Hearing rehabilitation after subtotal cochleoectomy using a new, perimodiolar malleable cochlear implant electrode array: a preliminary report

PURPOSE: We here report about the first surgical experience and audiological outcome using a new, perimodiolar malleable cochlear implant electrode array for hearing rehabilitation after subtotal cochleoectomy for intralabyrinthine schwannoma (ILS). METHOD: Based on a cochlear implant with MRI compa...

Descripción completa

Detalles Bibliográficos
Autores principales: Plontke, Stefan K., Fröhlich, Laura, Cozma, Sebastian, Koitschev, Assen, Reimann, Katrin, Weiß, Rainer, Götze, Gerrit, Seiwerth, Ingmar, Kösling, Sabrina, Rahne, Torsten
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7826316/
https://www.ncbi.nlm.nih.gov/pubmed/32504199
http://dx.doi.org/10.1007/s00405-020-06098-1
_version_ 1783640511520702464
author Plontke, Stefan K.
Fröhlich, Laura
Cozma, Sebastian
Koitschev, Assen
Reimann, Katrin
Weiß, Rainer
Götze, Gerrit
Seiwerth, Ingmar
Kösling, Sabrina
Rahne, Torsten
author_facet Plontke, Stefan K.
Fröhlich, Laura
Cozma, Sebastian
Koitschev, Assen
Reimann, Katrin
Weiß, Rainer
Götze, Gerrit
Seiwerth, Ingmar
Kösling, Sabrina
Rahne, Torsten
author_sort Plontke, Stefan K.
collection PubMed
description PURPOSE: We here report about the first surgical experience and audiological outcome using a new, perimodiolar malleable cochlear implant electrode array for hearing rehabilitation after subtotal cochleoectomy for intralabyrinthine schwannoma (ILS). METHOD: Based on a cochlear implant with MRI compatibility of the magnet in the receiver coil up to 3 T, a cochlear implant electrode array was developed that is malleable and can be placed perimodiolar after tumor removal from the cochlea via subtotal cochleoectomy. Malleability was reached by incorporating a nitinol wire into the silicone of the electrode array lateral to the electrode contacts. The custom-made device was implanted in four patients with intracochlear, intravestibulocochlear or transmodiolar schwannomas. Outcome was assessed by evaluating the feasibility of the surgical procedure and by measuring sound field thresholds and word recognition scores. RESULTS: After complete or partial tumor removal via subtotal cochleoectomy with or without labyrinthectomy, the new, perimodiolar malleable electrode array could successfully be implanted in all four patients. Six months after surgery, the averaged sound field thresholds to pulsed narrowband noise in the four patients were 36, 28, 41, and 35 dB HL, and the word recognitions scores for monosyllables at 65 dB SPL were 65, 80, 70, and 25% (one patient non-German speaking). CONCLUSION: The surgical evaluation demonstrated the feasibility of cochlear implantation with the new, perimodiolar malleable electrode array after subtotal cochleoectomy. The audiological results were comparable to those achieved with another commercially available type of perimodiolar electrode array from a different manufacturer applied in patients with ILS.
format Online
Article
Text
id pubmed-7826316
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-78263162021-02-11 Hearing rehabilitation after subtotal cochleoectomy using a new, perimodiolar malleable cochlear implant electrode array: a preliminary report Plontke, Stefan K. Fröhlich, Laura Cozma, Sebastian Koitschev, Assen Reimann, Katrin Weiß, Rainer Götze, Gerrit Seiwerth, Ingmar Kösling, Sabrina Rahne, Torsten Eur Arch Otorhinolaryngol Otology PURPOSE: We here report about the first surgical experience and audiological outcome using a new, perimodiolar malleable cochlear implant electrode array for hearing rehabilitation after subtotal cochleoectomy for intralabyrinthine schwannoma (ILS). METHOD: Based on a cochlear implant with MRI compatibility of the magnet in the receiver coil up to 3 T, a cochlear implant electrode array was developed that is malleable and can be placed perimodiolar after tumor removal from the cochlea via subtotal cochleoectomy. Malleability was reached by incorporating a nitinol wire into the silicone of the electrode array lateral to the electrode contacts. The custom-made device was implanted in four patients with intracochlear, intravestibulocochlear or transmodiolar schwannomas. Outcome was assessed by evaluating the feasibility of the surgical procedure and by measuring sound field thresholds and word recognition scores. RESULTS: After complete or partial tumor removal via subtotal cochleoectomy with or without labyrinthectomy, the new, perimodiolar malleable electrode array could successfully be implanted in all four patients. Six months after surgery, the averaged sound field thresholds to pulsed narrowband noise in the four patients were 36, 28, 41, and 35 dB HL, and the word recognitions scores for monosyllables at 65 dB SPL were 65, 80, 70, and 25% (one patient non-German speaking). CONCLUSION: The surgical evaluation demonstrated the feasibility of cochlear implantation with the new, perimodiolar malleable electrode array after subtotal cochleoectomy. The audiological results were comparable to those achieved with another commercially available type of perimodiolar electrode array from a different manufacturer applied in patients with ILS. Springer Berlin Heidelberg 2020-06-05 2021 /pmc/articles/PMC7826316/ /pubmed/32504199 http://dx.doi.org/10.1007/s00405-020-06098-1 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Otology
Plontke, Stefan K.
Fröhlich, Laura
Cozma, Sebastian
Koitschev, Assen
Reimann, Katrin
Weiß, Rainer
Götze, Gerrit
Seiwerth, Ingmar
Kösling, Sabrina
Rahne, Torsten
Hearing rehabilitation after subtotal cochleoectomy using a new, perimodiolar malleable cochlear implant electrode array: a preliminary report
title Hearing rehabilitation after subtotal cochleoectomy using a new, perimodiolar malleable cochlear implant electrode array: a preliminary report
title_full Hearing rehabilitation after subtotal cochleoectomy using a new, perimodiolar malleable cochlear implant electrode array: a preliminary report
title_fullStr Hearing rehabilitation after subtotal cochleoectomy using a new, perimodiolar malleable cochlear implant electrode array: a preliminary report
title_full_unstemmed Hearing rehabilitation after subtotal cochleoectomy using a new, perimodiolar malleable cochlear implant electrode array: a preliminary report
title_short Hearing rehabilitation after subtotal cochleoectomy using a new, perimodiolar malleable cochlear implant electrode array: a preliminary report
title_sort hearing rehabilitation after subtotal cochleoectomy using a new, perimodiolar malleable cochlear implant electrode array: a preliminary report
topic Otology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7826316/
https://www.ncbi.nlm.nih.gov/pubmed/32504199
http://dx.doi.org/10.1007/s00405-020-06098-1
work_keys_str_mv AT plontkestefank hearingrehabilitationaftersubtotalcochleoectomyusinganewperimodiolarmalleablecochlearimplantelectrodearrayapreliminaryreport
AT frohlichlaura hearingrehabilitationaftersubtotalcochleoectomyusinganewperimodiolarmalleablecochlearimplantelectrodearrayapreliminaryreport
AT cozmasebastian hearingrehabilitationaftersubtotalcochleoectomyusinganewperimodiolarmalleablecochlearimplantelectrodearrayapreliminaryreport
AT koitschevassen hearingrehabilitationaftersubtotalcochleoectomyusinganewperimodiolarmalleablecochlearimplantelectrodearrayapreliminaryreport
AT reimannkatrin hearingrehabilitationaftersubtotalcochleoectomyusinganewperimodiolarmalleablecochlearimplantelectrodearrayapreliminaryreport
AT weißrainer hearingrehabilitationaftersubtotalcochleoectomyusinganewperimodiolarmalleablecochlearimplantelectrodearrayapreliminaryreport
AT gotzegerrit hearingrehabilitationaftersubtotalcochleoectomyusinganewperimodiolarmalleablecochlearimplantelectrodearrayapreliminaryreport
AT seiwerthingmar hearingrehabilitationaftersubtotalcochleoectomyusinganewperimodiolarmalleablecochlearimplantelectrodearrayapreliminaryreport
AT koslingsabrina hearingrehabilitationaftersubtotalcochleoectomyusinganewperimodiolarmalleablecochlearimplantelectrodearrayapreliminaryreport
AT rahnetorsten hearingrehabilitationaftersubtotalcochleoectomyusinganewperimodiolarmalleablecochlearimplantelectrodearrayapreliminaryreport