Hearing rehabilitation after subtotal cochleoectomy using a new, perimodiolar malleable cochlear implant electrode array: a preliminary report
PURPOSE: We here report about the first surgical experience and audiological outcome using a new, perimodiolar malleable cochlear implant electrode array for hearing rehabilitation after subtotal cochleoectomy for intralabyrinthine schwannoma (ILS). METHOD: Based on a cochlear implant with MRI compa...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7826316/ https://www.ncbi.nlm.nih.gov/pubmed/32504199 http://dx.doi.org/10.1007/s00405-020-06098-1 |
_version_ | 1783640511520702464 |
---|---|
author | Plontke, Stefan K. Fröhlich, Laura Cozma, Sebastian Koitschev, Assen Reimann, Katrin Weiß, Rainer Götze, Gerrit Seiwerth, Ingmar Kösling, Sabrina Rahne, Torsten |
author_facet | Plontke, Stefan K. Fröhlich, Laura Cozma, Sebastian Koitschev, Assen Reimann, Katrin Weiß, Rainer Götze, Gerrit Seiwerth, Ingmar Kösling, Sabrina Rahne, Torsten |
author_sort | Plontke, Stefan K. |
collection | PubMed |
description | PURPOSE: We here report about the first surgical experience and audiological outcome using a new, perimodiolar malleable cochlear implant electrode array for hearing rehabilitation after subtotal cochleoectomy for intralabyrinthine schwannoma (ILS). METHOD: Based on a cochlear implant with MRI compatibility of the magnet in the receiver coil up to 3 T, a cochlear implant electrode array was developed that is malleable and can be placed perimodiolar after tumor removal from the cochlea via subtotal cochleoectomy. Malleability was reached by incorporating a nitinol wire into the silicone of the electrode array lateral to the electrode contacts. The custom-made device was implanted in four patients with intracochlear, intravestibulocochlear or transmodiolar schwannomas. Outcome was assessed by evaluating the feasibility of the surgical procedure and by measuring sound field thresholds and word recognition scores. RESULTS: After complete or partial tumor removal via subtotal cochleoectomy with or without labyrinthectomy, the new, perimodiolar malleable electrode array could successfully be implanted in all four patients. Six months after surgery, the averaged sound field thresholds to pulsed narrowband noise in the four patients were 36, 28, 41, and 35 dB HL, and the word recognitions scores for monosyllables at 65 dB SPL were 65, 80, 70, and 25% (one patient non-German speaking). CONCLUSION: The surgical evaluation demonstrated the feasibility of cochlear implantation with the new, perimodiolar malleable electrode array after subtotal cochleoectomy. The audiological results were comparable to those achieved with another commercially available type of perimodiolar electrode array from a different manufacturer applied in patients with ILS. |
format | Online Article Text |
id | pubmed-7826316 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-78263162021-02-11 Hearing rehabilitation after subtotal cochleoectomy using a new, perimodiolar malleable cochlear implant electrode array: a preliminary report Plontke, Stefan K. Fröhlich, Laura Cozma, Sebastian Koitschev, Assen Reimann, Katrin Weiß, Rainer Götze, Gerrit Seiwerth, Ingmar Kösling, Sabrina Rahne, Torsten Eur Arch Otorhinolaryngol Otology PURPOSE: We here report about the first surgical experience and audiological outcome using a new, perimodiolar malleable cochlear implant electrode array for hearing rehabilitation after subtotal cochleoectomy for intralabyrinthine schwannoma (ILS). METHOD: Based on a cochlear implant with MRI compatibility of the magnet in the receiver coil up to 3 T, a cochlear implant electrode array was developed that is malleable and can be placed perimodiolar after tumor removal from the cochlea via subtotal cochleoectomy. Malleability was reached by incorporating a nitinol wire into the silicone of the electrode array lateral to the electrode contacts. The custom-made device was implanted in four patients with intracochlear, intravestibulocochlear or transmodiolar schwannomas. Outcome was assessed by evaluating the feasibility of the surgical procedure and by measuring sound field thresholds and word recognition scores. RESULTS: After complete or partial tumor removal via subtotal cochleoectomy with or without labyrinthectomy, the new, perimodiolar malleable electrode array could successfully be implanted in all four patients. Six months after surgery, the averaged sound field thresholds to pulsed narrowband noise in the four patients were 36, 28, 41, and 35 dB HL, and the word recognitions scores for monosyllables at 65 dB SPL were 65, 80, 70, and 25% (one patient non-German speaking). CONCLUSION: The surgical evaluation demonstrated the feasibility of cochlear implantation with the new, perimodiolar malleable electrode array after subtotal cochleoectomy. The audiological results were comparable to those achieved with another commercially available type of perimodiolar electrode array from a different manufacturer applied in patients with ILS. Springer Berlin Heidelberg 2020-06-05 2021 /pmc/articles/PMC7826316/ /pubmed/32504199 http://dx.doi.org/10.1007/s00405-020-06098-1 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Otology Plontke, Stefan K. Fröhlich, Laura Cozma, Sebastian Koitschev, Assen Reimann, Katrin Weiß, Rainer Götze, Gerrit Seiwerth, Ingmar Kösling, Sabrina Rahne, Torsten Hearing rehabilitation after subtotal cochleoectomy using a new, perimodiolar malleable cochlear implant electrode array: a preliminary report |
title | Hearing rehabilitation after subtotal cochleoectomy using a new, perimodiolar malleable cochlear implant electrode array: a preliminary report |
title_full | Hearing rehabilitation after subtotal cochleoectomy using a new, perimodiolar malleable cochlear implant electrode array: a preliminary report |
title_fullStr | Hearing rehabilitation after subtotal cochleoectomy using a new, perimodiolar malleable cochlear implant electrode array: a preliminary report |
title_full_unstemmed | Hearing rehabilitation after subtotal cochleoectomy using a new, perimodiolar malleable cochlear implant electrode array: a preliminary report |
title_short | Hearing rehabilitation after subtotal cochleoectomy using a new, perimodiolar malleable cochlear implant electrode array: a preliminary report |
title_sort | hearing rehabilitation after subtotal cochleoectomy using a new, perimodiolar malleable cochlear implant electrode array: a preliminary report |
topic | Otology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7826316/ https://www.ncbi.nlm.nih.gov/pubmed/32504199 http://dx.doi.org/10.1007/s00405-020-06098-1 |
work_keys_str_mv | AT plontkestefank hearingrehabilitationaftersubtotalcochleoectomyusinganewperimodiolarmalleablecochlearimplantelectrodearrayapreliminaryreport AT frohlichlaura hearingrehabilitationaftersubtotalcochleoectomyusinganewperimodiolarmalleablecochlearimplantelectrodearrayapreliminaryreport AT cozmasebastian hearingrehabilitationaftersubtotalcochleoectomyusinganewperimodiolarmalleablecochlearimplantelectrodearrayapreliminaryreport AT koitschevassen hearingrehabilitationaftersubtotalcochleoectomyusinganewperimodiolarmalleablecochlearimplantelectrodearrayapreliminaryreport AT reimannkatrin hearingrehabilitationaftersubtotalcochleoectomyusinganewperimodiolarmalleablecochlearimplantelectrodearrayapreliminaryreport AT weißrainer hearingrehabilitationaftersubtotalcochleoectomyusinganewperimodiolarmalleablecochlearimplantelectrodearrayapreliminaryreport AT gotzegerrit hearingrehabilitationaftersubtotalcochleoectomyusinganewperimodiolarmalleablecochlearimplantelectrodearrayapreliminaryreport AT seiwerthingmar hearingrehabilitationaftersubtotalcochleoectomyusinganewperimodiolarmalleablecochlearimplantelectrodearrayapreliminaryreport AT koslingsabrina hearingrehabilitationaftersubtotalcochleoectomyusinganewperimodiolarmalleablecochlearimplantelectrodearrayapreliminaryreport AT rahnetorsten hearingrehabilitationaftersubtotalcochleoectomyusinganewperimodiolarmalleablecochlearimplantelectrodearrayapreliminaryreport |