Cargando…

Detection of Active BoNT/C and D by EndoPep-MS Using MALDI Biotyper Instrument and Comparison with the Mouse Test Bioassay

Botulinum neurotoxins (BoNTs) are among the most poisonous known biological substances, and therefore the availability of reliable, easy-to use tools for BoNT detection are important goals for food safety and human and animal health. The reference method for toxin detection and identification is the...

Descripción completa

Detalles Bibliográficos
Autores principales: Drigo, Ilenia, Tonon, Elena, Pascoletti, Simone, Anniballi, Fabrizio, Kalb, Suzanne R., Bano, Luca
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7824663/
https://www.ncbi.nlm.nih.gov/pubmed/33374240
http://dx.doi.org/10.3390/toxins13010010
_version_ 1783640132753031168
author Drigo, Ilenia
Tonon, Elena
Pascoletti, Simone
Anniballi, Fabrizio
Kalb, Suzanne R.
Bano, Luca
author_facet Drigo, Ilenia
Tonon, Elena
Pascoletti, Simone
Anniballi, Fabrizio
Kalb, Suzanne R.
Bano, Luca
author_sort Drigo, Ilenia
collection PubMed
description Botulinum neurotoxins (BoNTs) are among the most poisonous known biological substances, and therefore the availability of reliable, easy-to use tools for BoNT detection are important goals for food safety and human and animal health. The reference method for toxin detection and identification is the mouse bioassay (MBA). An EndoPep-MS method for BoNT differentiation has been developed based on mass spectrometry. We have validated and implemented the EndoPep-MS method on a Bruker MALDI Biotyper for the detection of BoNT/C and D serotypes. The method was extensively validated using experimentally and naturally contaminated samples comparing the results with those obtained with the MBA. Overall, the limit of detection (LoD) for both C and D toxins were less than or equal to two mouse lethal dose 50 (mLD(50)) per 500 µL for all tested matrices with the exception of feces spiked with BoNT/C which showed signals not-related to specific peptide fragments. Diagnostic sensitivity, specificity and positive predictive value were 100% (95% CI: 87.66–100%), 96.08% (95% CI: 86.54–99.52%), and 93.33% (95% CI: 78.25–98.20%), respectively, and accuracy was 97.47% (95% CI: 91.15–99.69%). In conclusion, the tests carried out showed that the EndoPep-MS method, initially developed using more powerful mass spectrometers, can be applied to the Bruker MALDI Biotyper instrument with excellent results including for detection of the proteolytic activity of BoNT/C, BoNT/D, BoNT/CD, and BoNT/DC toxins.
format Online
Article
Text
id pubmed-7824663
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-78246632021-01-24 Detection of Active BoNT/C and D by EndoPep-MS Using MALDI Biotyper Instrument and Comparison with the Mouse Test Bioassay Drigo, Ilenia Tonon, Elena Pascoletti, Simone Anniballi, Fabrizio Kalb, Suzanne R. Bano, Luca Toxins (Basel) Article Botulinum neurotoxins (BoNTs) are among the most poisonous known biological substances, and therefore the availability of reliable, easy-to use tools for BoNT detection are important goals for food safety and human and animal health. The reference method for toxin detection and identification is the mouse bioassay (MBA). An EndoPep-MS method for BoNT differentiation has been developed based on mass spectrometry. We have validated and implemented the EndoPep-MS method on a Bruker MALDI Biotyper for the detection of BoNT/C and D serotypes. The method was extensively validated using experimentally and naturally contaminated samples comparing the results with those obtained with the MBA. Overall, the limit of detection (LoD) for both C and D toxins were less than or equal to two mouse lethal dose 50 (mLD(50)) per 500 µL for all tested matrices with the exception of feces spiked with BoNT/C which showed signals not-related to specific peptide fragments. Diagnostic sensitivity, specificity and positive predictive value were 100% (95% CI: 87.66–100%), 96.08% (95% CI: 86.54–99.52%), and 93.33% (95% CI: 78.25–98.20%), respectively, and accuracy was 97.47% (95% CI: 91.15–99.69%). In conclusion, the tests carried out showed that the EndoPep-MS method, initially developed using more powerful mass spectrometers, can be applied to the Bruker MALDI Biotyper instrument with excellent results including for detection of the proteolytic activity of BoNT/C, BoNT/D, BoNT/CD, and BoNT/DC toxins. MDPI 2020-12-24 /pmc/articles/PMC7824663/ /pubmed/33374240 http://dx.doi.org/10.3390/toxins13010010 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Drigo, Ilenia
Tonon, Elena
Pascoletti, Simone
Anniballi, Fabrizio
Kalb, Suzanne R.
Bano, Luca
Detection of Active BoNT/C and D by EndoPep-MS Using MALDI Biotyper Instrument and Comparison with the Mouse Test Bioassay
title Detection of Active BoNT/C and D by EndoPep-MS Using MALDI Biotyper Instrument and Comparison with the Mouse Test Bioassay
title_full Detection of Active BoNT/C and D by EndoPep-MS Using MALDI Biotyper Instrument and Comparison with the Mouse Test Bioassay
title_fullStr Detection of Active BoNT/C and D by EndoPep-MS Using MALDI Biotyper Instrument and Comparison with the Mouse Test Bioassay
title_full_unstemmed Detection of Active BoNT/C and D by EndoPep-MS Using MALDI Biotyper Instrument and Comparison with the Mouse Test Bioassay
title_short Detection of Active BoNT/C and D by EndoPep-MS Using MALDI Biotyper Instrument and Comparison with the Mouse Test Bioassay
title_sort detection of active bont/c and d by endopep-ms using maldi biotyper instrument and comparison with the mouse test bioassay
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7824663/
https://www.ncbi.nlm.nih.gov/pubmed/33374240
http://dx.doi.org/10.3390/toxins13010010
work_keys_str_mv AT drigoilenia detectionofactivebontcanddbyendopepmsusingmaldibiotyperinstrumentandcomparisonwiththemousetestbioassay
AT tononelena detectionofactivebontcanddbyendopepmsusingmaldibiotyperinstrumentandcomparisonwiththemousetestbioassay
AT pascolettisimone detectionofactivebontcanddbyendopepmsusingmaldibiotyperinstrumentandcomparisonwiththemousetestbioassay
AT anniballifabrizio detectionofactivebontcanddbyendopepmsusingmaldibiotyperinstrumentandcomparisonwiththemousetestbioassay
AT kalbsuzanner detectionofactivebontcanddbyendopepmsusingmaldibiotyperinstrumentandcomparisonwiththemousetestbioassay
AT banoluca detectionofactivebontcanddbyendopepmsusingmaldibiotyperinstrumentandcomparisonwiththemousetestbioassay