain limitations such as the time required by 2kmFIT-App to calculate HR or the temperature environment should be considered when using the app. JMIR Publications 2021-01-08 /pmc/articles/PMC7822719/ /pubmed/33416503 http://dx.doi.org/10.2196/14864 Text en ©Adria Muntaner-Mas, Antonio Martinez-Nicolas, Alberto Quesada, Cristina Cadenas-Sanchez, Francisco B Ortega. Originally published in JMIR mHealth and uHealth (http://mhealth.jmir.org), 08.01.2021. https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR mHealth and uHealth, is properly cited. The complete bibliographic information, a link to the original publication on http://mhealth.jmir.org/, as well as this copyright and license information must be included. |
spellingShingle | Original Paper Muntaner-Mas, Adria Martinez-Nicolas, Antonio Quesada, Alberto Cadenas-Sanchez, Cristina Ortega, Francisco B Smartphone App (2kmFIT-App) for Measuring Cardiorespiratory Fitness: Validity and Reliability Study |
title | Smartphone App (2kmFIT-App) for Measuring Cardiorespiratory Fitness: Validity and Reliability Study |
title_full | Smartphone App (2kmFIT-App) for Measuring Cardiorespiratory Fitness: Validity and Reliability Study |
title_fullStr | Smartphone App (2kmFIT-App) for Measuring Cardiorespiratory Fitness: Validity and Reliability Study |
title_full_unstemmed | Smartphone App (2kmFIT-App) for Measuring Cardiorespiratory Fitness: Validity and Reliability Study |
title_short | Smartphone App (2kmFIT-App) for Measuring Cardiorespiratory Fitness: Validity and Reliability Study |
title_sort | smartphone app (2kmfit-app) for measuring cardiorespiratory fitness: validity and reliability study |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7822719/ https://www.ncbi.nlm.nih.gov/pubmed/33416503 http://dx.doi.org/10.2196/14864 |
work_keys_str_mv | AT muntanermasadria smartphoneapp2kmfitappformeasuringcardiorespiratoryfitnessvalidityandreliabilitystudy AT martineznicolasantonio smartphoneapp2kmfitappformeasuringcardiorespiratoryfitnessvalidityandreliabilitystudy AT quesadaalberto smartphoneapp2kmfitappformeasuringcardiorespiratoryfitnessvalidityandreliabilitystudy AT cadenassanchezcristina smartphoneapp2kmfitappformeasuringcardiorespiratoryfitnessvalidityandreliabilitystudy AT ortegafranciscob smartphoneapp2kmfitappformeasuringcardiorespiratoryfitnessvalidityandreliabilitystudy |