Cargando…
The use of an O-arm in endonasal endoscopic operations of the skull base
BACKGROUND: Endoscopic endonasal transsphenoidal approaches are broadly used nowadays for a vast spectrum of pathologies sited in the anterior and middle cranial fossa. The usage of neuronavigation systems (neuronavigation) in these surgeries is crucial for improving orientations deeply inside the s...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7825238/ https://www.ncbi.nlm.nih.gov/pubmed/33485359 http://dx.doi.org/10.1186/s12893-021-01066-w |
_version_ | 1783640261455249408 |
---|---|
author | Novák, Vlastimil Hrabálek, Lumír Valošek, Jan Jablonský, Jakub Hoza, Jiří Korčáková, Ivona Hampl, Martin Stejskal, Přemysl Hučko, Csaba |
author_facet | Novák, Vlastimil Hrabálek, Lumír Valošek, Jan Jablonský, Jakub Hoza, Jiří Korčáková, Ivona Hampl, Martin Stejskal, Přemysl Hučko, Csaba |
author_sort | Novák, Vlastimil |
collection | PubMed |
description | BACKGROUND: Endoscopic endonasal transsphenoidal approaches are broadly used nowadays for a vast spectrum of pathologies sited in the anterior and middle cranial fossa. The usage of neuronavigation systems (neuronavigation) in these surgeries is crucial for improving orientations deeply inside the skull and increasing patient safety. METHODS: The aim of this study was to assess the use of optical neuronavigation, together with an intraoperative O-arm O2 imaging system, in a group of patients with hypophyseal adenoma that underwent a transnasal transsphenoidal surgery, and correlate the accuracy and its deviation during the navigational process against the use of conventional neuronavigation that uses preoperative MRI and CT scans. The overall group consisted of six patients, between 39 and 78 years old, with a diagnosis of hypophyseal adenoma. Patients were treated with an endoscopic transsphenoidal technique and all of them underwent preoperative MRI and CT scans of the brain. These images were used in the neuronavigation system StealthStation S7(®) during the surgery, where we defined two bony anatomical landmarks, such as a vomer or the origin of an intrasphenoidal septum, in each operated patient. The tip of the navigational instrument, under endoscopic control, pointed to these landmarks and the distance between the tip and the bony structure was measured on the neuronavigation system. Afterwards, intraoperative 3D x-ray imaging was performed via the mobile system O-arm O2(®) system with automatic transfer into the navigational system. Under endoscopic guidance, we localized the identical bony anatomical landmarks used in the previous measurement and re-measured the distance between the tip and bony landmark in images acquired by the O-arm. The results of both measurements were statistically compared. RESULTS: The mean error of accuracy during conventional neuronavigation with usage of preoperative CT and MRI scans was 2.65 mm. During the neuronavigation, with utilization of intraoperative 3D O-arm images, the mean error of accuracy 0 mm. These mean errors of accuracy (both measurement methods were compared by nonparametric Wilcoxon test) had a statistically significant difference (p = 0.043). CONCLUSIONS: Based on this preliminary clinical study, we conclude that the O-arm is capable of providing intraoperative x-ray 3D images in sufficient spatial resolution in a clinically feasible acquisition. The mean error of accuracy during intraoperative navigation, based on 3D O-arm scans at the skull base, is significantly lower compared to the usage of navigation using conventional presurgical CT and MRI images. This suggests the suitability of this method for utilization during endoscopic endonasal skull base approaches. |
format | Online Article Text |
id | pubmed-7825238 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-78252382021-01-25 The use of an O-arm in endonasal endoscopic operations of the skull base Novák, Vlastimil Hrabálek, Lumír Valošek, Jan Jablonský, Jakub Hoza, Jiří Korčáková, Ivona Hampl, Martin Stejskal, Přemysl Hučko, Csaba BMC Surg Research Article BACKGROUND: Endoscopic endonasal transsphenoidal approaches are broadly used nowadays for a vast spectrum of pathologies sited in the anterior and middle cranial fossa. The usage of neuronavigation systems (neuronavigation) in these surgeries is crucial for improving orientations deeply inside the skull and increasing patient safety. METHODS: The aim of this study was to assess the use of optical neuronavigation, together with an intraoperative O-arm O2 imaging system, in a group of patients with hypophyseal adenoma that underwent a transnasal transsphenoidal surgery, and correlate the accuracy and its deviation during the navigational process against the use of conventional neuronavigation that uses preoperative MRI and CT scans. The overall group consisted of six patients, between 39 and 78 years old, with a diagnosis of hypophyseal adenoma. Patients were treated with an endoscopic transsphenoidal technique and all of them underwent preoperative MRI and CT scans of the brain. These images were used in the neuronavigation system StealthStation S7(®) during the surgery, where we defined two bony anatomical landmarks, such as a vomer or the origin of an intrasphenoidal septum, in each operated patient. The tip of the navigational instrument, under endoscopic control, pointed to these landmarks and the distance between the tip and the bony structure was measured on the neuronavigation system. Afterwards, intraoperative 3D x-ray imaging was performed via the mobile system O-arm O2(®) system with automatic transfer into the navigational system. Under endoscopic guidance, we localized the identical bony anatomical landmarks used in the previous measurement and re-measured the distance between the tip and bony landmark in images acquired by the O-arm. The results of both measurements were statistically compared. RESULTS: The mean error of accuracy during conventional neuronavigation with usage of preoperative CT and MRI scans was 2.65 mm. During the neuronavigation, with utilization of intraoperative 3D O-arm images, the mean error of accuracy 0 mm. These mean errors of accuracy (both measurement methods were compared by nonparametric Wilcoxon test) had a statistically significant difference (p = 0.043). CONCLUSIONS: Based on this preliminary clinical study, we conclude that the O-arm is capable of providing intraoperative x-ray 3D images in sufficient spatial resolution in a clinically feasible acquisition. The mean error of accuracy during intraoperative navigation, based on 3D O-arm scans at the skull base, is significantly lower compared to the usage of navigation using conventional presurgical CT and MRI images. This suggests the suitability of this method for utilization during endoscopic endonasal skull base approaches. BioMed Central 2021-01-23 /pmc/articles/PMC7825238/ /pubmed/33485359 http://dx.doi.org/10.1186/s12893-021-01066-w Text en © The Author(s) 2021 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Novák, Vlastimil Hrabálek, Lumír Valošek, Jan Jablonský, Jakub Hoza, Jiří Korčáková, Ivona Hampl, Martin Stejskal, Přemysl Hučko, Csaba The use of an O-arm in endonasal endoscopic operations of the skull base |
title | The use of an O-arm in endonasal endoscopic operations of the skull base |
title_full | The use of an O-arm in endonasal endoscopic operations of the skull base |
title_fullStr | The use of an O-arm in endonasal endoscopic operations of the skull base |
title_full_unstemmed | The use of an O-arm in endonasal endoscopic operations of the skull base |
title_short | The use of an O-arm in endonasal endoscopic operations of the skull base |
title_sort | use of an o-arm in endonasal endoscopic operations of the skull base |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7825238/ https://www.ncbi.nlm.nih.gov/pubmed/33485359 http://dx.doi.org/10.1186/s12893-021-01066-w |
work_keys_str_mv | AT novakvlastimil theuseofanoarminendonasalendoscopicoperationsoftheskullbase AT hrabaleklumir theuseofanoarminendonasalendoscopicoperationsoftheskullbase AT valosekjan theuseofanoarminendonasalendoscopicoperationsoftheskullbase AT jablonskyjakub theuseofanoarminendonasalendoscopicoperationsoftheskullbase AT hozajiri theuseofanoarminendonasalendoscopicoperationsoftheskullbase AT korcakovaivona theuseofanoarminendonasalendoscopicoperationsoftheskullbase AT hamplmartin theuseofanoarminendonasalendoscopicoperationsoftheskullbase AT stejskalpremysl theuseofanoarminendonasalendoscopicoperationsoftheskullbase AT huckocsaba theuseofanoarminendonasalendoscopicoperationsoftheskullbase AT novakvlastimil useofanoarminendonasalendoscopicoperationsoftheskullbase AT hrabaleklumir useofanoarminendonasalendoscopicoperationsoftheskullbase AT valosekjan useofanoarminendonasalendoscopicoperationsoftheskullbase AT jablonskyjakub useofanoarminendonasalendoscopicoperationsoftheskullbase AT hozajiri useofanoarminendonasalendoscopicoperationsoftheskullbase AT korcakovaivona useofanoarminendonasalendoscopicoperationsoftheskullbase AT hamplmartin useofanoarminendonasalendoscopicoperationsoftheskullbase AT stejskalpremysl useofanoarminendonasalendoscopicoperationsoftheskullbase AT huckocsaba useofanoarminendonasalendoscopicoperationsoftheskullbase |