“Mind the Gap”: An 85-Year-Old Man with Severe Tricuspid Valve Regurgitation Who Underwent Percutaneous Edge-to-Edge Valve Leaflet Plication Using the New and Advanced MitraClip XTR System
Patient: Male, 85-year-old Final Diagnosis: Severe tricuspid regurgitation Symptoms: Cardiac decompenstion • dyspnea Medication: — Clinical Procedure: Edge-to-edge valve repair using MitraCLip System XTR Specialty: Cardiology OBJECTIVE: Unusual clinical course BACKGROUND: Severe tricuspid valve regu...
Autores principales: | Mueller, Karin Anne Lydia, Jorbenadze, Rezo, Gawaz, Meinrad, Schreieck, Juergen, Seizer, Peter |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Scientific Literature, Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7823151/ https://www.ncbi.nlm.nih.gov/pubmed/33456048 http://dx.doi.org/10.12659/AJCR.928089 |
Ejemplares similares
-
Utility of MitraClip XTR System in Percutaneous Edge-To-Edge Mitral Valve Repair for Severe Flail Leaflet
por: Al-Hijji, Mohammed, et al.
Publicado: (2020) -
Sequential Venous Percutaneous Transluminal Angioplasty and Balloon Dilatation of the Interatrial Septum during Percutaneous Edge-to-Edge Mitral Valve Repair
por: Jorbenadze, Rezo, et al.
Publicado: (2017) -
PASCAL versus MitraClip-XTR edge-to-edge device for the treatment of tricuspid regurgitation: a propensity-matched analysis
por: Sugiura, Atsushi, et al.
Publicado: (2020) -
Percutaneous edge‐to‐edge repair of severe mitral regurgitation using the MitraClip XTR versus NTR system
por: Doldi, Philipp M., et al.
Publicado: (2021) -
Percutaneous Mitral Valve Edge-to-Edge Repair Using Volume Intracardiac Echocardiography—First in Human Experience
por: Patzelt, Johannes, et al.
Publicado: (2017)