Cargando…
Development and Evaluation of an Electrochemical Biosensor for Detection of Dengue-Specific IgM Antibody in Serum Samples
Dengue is an arbovirus disease transmitted mainly by Aedes mosquitoes. As dengue shares similar clinical symptoms with other infectious diseases, prompt and accurate diagnosis is pivotal to clinicians’ decisions on appropriate management. Conventional diagnostic tests to detect the dengue-specific I...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7824051/ https://www.ncbi.nlm.nih.gov/pubmed/33375384 http://dx.doi.org/10.3390/diagnostics11010033 |
_version_ | 1783639982482653184 |
---|---|
author | Parkash, Om Abdullah, Muhammad Amiruddin Yean, Chan Yean Sekaran, Shamala Devi Shueb, Rafidah Hanim |
author_facet | Parkash, Om Abdullah, Muhammad Amiruddin Yean, Chan Yean Sekaran, Shamala Devi Shueb, Rafidah Hanim |
author_sort | Parkash, Om |
collection | PubMed |
description | Dengue is an arbovirus disease transmitted mainly by Aedes mosquitoes. As dengue shares similar clinical symptoms with other infectious diseases, prompt and accurate diagnosis is pivotal to clinicians’ decisions on appropriate management. Conventional diagnostic tests to detect the dengue-specific IgM antibody are limited in their performance and ease of use. To address these issues, we developed and evaluated a biosensor based on screen-printed carbon electrodes (SPCEs) for the detection of dengue-specific immunoglobulin M (IgM) antibodies. Various optimisations were performed in order to increase the sensitivity and specificity of the biosensor. For optimal and proper orientation of the paratope sites of goat anti-human IgM capture antibodies (GAHICA), various antibody techniques, including passive, covalent, protein A, protein G and streptavidin/biotin systems, were tested on the SPCEs. The assay reagents for the biosensor were also optimised prior to its evaluation. Analytical sensitivity evaluation was carried out using pooled sera, while analytical specificity evaluation was conducted on a panel of six non-dengue serum samples. Subsequently, diagnostic sensitivity and specificity evaluation were performed using 144 reference samples. Electrochemical current signals generated from H(2)O(2) catalysed by HRP-labelled anti-dengue detection antibodies were measured using the chronoamperometric technique. With a limit of detection (LOD) of 10(6) serum dilution, the analytical sensitivity of the developed biosensor was 10 times higher than commercial ELISA. The analytical specificity of this dengue IgM biosensor was 100%. Similarly, the biosensor’s diagnostic performance was 100% for sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). These findings suggest that the developed biosensor has a great potential to be used to diagnose dengue after seroconversion. |
format | Online Article Text |
id | pubmed-7824051 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-78240512021-01-24 Development and Evaluation of an Electrochemical Biosensor for Detection of Dengue-Specific IgM Antibody in Serum Samples Parkash, Om Abdullah, Muhammad Amiruddin Yean, Chan Yean Sekaran, Shamala Devi Shueb, Rafidah Hanim Diagnostics (Basel) Article Dengue is an arbovirus disease transmitted mainly by Aedes mosquitoes. As dengue shares similar clinical symptoms with other infectious diseases, prompt and accurate diagnosis is pivotal to clinicians’ decisions on appropriate management. Conventional diagnostic tests to detect the dengue-specific IgM antibody are limited in their performance and ease of use. To address these issues, we developed and evaluated a biosensor based on screen-printed carbon electrodes (SPCEs) for the detection of dengue-specific immunoglobulin M (IgM) antibodies. Various optimisations were performed in order to increase the sensitivity and specificity of the biosensor. For optimal and proper orientation of the paratope sites of goat anti-human IgM capture antibodies (GAHICA), various antibody techniques, including passive, covalent, protein A, protein G and streptavidin/biotin systems, were tested on the SPCEs. The assay reagents for the biosensor were also optimised prior to its evaluation. Analytical sensitivity evaluation was carried out using pooled sera, while analytical specificity evaluation was conducted on a panel of six non-dengue serum samples. Subsequently, diagnostic sensitivity and specificity evaluation were performed using 144 reference samples. Electrochemical current signals generated from H(2)O(2) catalysed by HRP-labelled anti-dengue detection antibodies were measured using the chronoamperometric technique. With a limit of detection (LOD) of 10(6) serum dilution, the analytical sensitivity of the developed biosensor was 10 times higher than commercial ELISA. The analytical specificity of this dengue IgM biosensor was 100%. Similarly, the biosensor’s diagnostic performance was 100% for sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). These findings suggest that the developed biosensor has a great potential to be used to diagnose dengue after seroconversion. MDPI 2020-12-26 /pmc/articles/PMC7824051/ /pubmed/33375384 http://dx.doi.org/10.3390/diagnostics11010033 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Parkash, Om Abdullah, Muhammad Amiruddin Yean, Chan Yean Sekaran, Shamala Devi Shueb, Rafidah Hanim Development and Evaluation of an Electrochemical Biosensor for Detection of Dengue-Specific IgM Antibody in Serum Samples |
title | Development and Evaluation of an Electrochemical Biosensor for Detection of Dengue-Specific IgM Antibody in Serum Samples |
title_full | Development and Evaluation of an Electrochemical Biosensor for Detection of Dengue-Specific IgM Antibody in Serum Samples |
title_fullStr | Development and Evaluation of an Electrochemical Biosensor for Detection of Dengue-Specific IgM Antibody in Serum Samples |
title_full_unstemmed | Development and Evaluation of an Electrochemical Biosensor for Detection of Dengue-Specific IgM Antibody in Serum Samples |
title_short | Development and Evaluation of an Electrochemical Biosensor for Detection of Dengue-Specific IgM Antibody in Serum Samples |
title_sort | development and evaluation of an electrochemical biosensor for detection of dengue-specific igm antibody in serum samples |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7824051/ https://www.ncbi.nlm.nih.gov/pubmed/33375384 http://dx.doi.org/10.3390/diagnostics11010033 |
work_keys_str_mv | AT parkashom developmentandevaluationofanelectrochemicalbiosensorfordetectionofdenguespecificigmantibodyinserumsamples AT abdullahmuhammadamiruddin developmentandevaluationofanelectrochemicalbiosensorfordetectionofdenguespecificigmantibodyinserumsamples AT yeanchanyean developmentandevaluationofanelectrochemicalbiosensorfordetectionofdenguespecificigmantibodyinserumsamples AT sekaranshamaladevi developmentandevaluationofanelectrochemicalbiosensorfordetectionofdenguespecificigmantibodyinserumsamples AT shuebrafidahhanim developmentandevaluationofanelectrochemicalbiosensorfordetectionofdenguespecificigmantibodyinserumsamples |